Danfoss

134F2984 | Danfoss | Frequency Converter

SKU 134F2984

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 134F2984

  • Country of origin:United States

  • Product Type: FC-360H30KT4E20H2XXCDXXSXXXXAXBX Frequency Converter

  • Payment: T/T, Western Union

  • Weight: 24320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Danfoss 134F2984 (FC-360H30KT4E20H2XXCDXXSXXXXAXBX) VLT AutomationDrive is a high-capacity frequency converter engineered for heavy-duty industrial motor control. Capable of handling a 30 kW (40 HP) load, this unit is specifically designed for high-overload applications in sectors such as manufacturing, large-scale pumping, and material processing. By providing precise speed regulation and reducing mechanical stress during high-torque startup phases, the drive significantly mitigates equipment wear and prevents unplanned system downtime. Its chassis-based IP20 architecture and factory-applied conformal coating ensure reliability in demanding plant environments, making it a critical asset for maintaining continuous industrial production.

Technical Configuration

The 134F2984 is configured as a robust power conversion solution for 380-480 VAC three-phase grids. The unit features an integrated Class A2 RFI filter to minimize electromagnetic interference within the facility. Unlike smaller drives, this model incorporates a DC load-sharing (Mains Option D) interface, allowing for efficient energy distribution across multi-drive industrial architectures. The hardware is supplied without an internal brake chopper or local display, focusing on high-efficiency performance and seamless integration into automated PLC control systems via its standard control card. The PCB is conformal coated ("C") to protect internal components against oxidation and contaminants, ensuring a prolonged operational lifecycle.

Technical Specifications

Feature Specification
Model 134F2984
Brand Danfoss
Series VLT AutomationDrive FC-360
Power Rating 30 kW / 40 HP
Mains Voltage 380 - 480 VAC (3-phase)
Enclosure Class IP20
RFI Filter Class A2
PCB Coating Coated
Mains Option Loadsharing
Brake Chopper None
Net Weight 24.32 kg
Shipping Weight 26 kg

FAQs

What is the purpose of the Loadsharing (Mains Option D) capability?

Loadsharing enables the DC bus of the drive to be linked with other compatible drives, allowing the system to share regenerated energy between units, which reduces power consumption and heat output.

Since this model has no brake chopper, how is regenerative energy managed?

Without an internal brake chopper, this drive is optimized for applications that do not require high-energy dynamic braking. If the process requires fast deceleration, an external brake module must be integrated via the DC bus.

Is a Local Control Panel (LCP) required for configuration?

This unit is supplied without an LCP or blind cover. Commissioning and parameter monitoring are intended to be performed using an external LCP or via serial communication through the control card.

How does the conformal coating improve durability in chemical processing plants?

The conformal coating creates a physical barrier against corrosive gases and airborne pollutants, preventing short circuits and trace oxidation on the circuit board that typically cause failures in aggressive industrial climates.

Installation and Operational Guidelines

  • Heat Management and Clearance: Given the 30 kW capacity, this drive generates significant thermal energy. It is mandatory to install the unit in an enclosure with filtered forced-air cooling. Maintain at least 200 mm of clearance above and below the drive to ensure the internal cooling fans can circulate air effectively through the heatsink.
  • Grounding Requirements: To ensure compliance with RFI Class A2 standards and protect the internal sensitive electronics, the drive chassis must be connected to a high-integrity industrial earth. Use a short, low-impedance ground cable and ensure the motor cable shield is terminated directly to the drive frame using a 360-degree conductive clamp.
  • Safety and Discharge Time: Due to the large capacitance in the 30 kW frame size, always wait at least 15 minutes after disconnecting the mains power before performing any internal maintenance or terminal adjustments. Always verify that the DC bus voltage has dropped to a safe level (under 50 VDC) before proceeding.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.