Allen-Bradley

Allen-Bradley 1746-P4 SLC 500 Power Supply

SKU 1746-P4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley
  • Product No.: 1746-P4
  • Origin United States
  • Product Type: PLC Power Supply
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Allen-Bradley 1746-P4 is a reliable and robust modular power supply designed specifically for the Allen-Bradley SLC 500 fixed and modular controller systems. This unit provides regulated 5VDC and 24VDC power directly to the backplane of the local chassis, supporting CPU operation, communication modules, and digital or analog I/O expansion modules. Built for industrial automation environments, it ensures reliable distribution of backplane power while maintaining system integrity during routine line fluctuations.

Featuring a selectable line voltage input range, the 1746-P4 adapts easily to common industrial power distribution standards. It includes built-in hold-up time capabilities to keep the processor scanning safely during brief voltage sags or brownouts, and initiates controlled shutdowns when input power is lost for extended periods. The soldered internal fuse and high-isolation design protect sensitive downstream electronics against electrical noise and ground disturbances commonly found in factory floor settings.

Features

    Selectable input voltage range supporting 85 to 132 VAC or 170 to 265 VAC at 47 to 63 Hz
    Delivers up to 10.0 A of internal current capacity at 5 VDC for backplane power
    Delivers up to 2.88 A of internal current capacity at 24 VDC
    Provides 1 A at 24 VDC user power current capacity for compatible field devices
    Built-in CPU hold-up time of 20 ms at full load and up to 3,000 ms at no load
    Standard 32 to 140 Fahrenheit (0 to 60 Celsius) operating temperature range with no derating required
    Robust 2,600 VDC isolation tested for 1 second to ensure operator and equipment safety

Applications

    Allen-Bradley SLC 500 modular rack power distribution
    Discrete and analog I/O chassis backplane power supply
    Factory automation and discrete manufacturing lines
    Material handling and conveyor control systems
    Water and wastewater treatment processing equipment

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number / Model 1746-P4
Product Type SLC 500 Power Supply
Line Voltage Range 85 to 132 VAC / 170 to 265 VAC (User Selectable)
Line Frequency 47 to 63 Hz
Backplane Current Capacity (5 VDC) 10.0 A
Backplane Current Capacity (24 VDC) 2.88 A
User Power Voltage Range 20.4 to 27.6 VDC
User Power Current Capacity 1.0 A @ 24 VDC
CPU Hold-Up Time 20 ms (Full Load) to 3,000 ms (No Load)
Isolation Voltage 2,600 VDC for 1 s
Operating Temperature 0 to 60 Celsius (32 to 140 Fahrenheit)
Country of Origin United States

Installation Guidelines

Ensure all incoming line voltage is completely disconnected and locked out before installing or removing the 1746-P4 power supply. Mount the power supply securely into the extreme left-hand slot of the SLC 500 modular chassis as mandated by rack architecture guidelines. Connect the protective earth ground terminal directly to the enclosure ground bus bar using low-impedance wire to reduce electromagnetic interference. Verify that the selectable voltage switch on the side of the unit matches your facility's incoming line voltage before applying power.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Allen-Bradley 1746-P4 and what systems does it support?
The Allen-Bradley 1746-P4 is a robust modular power supply designed specifically for Allen-Bradley SLC 500 fixed and modular controller systems. It mounts securely into the extreme left-hand slot of the chassis to deliver regulated power directly to the backplane. This unit effectively supports CPU operation, communication modules, and various digital or analog I/O expansion modules.
What are the input voltage and current output specifications for the Allen-Bradley 1746-P4?
The Allen-Bradley 1746-P4 features a user-selectable input voltage range supporting 85 to 132 VAC or 170 to 265 VAC at 47 to 63 Hz. It delivers up to 10.0 A of internal current capacity at 5 VDC and 2.88 A at 24 VDC for the backplane. Additionally, the unit provides 1 A of user power current capacity at 24 VDC for compatible field devices.
How does the Allen-Bradley 1746-P4 handle power sags and electrical isolation?
The Allen-Bradley 1746-P4 includes a built-in CPU hold-up time of 20 ms at full load, which keeps the processor scanning safely during brief voltage sags or brownouts. It is built with a high-isolation design tested to 2,600 VDC for 1 second to protect sensitive downstream electronics. This robust electrical isolation helps mitigate ground disturbances and electrical noise typically found in factory floor settings.
What are the operating temperature limits and environmental ratings of the Allen-Bradley 1746-P4?
The Allen-Bradley 1746-P4 operates reliably within a standard industrial temperature range of 32 to 140 Fahrenheit (0 to 60 Celsius). It maintains this full operating window with no derating required in typical industrial automation environments. This rugged thermal performance makes it suitable for demanding applications like discrete manufacturing, material handling, and water treatment processing.
What installation precautions should be taken when setting up the Allen-Bradley 1746-P4?
When installing the Allen-Bradley 1746-P4, you must ensure that all incoming line voltage is completely disconnected and locked out to prevent electrical hazards. You need to verify that the selectable voltage switch on the side of the unit matches your facility's incoming line voltage prior to startup. Finally, connect the protective earth ground terminal directly to the enclosure ground bus bar using low-impedance wire to minimize electromagnetic interference.
Reviews

1746-P4

Stock & lead time on request

Call
1 of 1

Allen-Bradley 1746-P4 SLC 500 Power Supply

Only 16 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1746-P4

  • Country of origin:United States

  • Product Type: PLC Power Supply

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Allen-Bradley 1746-P4 is a reliable and robust modular power supply designed specifically for the Allen-Bradley SLC 500 fixed and modular controller systems. This unit provides regulated 5VDC and 24VDC power directly to the backplane of the local chassis, supporting CPU operation, communication modules, and digital or analog I/O expansion modules. Built for industrial automation environments, it ensures reliable distribution of backplane power while maintaining system integrity during routine line fluctuations.

