ABB

ABB 1SFA898116R7000 PSTX470-600-70 PSTX Softstarter

SKU 1SFA898116R7000 PSTX470-600-70

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB
  • Product No.: 1SFA898116R7000 PSTX470-600-70
  • Origin Sweden
  • Product Type: Softstarter
  • Barcode: 85371091
  • Payment: T/T, Western Union
  • Weight: 25.0 kg
  • Dimensions: 361 x 493 x 282 mm (W x H x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB 1SFA898116R7000 PSTX470-600-70 PSTX Softstarter

Quantity

Product Description

Description

The ABB PSTX470-600-70 is a PSTX series softstarter for medium- and large-size three-phase motors.

The unit has a rated operational current of 470 A in an in-line connection. Its main operating voltage range is 208 to 600 VAC.

The rated control supply voltage is 100 to 250 VAC at 50/60 Hz. The control circuit voltage is 24 VDC.

The PSTX470-600-70 provides three-phase controlled soft starting and stopping through voltage or torque ramps. An integrated bypass reduces losses during normal motor operation.

The unit also supports inside-delta connection, with a rated operational current of 814 A. Motor ratings reach 315 kW at 500 V in-line and 600 kW at 500 V inside delta.

Built-in functions include electronic overload protection, current limiting, kick start, motor heating, pump cleaning, jog, braking, sequence start, diagnostics, and emergency/fire pump mode.

Features

  • PSTX series softstarter

  • 470 A rated operational current in-line

  • 814 A rated operational current inside delta

  • 208 to 600 VAC main operating voltage

  • 100 to 250 VAC control supply

  • 24 VDC control circuit voltage

  • Integrated bypass

  • Three-phase motor control

  • Soft start by voltage ramp

  • Soft start by torque control

  • Soft stop by voltage ramp

  • Soft stop by torque control

  • Built-in electronic overload protection

  • Adjustable current limit

  • Kick start function

  • Motor heating

  • Pump cleaning

  • Jog forward and reverse

  • Dynamic brake

  • Standstill brake

  • Sequence start

  • Emergency mode

  • Integrated diagnostics

  • Detachable full graphic display

  • Built-in Modbus RTU communication

  • Optional industrial Ethernet and fieldbus communication

Applications

  • Pumps

  • Fans and blowers

  • Compressors

  • Conveyors

  • Industrial process machinery

  • Medium- and large-size three-phase motors

  • Water and wastewater systems

  • HVAC systems

  • Material handling equipment

  • High-power motor starting applications

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 1SFA898116R7000
Type Designation PSTX470-600-70
Product Family PSTX
Product Type Softstarter
Rated Operational Voltage 208 to 600 VAC
Rated Frequency 50/60 Hz
Rated Operational Current, In-Line 470 A
Rated Operational Current, Inside Delta 814 A
Rated Control Supply Voltage 100 to 250 VAC
Rated Control Circuit Voltage 24 VDC
Service Factor 100%
Starting Capacity at Maximum Ie 4 x Ie for 10 s
Ramp Time 1 to 120 s
Initial Voltage During Start 10 to 99%
Inside Delta Connection Supported
Integrated Electronic Overload Yes
Integrated Bypass Yes

ABB identifies the exact model as PSTX470-600-70, Product ID 1SFA898116R7000, rated for 470 A and 208 to 600 VAC.

Motor Ratings

Supply Voltage In-Line Connection Inside Delta
230 V 132 kW 250 kW
400 V 250 kW 450 kW
500 V 315 kW 600 kW

The exact ABB technical data gives 470 A in-line and 814 A inside delta.

