ABB

ABB 3AXD50000814077 ACS180-04S-12A6-4 ACS180 Variable Frequency Drive

SKU ACS180-04S-12A6-4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: ACS180-04S-12A6-4

  • Country of origin:Sweden

  • Product Type: Variable Frequency Drives

  • Barcode: 85044085

  • Payment: T/T, Western Union

  • Weight: 2010g

  • Dimensions: 143 mm x 230 mm x 120 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for precise motor control in compact machinery applications, the ABB 3AXD50000814077 (model ACS180-04S-12A6-4) is a high-efficiency, low-voltage AC machinery drive module. Operating within the reliable ACS180 series, this variable frequency drive (VFD) delivers consistent speed and torque regulation for three-phase AC motors. It is designed to optimize energy consumption and process performance in space-constrained installations.

The unit features integrated Modbus RTU communication, allowing for straightforward integration into centralized PLC environments and industrial networks. Its robust architecture makes it well-suited for demanding mechanical environments, providing built-in protection mechanisms that safeguard both the drive and the connected motor from electrical faults.

Features

  • Space-saving mechanical design optimized for cabinet installation.
  • Embedded Modbus RTU serial communication interface.
  • Supports precise scalar and vector control modes.
  • Integrated protection functions including overcurrent, overvoltage, and thermal overload monitoring.
  • Simple commissioning parameters for fast configuration and deployment.

Applications

  • Industrial pump and water circulation systems.
  • HVAC ventilation fans and blower systems.
  • Air and gas compressors.
  • Material handling conveyors and automated feeders.
  • Agitators, mixers, and industrial winders.

Technical Specifications

Manufacturer ABB
Part Number / Model ACS180-04S-12A6-4
Product ID 3AXD50000814077
Product Series ACS180
Drive Type Low-Voltage AC Machinery Drive
Nominal Output Power 5.5 kW
Rated Current 12.6 A
Input Voltage 400 V AC (Three-Phase)
Communication Protocol Modbus RTU
Dimensions (W x H x D) 143 mm x 230 mm x 120 mm
Weight 2.01 kg
HS Code 85044086

Installation Guidelines

  • Mounting: Install the drive vertically inside a clean, dust-free control cabinet to ensure optimal cooling.
  • Clearance: Maintain specified minimum clearances above and below the drive module to allow unrestricted airflow through the heatsink.
  • Wiring: Utilize shielded motor cabling to suppress electromagnetic interference (EMI) and comply with local EMC regulations.
  • Grounding: Ensure the drive's protective earth (PE) terminal is securely bonded to the main system ground busbar.

Compliance and Certifications

  • RoHS Compliant

FAQ

What is the power rating of the ABB ACS180-04S-12A6-4 drive?

The drive has a nominal power rating of 5.5 kW with a rated current of 12.6 A at a 400 V input.

Which communication interfaces are built into the 3AXD50000814077 VFD?

The drive includes integrated Modbus RTU serial communication as standard for industrial control system integration.

What are the physical dimensions and weight of this module?

The module measures 143 mm in width, 230 mm in height, and 120 mm in depth, and has a net weight of 2.01 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.