Featuring a selectable line voltage input range, the 1746-P4 adapts easily to common industrial power distribution standards. It includes built-in hold-up time capabilities to keep the processor scanning safely during brief voltage sags or brownouts, and initiates controlled shutdowns when input power is lost for extended periods. The soldered internal fuse and high-isolation design protect sensitive downstream electronics against electrical noise and ground disturbances commonly found in factory floor settings.

Features

    Selectable input voltage range supporting 85 to 132 VAC or 170 to 265 VAC at 47 to 63 Hz
    Delivers up to 10.0 A of internal current capacity at 5 VDC for backplane power
    Delivers up to 2.88 A of internal current capacity at 24 VDC
    Provides 1 A at 24 VDC user power current capacity for compatible field devices
    Built-in CPU hold-up time of 20 ms at full load and up to 3,000 ms at no load
    Standard 32 to 140 Fahrenheit (0 to 60 Celsius) operating temperature range with no derating required
    Robust 2,600 VDC isolation tested for 1 second to ensure operator and equipment safety

Applications

    Allen-Bradley SLC 500 modular rack power distribution
    Discrete and analog I/O chassis backplane power supply
    Factory automation and discrete manufacturing lines
    Material handling and conveyor control systems
    Water and wastewater treatment processing equipment

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number / Model 1746-P4
Product Type SLC 500 Power Supply
Line Voltage Range 85 to 132 VAC / 170 to 265 VAC (User Selectable)
Line Frequency 47 to 63 Hz
Backplane Current Capacity (5 VDC) 10.0 A
Backplane Current Capacity (24 VDC) 2.88 A
User Power Voltage Range 20.4 to 27.6 VDC
User Power Current Capacity 1.0 A @ 24 VDC
CPU Hold-Up Time 20 ms (Full Load) to 3,000 ms (No Load)
Isolation Voltage 2,600 VDC for 1 s
Operating Temperature 0 to 60 Celsius (32 to 140 Fahrenheit)
Country of Origin United States

Installation Guidelines

Ensure all incoming line voltage is completely disconnected and locked out before installing or removing the 1746-P4 power supply. Mount the power supply securely into the extreme left-hand slot of the SLC 500 modular chassis as mandated by rack architecture guidelines. Connect the protective earth ground terminal directly to the enclosure ground bus bar using low-impedance wire to reduce electromagnetic interference. Verify that the selectable voltage switch on the side of the unit matches your facility's incoming line voltage before applying power.

Loading product navigation…

What is the Allen-Bradley 1746-P4 and what systems does it support?

The Allen-Bradley 1746-P4 is a robust modular power supply designed specifically for Allen-Bradley SLC 500 fixed and modular controller systems. It mounts securely into the extreme left-hand slot of the chassis to deliver regulated power directly to the backplane. This unit effectively supports CPU operation, communication modules, and various digital or analog I/O expansion modules.

What are the input voltage and current output specifications for the Allen-Bradley 1746-P4?

The Allen-Bradley 1746-P4 features a user-selectable input voltage range supporting 85 to 132 VAC or 170 to 265 VAC at 47 to 63 Hz. It delivers up to 10.0 A of internal current capacity at 5 VDC and 2.88 A at 24 VDC for the backplane. Additionally, the unit provides 1 A of user power current capacity at 24 VDC for compatible field devices.

How does the Allen-Bradley 1746-P4 handle power sags and electrical isolation?

The Allen-Bradley 1746-P4 includes a built-in CPU hold-up time of 20 ms at full load, which keeps the processor scanning safely during brief voltage sags or brownouts. It is built with a high-isolation design tested to 2,600 VDC for 1 second to protect sensitive downstream electronics. This robust electrical isolation helps mitigate ground disturbances and electrical noise typically found in factory floor settings.

What are the operating temperature limits and environmental ratings of the Allen-Bradley 1746-P4?

The Allen-Bradley 1746-P4 operates reliably within a standard industrial temperature range of 32 to 140 Fahrenheit (0 to 60 Celsius). It maintains this full operating window with no derating required in typical industrial automation environments. This rugged thermal performance makes it suitable for demanding applications like discrete manufacturing, material handling, and water treatment processing.

What installation precautions should be taken when setting up the Allen-Bradley 1746-P4?

When installing the Allen-Bradley 1746-P4, you must ensure that all incoming line voltage is completely disconnected and locked out to prevent electrical hazards. You need to verify that the selectable voltage switch on the side of the unit matches your facility's incoming line voltage prior to startup. Finally, connect the protective earth ground terminal directly to the enclosure ground bus bar using low-impedance wire to minimize electromagnetic interference.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.