Control and Protection Functions

Function Availability
Auto Phase Sequence Detection Yes
Automatic Restart Yes
Current Limit Yes
Current Limit Ramp Yes
Dual Current Limit Yes
Dynamic Brake Yes
Electronic Overload Yes
Emergency Mode Yes
Event Log Yes
Full Voltage Start Yes
Jog Forward / Reverse Yes
Kick Start Yes
Limp Mode Yes
Motor Heating Yes
Pump Cleaning Yes
Sequence Start Yes
Torque Limit Yes
Voltage Sag Detection Yes
Real-Time Clock Yes

Protection Functions

  • Bypass open protection

  • Current imbalance protection

  • Current underload protection

  • Dual overload protection

  • Earth fault / ground fault protection

  • Electronic overload protection

  • Fieldbus failure protection

  • HMI failure protection

  • Locked rotor protection

  • Overvoltage protection

  • Phase reversal protection

  • PT100 connection

  • PTC connection

  • Too-long start protection

  • Undervoltage protection

  • Voltage imbalance protection

ABB lists these protection and motor-control functions as standard capabilities of the PSTX470-600-70.

Communication

Interface / Protocol Availability
Modbus RTU Built-in
Modbus TCP Supported through optional communication module
Ethernet/IP Supported through optional communication module
PROFINET Supported through optional communication module
PROFIBUS Supported through optional communication module
EtherCAT Supported through optional communication module
DeviceNet Supported
CANopen Supported
BACnet/IP Supported
BACnet MS/TP Supported

The PSTX platform provides built-in Modbus RTU and supports additional protocols through optional Anybus or fieldbus modules.

Mechanical Data

Parameter Specification
Width 361 mm
Height 493 mm
Depth 282 mm
Net Weight 25 kg
Main Circuit Terminal Busbar
Main Circuit Hole Diameter 8.5 mm
Main Circuit Tightening Torque 35 N·m

ABB provides exact product dimensions of 361 x 493 x 282 mm and a net weight of 25 kg.

Packaging Data

Parameter Specification
Package Width 470 mm
Package Depth 381 mm
Package Height 650 mm
Gross Weight 29 kg
Package Quantity 1 piece

The ABB product sheet lists the package as 470 x 381 x 650 mm with a gross weight of 29 kg.

Environmental

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +70 degC
Main Terminal Protection IP00
RoHS EU Directive 2011/65/EU and 2015/863
ABB EcoSolutions Yes
Recyclability Rate 83.6%

Installation & Commissioning

  • Verify the complete Product ID 1SFA898116R7000 before replacement.

  • Confirm motor current and supply voltage against the selected connection method.

  • Distinguish between in-line and inside-delta ratings during sizing.

  • Verify the 100 to 250 VAC control supply before energizing the unit.

  • Confirm the 24 VDC control circuit wiring.

  • Set motor overload and current-limit parameters for the connected motor.

  • Verify start, stop, bypass, and protection functions during commissioning.

  • Confirm fieldbus settings where optional communication modules are installed.

Replacement Notes

  • Match the exact PSTX470-600-70 type designation.

  • Confirm in-line or inside-delta connection before replacement.

  • Preserve motor protection, ramp, communication, and control settings.

  • Optional fieldbus modules should be checked separately from the base softstarter.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the ABB PSTX470-600-70?
The ABB PSTX470-600-70 is a PSTX softstarter rated for 470 A in-line operation and 208 to 600 VAC main circuit voltage.
What is the inside-delta rating of the ABB PSTX470-600-70?
The ABB PSTX470-600-70 is rated for 814 A in an inside-delta connection.
What motor power can the PSTX470-600-70 control?
At 500 V, the ABB PSTX470-600-70 is rated for 315 kW in-line and 600 kW in an inside-delta connection.
What control voltage does the PSTX470-600-70 use?
The ABB PSTX470-600-70 uses a rated control supply of 100 to 250 VAC at 50/60 Hz and a 24 VDC control circuit.
Does the ABB PSTX470-600-70 have an integrated bypass?
Yes. The ABB PSTX470-600-70 includes an integrated bypass for reduced losses during normal motor operation.
Which communication protocols are supported by the PSTX470-600-70?
The ABB PSTX470-600-70 includes Modbus RTU and can support additional protocols such as PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, EtherCAT, DeviceNet, CANopen, and BACnet through compatible communication options.
Reviews

1SFA898116R7000 PSTX470-600-70

Stock & lead time on request

Call
1 of 2

ABB 1SFA898116R7000 PSTX470-600-70 PSTX Softstarter

Only 10 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 1SFA898116R7000 PSTX470-600-70

  • Country of origin:Sweden

  • Product Type: Softstarter

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 25000g

  • Dimensions: 361 x 493 x 282 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ABB PSTX470-600-70 is a PSTX series softstarter for medium- and large-size three-phase motors.

