| 1MRK005907-AA |
Distance protection zone, quadrilateral characteristic |
ZMQPDIS, ZMQAPDIS |
Impedance (Alt 1) |
| 1MRK005907-BA |
Directional impedance quadrilateral |
ZDRDIR |
Impedance (Alt 1 & 4) |
| 1MRK005907-CA |
Phase selection, quadrilateral characteristic with fixed angle |
FDPSPDIS |
Impedance (Alt 1, 2 & Opt 3) |
| 1MRK005907-DA |
Distance measuring zone, quadrilateral characteristic for series compensated lines |
ZMCPDIS, ZMCAPDIS |
Impedance (Alt 2) |
| 1MRK005907-EA |
Directional impedance quadrilateral, including series compensation |
ZDSRDIR |
Impedance (Alt 2) |
| 1MRK005907-FA |
Fullscheme distance protection, mho characteristic |
ZMHPDIS |
Impedance (Alt 3) |
| 1MRK005907-GA |
Fullscheme distance protection, quadrilateral for earth faults |
ZMMPDIS, ZMMAPDIS |
Impedance (Alt 3) |
| 1MRK005907-HA |
Directional impedance element for mho characteristic |
ZDMRDIR |
Impedance (Alt 3 & Opt 1) |
| 1MRK005907-KA |
Additional distance protection directional function for earth faults |
ZDARDIR |
Impedance (Alt 3 & Opt 1,2,4) |
| 1MRK005907-LA |
Mho Impedance supervision logic |
ZSMGAPC |
Impedance (Alt 3) |
| 1MRK005907-MA |
Faulty phase identification with load encroachment |
FMPSPDIS |
Impedance (Alt 3 & Opt 1,2,4) |
| 1MRK005907-NA |
Distance protection zone, quadrilateral characteristic, separate settings |
ZMRPDIS, ZMRAPDIS |
Impedance (Alt 4) |
| 1MRK005907-PA |
Phase selection, quadrilateral characteristic with settable angle |
FRPSPDIS |
Impedance (Alt 4) |
| 1MRK005907-SB |
High speed distance protection, quad and mho characteristic |
ZMFPDIS |
Impedance (Alt 5) |
| 1MRK005907-RB |
High speed distance protection for series compensated lines, quad and mho |
ZMFCPDIS |
Impedance (Alt 6) |
| 1MRK005907-UA |
Power swing detection |
ZMRPSB |
Impedance (Optional) |
| 1MRK005908-AA |
Automatic switch onto fault logic, voltage and current based |
ZCVPSOF |
Impedance (Optional) |
| 1MRK005907-VA |
Power swing logic |
PSLPSCH |
Impedance (Optional) |
| 1MRK005908-CB |
PoleSlip/Out-of-step protection |
PSPPPAM |
Impedance (Optional) |
| 1MRK005908-GA |
Out-of-step protection |
OOSPPAM |
Impedance (Optional) |
| 1MRK005908-DA |
Phase preference logic |
PPLPHIZ |
Impedance (Optional) |
| 1MRK005920-AA |
Scheme communication logic for distance or Overcurrent protection |
ZCPSCH |
Scheme Communication |
| 1MRK005920-BA |
Phase segregated Scheme communication logic for distance protection |
ZC1PPSCH |
Scheme Communication |
| 1MRK005920-CA |
Current reversal and weak-end infeed logic for distance protection |
ZCRWPSCH |
Scheme Communication |
| 1MRK005920-DA |
Current reversal and weak-end infeed logic for phase segregated communication |
ZC1WPSCH |
Scheme Communication |
| 1MRK005920-EA |
Local acceleration logic |
ZCLCPSCH |
Scheme Communication |
| 1MRK005920-FA |
Scheme communication logic for residual overcurrent protection |
ECPSCH |
Scheme Communication |
| 1MRK005920-GA |
Current reversal and weakend infeed logic for residual overcurrent protection |
ECRWPSCH |
Scheme Communication |
| 1MRK005921-AX |
Direct transfer trip |
DTT |
Scheme Communication |
| 1MRK005922-MX |
Configurable logic blocks Q/T |
- |
Logic Functions |
| 1MRK005922-AY |
Extension logic package |
- |
Logic Functions |
| 1MRK005924-HA |
Circuit breaker condition monitoring |
SSCBR |
Monitoring |
| 1MRK005925-XB |
Fault locator |
LMBRFLO |
Monitoring |
| 1MRK005930-TA |
Process Bus communication IEC 61850-9-2 |
- |
Station Communication |
| 1MRK002924-YB |
IEC 62439-3 parallel redundancy protocol |
PRP |
Station Communication |