Product Overview

The AKV 20-4 (042H2028) is a high-performance, electronically operated expansion valve designed for precise refrigerant injection in commercial and industrial refrigeration systems. Operating on a Pulse Width Modulation (PWM) principle, the Danfoss 042H2028 (042H2028) serves a dual purpose: it acts as both an expansion device and a liquid line solenoid valve. This integration is vital for B2B applications such as large-scale supermarket refrigeration, cold storage, and process cooling, where tight superheat (SH) control is required to maximize evaporator efficiency and protect the compressor from liquid slugging. The "Type 4" designation identifies this as a high-capacity unit within the AKV 20 series.

Technical Configuration

The AKV 20-4 utilizes a specialized 13.5 mm actuator system, engineered to interface seamlessly with Danfoss ADAP-KOOL controllers. Unlike traditional modulating valves that change needle depth, the 042H2028 cycles fully open and fully closed at specific intervals; the flow rate is precisely managed by the duration of the "open" time. This design results in a robust, hermetic valve with fewer moving parts, capable of millions of cycles. Rated for a Maximum Working Pressure (PS) of 28 bar (406 psig), it is compatible with a broad range of fluorinated refrigerants (HFC/HCFC), ensuring versatility across modern cooling infrastructures.

Technical Specifications

Feature Specification
Model AKV 20-4 (042H2028)
Brand Danfoss
Product Type Electric Expansion Valve (PWM)
Actuator System 13.5 mm
Max Working Pressure (PS) 28 bar (406 psig)
Max Test Pressure 42 bar
Ambient Temp Range -40 to 50 Celsius (-40 to 122 Fahrenheit)
Function NC (Normally Closed)
Refrigerant Compatibility R404A, R134a, R407C, R507, etc.
Weight 1.1 kg
Shipping Weight 1.5 kg

Technical FAQs

How does PWM control improve energy efficiency?

By using Pulse Width Modulation, the AKV 20-4 maintains a constant, high refrigerant velocity whenever it is open. This optimizes the heat transfer coefficient within the evaporator and ensures better oil return to the compressor compared to traditional mechanical valves that may throttle flow too low during low-load periods.

Does this valve provide a complete shut-off during power failure?

Yes. The 042H2028 is a Normally Closed (NC) valve. In the event of a power loss or when the controller reaches the setpoint, the valve closes hermetically, acting as a solenoid valve to prevent refrigerant migration.

Can this valve be used with CO2 (R744)?

The standard AKV 20 series is primarily designed for HFC/HCFC. For high-pressure CO2 applications, it is recommended to check the specific pressure ratings or look into the AKVH series, as R744 systems often exceed the 28 bar PS rating of this model.


Engineering & Installation Guide

  • Filtration Best Practices: To ensure the longevity of the 13.5 mm actuator and the internal seat, a high-quality filter drier (such as Danfoss DML) must be installed upstream. Because the valve cycles rapidly, any solid debris in the liquid line can cause abrasive wear or prevent the valve from closing fully.

  • Brazing & Thermal Safety: During the soldering of the inlet and outlet connections, it is mandatory to wrap the valve body in a wet cloth. The internal temperature must be kept below 100 Celsius to prevent damage to the precision-engineered seals and the actuator housing.

  • Electrical Installation: The solenoid coil (sold separately) must match the controller's voltage (AC or DC). Ensure the coil is mounted with the cable entry facing downward to create a "drip loop," preventing condensation from traveling into the electrical actuator interface.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States
Power source
AC-powered

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...