The unit has a rated operational current of 470 A in an in-line connection. Its main operating voltage range is 208 to 600 VAC.

The rated control supply voltage is 100 to 250 VAC at 50/60 Hz. The control circuit voltage is 24 VDC.

The PSTX470-600-70 provides three-phase controlled soft starting and stopping through voltage or torque ramps. An integrated bypass reduces losses during normal motor operation.

The unit also supports inside-delta connection, with a rated operational current of 814 A. Motor ratings reach 315 kW at 500 V in-line and 600 kW at 500 V inside delta.

Built-in functions include electronic overload protection, current limiting, kick start, motor heating, pump cleaning, jog, braking, sequence start, diagnostics, and emergency/fire pump mode.

Features

  • PSTX series softstarter

  • 470 A rated operational current in-line

  • 814 A rated operational current inside delta

  • 208 to 600 VAC main operating voltage

  • 100 to 250 VAC control supply

  • 24 VDC control circuit voltage

  • Integrated bypass

  • Three-phase motor control

  • Soft start by voltage ramp

  • Soft start by torque control

  • Soft stop by voltage ramp

  • Soft stop by torque control

  • Built-in electronic overload protection

  • Adjustable current limit

  • Kick start function

  • Motor heating

  • Pump cleaning

  • Jog forward and reverse

  • Dynamic brake

  • Standstill brake

  • Sequence start

  • Emergency mode

  • Integrated diagnostics

  • Detachable full graphic display

  • Built-in Modbus RTU communication

  • Optional industrial Ethernet and fieldbus communication

Applications

  • Pumps

  • Fans and blowers

  • Compressors

  • Conveyors

  • Industrial process machinery

  • Medium- and large-size three-phase motors

  • Water and wastewater systems

  • HVAC systems

  • Material handling equipment

  • High-power motor starting applications

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 1SFA898116R7000
Type Designation PSTX470-600-70
Product Family PSTX
Product Type Softstarter
Rated Operational Voltage 208 to 600 VAC
Rated Frequency 50/60 Hz
Rated Operational Current, In-Line 470 A
Rated Operational Current, Inside Delta 814 A
Rated Control Supply Voltage 100 to 250 VAC
Rated Control Circuit Voltage 24 VDC
Service Factor 100%
Starting Capacity at Maximum Ie 4 x Ie for 10 s
Ramp Time 1 to 120 s
Initial Voltage During Start 10 to 99%
Inside Delta Connection Supported
Integrated Electronic Overload Yes
Integrated Bypass Yes

ABB identifies the exact model as PSTX470-600-70, Product ID 1SFA898116R7000, rated for 470 A and 208 to 600 VAC.

Motor Ratings

Supply Voltage In-Line Connection Inside Delta
230 V 132 kW 250 kW
400 V 250 kW 450 kW
500 V 315 kW 600 kW

The exact ABB technical data gives 470 A in-line and 814 A inside delta.

