ABB ACS580-01-033A-4 ACS580 Variable Speed Drive

ABB ACS580-01-033A-4 ACS580 Variable Speed Drive

Only 8 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: ACS580-01-033A-4

  • Country of origin:Sweden

  • Product Type: Variable Frequency Drives

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12250g

  • Dimensions: 490 mm x 220 mm x 260 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Optimizing process control and energy efficiency in industrial pumping, ventilation, and mechanical conveying setups, the ABB ACS580-01-033A-4 wall-mounted variable speed drive delivers precise performance within the ACS580 series. This three-phase drive module is engineered to operate directly out of the box, offering plug-and-play motor control without extensive parameter setups. Equipped with an integrated control panel and built-in harmonic mitigation technology, the ABB ACS580-01-033A-4 maintains high electrical efficiency and reliable system uptime in demanding process environments.

Features

  • Integrated Harmonics Reduction: Built-in variable choke technology minimizes input current harmonics under both partial and full load conditions.
  • All-Compatible Architecture: Features a standardized parameter structure and user interface compatible with wider ABB drive portfolios.
  • Safe Torque Off (STO): Built-in dual-channel STO safety function complies with SIL 3 / PL e requirements.
  • Embedded Modbus RTU: Integrated EIA-485 interface supports direct fieldbus communication without external gateway modules.
  • Optimized Energy Monitoring: Built-in calculators track energy consumption, savings in local currency, and CO2 reduction metrics.

Applications

  • Centrifugal pumps and booster stations in water/wastewater treatment plants.
  • Industrial supply and exhaust fans in HVAC and ventilation systems.
  • Conveyor systems and material handling machinery requiring precise speed ramps.
  • Compressor control for refrigeration and manufacturing process air lines.

Technical Specifications

Parameter Value
Manufacturer ABB
Model Code ACS580-01-033A-4
Frame Size R3
Input Voltage Range 3-phase 380 to 480 VAC (+10% / -15%)
Nominal Output Current 33.0 A (at 400V, light-duty load)
Heavy-Duty Output Current 25.0 A (at 400V)
Power Rating (Light-Duty) 15.0 kW (20 HP)
Power Rating (Heavy-Duty) 11.0 kW (15 HP)
Enclosure Rating IP21 (UL Type 1)
Mains Frequency 50 / 60 Hz (+/- 5%)
Control Connection Embedded Modbus RTU / Option slot for Fieldbus adapters
Operating Temperature -15 to +40 degC (no derating) / up to +50 degC (with derating)
Logistics Weight 12.25 kg
Commodity Code 85371091
Package Dimensions (Calculated) 490 mm x 220 mm x 260 mm

Connections and Interfaces

Terminal Block Signal / Circuit Assignment
L1, L2, L3 3-phase AC main input supply
U2, V2, W2 Motor output connections
UDC+, UDC- DC bus connections (for external braking units)
DI1 to DI6 Digital inputs (programmable, PNP/NPN config)
AI1, AI2 Analog inputs (voltage 0-10V or current 0-20mA selectable)
RO1, RO2, RO3 Relay outputs (250 VAC / 30 VDC, max 2 A)
OUT1, OUT2 (STO) Safe Torque Off dual-channel safety loop

Empirical Engineering Insights

To ensure long-term stability and reliable deployment in severe industrial setups, engineers should evaluate key operational limits and design parameters compiled from factory documentation and field deployments.

Alternative Models & Compatibility

The ACS580-01-033A-4 is the standard IP21 (UL Type 1) wall-mounted drive. For environments heavily exposed to dust or moisture, the IP55-rated variant (ACS580-01-033A-4+B056) should be specified. This unit serves as a form-fit-function upgrade path for legacy ACS550-01-031A-4 drives, but panel layouts must account for minor mounting footprint updates and modernized control terminal mapping.

Application Pitfalls & Engineering Notes

For installations inside tight electrical enclosures, the R3 frame size requires at least 200 mm of vertical clearance above and 150 mm below the drive to prevent heat stagnation. Operating the drive above 40 degC triggers an output current derating factor of 1% per additional degC up to a maximum limit of 50 degC.

Commissioning & Wiring Tips

When utilizing the integrated EIA-485 Modbus RTU interface, remember to set the termination switch (J3) to the 'ON' position ONLY on the last physical drive in the network loop. Use shielded, symmetrical three-phase cabling for motor connections to significantly reduce electromagnetic emissions and minimize ground bearing currents.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE RISK

Isolate all power sources and verify complete de-energization on the AC input lines before commencing installation. Wait a minimum of 5 minutes after disconnecting the mains supply to allow the internal DC bus capacitors to discharge below hazardous voltage levels.

1
Mount the R3 frame module vertically onto a flat, non-flammable surface using appropriate M5 mounting screws. Maintain correct clearance profiles.
2
Route the input power, motor, and ground cables through the bottom gland plates. Connect the ground lead securely to the PE terminal.
3
Connect the three-phase AC mains supply to terminals L1, L2, and L3, and the motor leads to U2, V2, and W2. Torque connections to specified nominal limits.
4
Terminate control, feedback, and Safe Torque Off (STO) wiring to the designated low-voltage control terminals. Ensure separation of signal and high-power cables.
5
Reattach the front cover assembly before energizing. Configure the drive settings using the assistant control panel during initial start-up.
Loading product navigation…

What is the primary difference between the ACS580-01-033A-4 and its +B056 version?

The standard ACS580-01-033A-4 has an IP21 / UL Type 1 physical protection rating, suitable for indoor panel mounts. The +B056 suffix signifies an IP55 / UL Type 12 rating, which provides enhanced protection against dust ingress and splashed water.

Can this drive run on single-phase input power?

No, this specific model is designed strictly for three-phase AC input voltages between 380V and 480V. Running it on single-phase power can result in phase loss faults and potential hardware damage.

How do I configure the Safe Torque Off (STO) terminals if I do not use an external safety relay?

If an external safety relay is not used, you must keep the factory-installed jumper wires securely connected across the STO terminals (OUT1 to IN1 and OUT2 to IN2) to allow normal operation.

What is the recommended motor cable length limits for this frame size?

The R3 frame size supports shielded motor cables up to 150 meters without output filters. For longer runs, external du/dt filters are required to protect motor windings from voltage spikes.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...