ABB

ABB DSAX452 5712289-A S800 I/O Remote In / Out Basic Unit

SKU DSAX452 5712289-A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: DSAX452 5712289-A

  • Country of origin:Sweden

  • Product Type: Remote I/O Basic Unit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2520g

  • Dimensions: 23.5 x 21.7 x 8.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB DSAX452 (Ordering Code: 5712289-A) is a modular S800 I/O basic unit designed for distributed control architectures. It functions as a core interface module within process automation systems, managing local input and output signal acquisition and routing them to higher-level controllers via the system bus.

Engineered for DIN-rail mounting within industrial enclosures, the unit integrates directly into ABB process automation infrastructures, supporting hot-swapping capabilities to maintain system availability during maintenance intervals.

Features

  • Modular S800 I/O architecture supporting high-density signal distribution
  • Hot-swappable module design enabling replacement under power without process interruption
  • Direct interface compatibility with ABB Advant and Freelance DCS controllers
  • Comprehensive diagnostic LED indicators for power, status, and communication health

Applications

  • Distributed analog and digital signal aggregation in DCS networks
  • Remote I/O rack expansion in continuous process manufacturing plants
  • Data acquisition and control signal routing in energy and utility infrastructure
  • Brownfield control system retrofits utilizing existing S800 I/O marshalling infrastructure

Technical Specifications

Parameter Specification
Brand ABB
Model / Part Number DSAX452
Ordering Code 5712289-A
Product Family S800 I/O
Product Type Remote I/O Basic Unit
Mounting Type DIN Rail
Country of Origin Sweden

FAQ

What control systems are compatible with the ABB DSAX452 5712289-A?

The DSAX452 is designed for integration with ABB S800 I/O architectures, working natively with controllers such as ABB Advant OCS and Freelance DCS platforms.

Does the DSAX452 support hot-swapping?

Yes, the S800 I/O architecture supports hot-swapping of modules, allowing the DSAX452 to be replaced under power without shutting down the entire I/O station.

What is the primary function of the DSAX452 5712289-A unit?

It serves as a remote I/O basic unit responsible for interfacing field signals with the central distributed control system over the module bus.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...