Control and Protection Functions

Function Availability
Auto Phase Sequence Detection Yes
Automatic Restart Yes
Current Limit Yes
Current Limit Ramp Yes
Dual Current Limit Yes
Dynamic Brake Yes
Electronic Overload Yes
Emergency Mode Yes
Event Log Yes
Full Voltage Start Yes
Jog Forward / Reverse Yes
Kick Start Yes
Limp Mode Yes
Motor Heating Yes
Pump Cleaning Yes
Sequence Start Yes
Torque Limit Yes
Voltage Sag Detection Yes
Real-Time Clock Yes

Protection Functions

  • Bypass open protection

  • Current imbalance protection

  • Current underload protection

  • Dual overload protection

  • Earth fault / ground fault protection

  • Electronic overload protection

  • Fieldbus failure protection

  • HMI failure protection

  • Locked rotor protection

  • Overvoltage protection

  • Phase reversal protection

  • PT100 connection

  • PTC connection

  • Too-long start protection

  • Undervoltage protection

  • Voltage imbalance protection

ABB lists these protection and motor-control functions as standard capabilities of the PSTX470-600-70.

Communication

Interface / Protocol Availability
Modbus RTU Built-in
Modbus TCP Supported through optional communication module
Ethernet/IP Supported through optional communication module
PROFINET Supported through optional communication module
PROFIBUS Supported through optional communication module
EtherCAT Supported through optional communication module
DeviceNet Supported
CANopen Supported
BACnet/IP Supported
BACnet MS/TP Supported

The PSTX platform provides built-in Modbus RTU and supports additional protocols through optional Anybus or fieldbus modules.

Mechanical Data

Parameter Specification
Width 361 mm
Height 493 mm
Depth 282 mm
Net Weight 25 kg
Main Circuit Terminal Busbar
Main Circuit Hole Diameter 8.5 mm
Main Circuit Tightening Torque 35 N·m

ABB provides exact product dimensions of 361 x 493 x 282 mm and a net weight of 25 kg.

Packaging Data

Parameter Specification
Package Width 470 mm
Package Depth 381 mm
Package Height 650 mm
Gross Weight 29 kg
Package Quantity 1 piece

The ABB product sheet lists the package as 470 x 381 x 650 mm with a gross weight of 29 kg.

Environmental

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +70 degC
Main Terminal Protection IP00
RoHS EU Directive 2011/65/EU and 2015/863
ABB EcoSolutions Yes
Recyclability Rate 83.6%

Installation & Commissioning

  • Verify the complete Product ID 1SFA898116R7000 before replacement.

  • Confirm motor current and supply voltage against the selected connection method.

  • Distinguish between in-line and inside-delta ratings during sizing.

  • Verify the 100 to 250 VAC control supply before energizing the unit.

  • Confirm the 24 VDC control circuit wiring.

  • Set motor overload and current-limit parameters for the connected motor.

  • Verify start, stop, bypass, and protection functions during commissioning.

  • Confirm fieldbus settings where optional communication modules are installed.

Replacement Notes

  • Match the exact PSTX470-600-70 type designation.

  • Confirm in-line or inside-delta connection before replacement.

  • Preserve motor protection, ramp, communication, and control settings.

  • Optional fieldbus modules should be checked separately from the base softstarter.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB 1SFA898116R7000 PSTX470-600-70 PSTX Softstarter

What is the ABB PSTX470-600-70?

The ABB PSTX470-600-70 is a PSTX softstarter rated for 470 A in-line operation and 208 to 600 VAC main circuit voltage.

What is the inside-delta rating of the ABB PSTX470-600-70?

The ABB PSTX470-600-70 is rated for 814 A in an inside-delta connection.

What motor power can the PSTX470-600-70 control?

At 500 V, the ABB PSTX470-600-70 is rated for 315 kW in-line and 600 kW in an inside-delta connection.

What control voltage does the PSTX470-600-70 use?

The ABB PSTX470-600-70 uses a rated control supply of 100 to 250 VAC at 50/60 Hz and a 24 VDC control circuit.

Does the ABB PSTX470-600-70 have an integrated bypass?

Yes. The ABB PSTX470-600-70 includes an integrated bypass for reduced losses during normal motor operation.

Which communication protocols are supported by the PSTX470-600-70?

The ABB PSTX470-600-70 includes Modbus RTU and can support additional protocols such as PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, EtherCAT, DeviceNet, CANopen, and BACnet through compatible communication options.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...