ABB

ABB Procontic CS31 FPR3327101R1202 ICSK20F1 Binary Input/Output Remote Unit

SKU FPR3327101R0206

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: FPR3327101R0206

  • Country of origin:Sweden

  • Product Type: Binary Input/Output Remote Unit

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 10.20cm x 12.70cm x 15.20cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The FPR3327101R1202 (ICSK 20 F1) is a high-reliability binary input/output remote unit designed for the ABB Procontic CS31 fieldbus system. This distributed I/O module provides 12 digital inputs (24 VDC) and 8 relay outputs, creating a flexible interface between the central PLC and field-level sensors and actuators.

Engineered for seamless integration into the CS31 network, the ICSK 20 F1 supports decentralized automation architectures that reduce wiring complexity and installation costs. Its proven field performance makes it widely used in manufacturing, infrastructure, and process control systems where fast communication and stable response times are essential for reliable operation.

Technical Configuration

The FPR3327101R1202 is designed for modular installation and straightforward diagnostic visibility:

  • Logic Capacity: 12 non-isolated 24 VDC inputs and 8 relay outputs rated up to 250 VAC / 2 A.
  • Visual Interface: LED indicators include 12 input status LEDs (0–11), 8 output status LEDs (0–7), a green Supply LED, and a red Error LED.
  • On-board Diagnostics: Integrated error code reference printed on the front panel, along with a TEST push-button for commissioning and troubleshooting.
  • Mounting Architecture: Designed for installation on an ECZ plug-in base, enabling fast module replacement without disconnecting field wiring.
  • Fieldbus Communication: Optimized for CS31 protocol operation with a configuration time of approximately 452 microseconds.

Technical Specifications

Model ICSK 20 F1 (ICSK20F1)
Order Number FPR3327101R1202
Brand ABB
Fieldbus System Procontic CS31
Power Supply 24 VDC
Current Consumption 0.3 A (Maximum)
Number of Inputs 12 (Nominal 24 VDC)
Number of Outputs 8 (Relay, 250 VAC / 2 A)
Input Delay 5 ms
Mounting ECZ Plug-in Base
Weight 0.25 kg

Technical FAQs

Does the ICSK 20 F1 require a specific mounting base?

Yes. The unit is designed to operate on an ECZ plug-in base. This configuration separates the electronics from field wiring and allows quick module replacement during maintenance.

How should I interpret the red Error LED on the front panel?

When the red indicator is active, refer to the error code list printed on the front panel. These codes help identify communication faults, power supply problems, or internal hardware issues.

Are the inputs on this model electrically isolated?

For the FPR3327101R1202 version, the power supply and inputs are non-isolated. Applications requiring electrical isolation should confirm grounding and system protection requirements before installation.

Engineering & Installation Guide

Bus Address Configuration:
Set the CS31 bus address using the DIP switches before inserting the module into the ECZ base. Each remote unit must have a unique address to prevent communication conflicts.

Relay Contact Protection:
Install surge suppression devices when controlling inductive loads. Use RC snubbers for AC loads and flyback diodes for DC loads to extend relay service life.

Wiring Integrity:
Ensure all terminal connections are tightened to the specified torque. Loose wiring can generate intermittent error signals or communication instability on the fieldbus network.

Testing Protocol:
Use the TEST push-button during commissioning to verify internal logic and indicator functionality before switching the system into RUN mode.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 1 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White Black
Country of origin
Sweden
Power source
DC Power

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping