Allen-Bradley

Allen-Bradley 1769-IF8 Compact I/O Analog Input Module

SKU 1769-IF8

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley
  • Product No.: 1769-IF8
  • Origin Malaysia
  • Product Type: Analog Input Module
  • Payment: T/T, Western Union
  • Weight: 0.28 kg
  • Dimensions: 118 x 35 x 87 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1769-IF8 Compact I/O Analog Input Module

Quantity

Product Description

Description

The Allen-Bradley 1769-IF8 is an 8-channel analog current/voltage input module designed for process signal acquisition in industrial automation architectures. Operating within the CompactLogix platform, it converts analog field signals from sensors, transmitters, and transducers into digital values for control execution.

The module supports individual channel configuration across voltage ranges of +/-10V, 0…10V, and 0…5V, as well as current ranges including 0…20mA and 4…20mA. Built with an integrated communication bus and removable terminal block, it provides field-wire connection points while offering 500V AC or 710V DC optical isolation to shield control logic from field electrical transients.

As part of the Compact I/O family, the 1769-IF8 can be mounted directly on a DIN rail or panel. It integrates into local CompactLogix controller assemblies, expansion racks using standard power supplies, or distributed I/O stations linked through DeviceNet (1769-ADN) or EtherNet/IP (1769-AENTR) network adapters.

Features

  • Features 8 analog input channels supporting unipolar and bipolar voltage or current signal ranges.
  • Includes optical isolation rated at 500V AC or 710V DC for 1 minute between field circuits and system logic.
  • Equipped with a removable terminal block (RTB) behind a protective door for easier field wiring and module swapping.
  • Built with a patented movable bus connector and tongue-and-groove alignment slots for solid backplane communication.
  • Designed for flexible mounting options on standard DIN rail or direct panel installations.
  • Utilizes self-lifting field-wire pressure plates to streamline installation and maintenance workflows.

Applications

  • Scalable process signal monitoring in CompactLogix control architectures.
  • Analog data acquisition for pressure, temperature, flow, and level transmitters.
  • Distributed I/O expansion via EtherNet/IP (1769-AENTR) or DeviceNet (1769-ADN) communication adapters.
  • Local expansion I/O for MicroLogix 1500 controller assemblies.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1769-IF8
Product Type Analog Current/Voltage Input Module
Number of Inputs 8 channels
Input Signal Ranges +/-10V, 0…10V, 0…5V, 1…5V, 0…20mA, 4…20mA
Current Draw @ 5.1V DC 120 mA
Current Draw @ 24V DC 70 mA
Isolation Voltage 500V AC or 710V DC for 1 min (qualifying test), 30V AC / 30V DC working voltage
Operating Temperature 0...60 degC (32...140 degF)
Nonoperating Temperature -40...+85 degC (-40...+185 degF)
Relative Humidity 5...95% noncondensing
Operating Vibration 5 g @ 10...500 Hz
Operating Shock 30 g (Panel Mount), 20 g (DIN Rail Mount)
Nonoperating Shock 40 g (Panel Mount), 30 g (DIN Rail Mount)
Power Supply Distance Rating 8 modules
Dimensions (H x W x D) 118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.)
Dimensions with Mounting Tabs Height 138 mm (5.43 in.)
Slot Width 1
Module Location DIN Rail or Panel Mount
Country of Origin Malaysia

Installation Guidelines

  1. Confirm the catalog number (1769-IF8) and verify that power supply and bus specifications match system requirements before installation.
  2. Ensure system power is completely disconnected before inserting or removing modules from the Compact I/O assembly.
  3. Align the module tongue-and-groove slots with adjacent modules or the controller and slide into place until fully seated.
  4. Secure the module to the DIN rail using the DIN rail latch, or mount directly to a panel using two mounting screws.
  5. Move the bus connector slide switch to lock the backplane communication bus across adjacent modules.
  6. Wire analog transmitters and sensors to the removable terminal block according to voltage or current input configurations, observing correct signal polarity and shielding practices.

Configuration and Replacement Recommendations

  • Parameter Backup: Upload and save the existing controller project, module configuration data, and scaling parameters prior to removing an active module.
  • Module Replacement: When replacing an existing module, ensure backplane power is off, loosen the terminal block retaining screws, pull the removable terminal block away, swap the module, and reconnect the terminal block.
  • Shielding: Use twisted-pair shielded cable for analog input signals and ground the shield at one end only to prevent ground loops and noise interference.
  • Distance Rating: Verify that the module is installed within its 8-module power supply distance rating relative to the system 1769 power supply.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What input signal types does the Allen-Bradley 1769-IF8 analog module support?
The module supports both voltage and current analog field signals. Configurable range options include +/-10V, 0…10V, 0…5V, 1…5V, as well as 0…20mA and 4…20mA current loops.
What is the power supply distance rating for the 1769-IF8 module?
The module has a power supply distance rating of 8 modules. It must be installed within 8 module slots of a 1769 Compact I/O power supply.
Can the 1769-IF8 module be used in distributed I/O architectures?
Yes, the module can be installed in distributed expansion banks connected via network adapters such as the 1769-AENTR for EtherNet/IP or the 1769-ADN for DeviceNet.
How is the 1769-IF8 module mounted in a control cabinet?
The device can be installed directly on a standard 35 mm DIN rail or panel-mounted using two screws. It mechanically locks to adjacent Compact I/O modules using built-in tongue-and-groove guide slots.
Reviews

1769-IF8

Stock & lead time on request

Call
1 of 1

Allen-Bradley 1769-IF8 Compact I/O Analog Input Module

Only 17 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1769-IF8

  • Country of origin:Malaysia

  • Product Type: Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 280g

  • Dimensions: 118 x 35 x 87 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Allen-Bradley 1769-IF8 is an 8-channel analog current/voltage input module designed for process signal acquisition in industrial automation architectures. Operating within the CompactLogix platform, it converts analog field signals from sensors, transmitters, and transducers into digital values for control execution.

The module supports individual channel configuration across voltage ranges of +/-10V, 0…10V, and 0…5V, as well as current ranges including 0…20mA and 4…20mA. Built with an integrated communication bus and removable terminal block, it provides field-wire connection points while offering 500V AC or 710V DC optical isolation to shield control logic from field electrical transients.

As part of the Compact I/O family, the 1769-IF8 can be mounted directly on a DIN rail or panel. It integrates into local CompactLogix controller assemblies, expansion racks using standard power supplies, or distributed I/O stations linked through DeviceNet (1769-ADN) or EtherNet/IP (1769-AENTR) network adapters.

Features

  • Features 8 analog input channels supporting unipolar and bipolar voltage or current signal ranges.
  • Includes optical isolation rated at 500V AC or 710V DC for 1 minute between field circuits and system logic.
  • Equipped with a removable terminal block (RTB) behind a protective door for easier field wiring and module swapping.
  • Built with a patented movable bus connector and tongue-and-groove alignment slots for solid backplane communication.
  • Designed for flexible mounting options on standard DIN rail or direct panel installations.
  • Utilizes self-lifting field-wire pressure plates to streamline installation and maintenance workflows.

Applications

  • Scalable process signal monitoring in CompactLogix control architectures.
  • Analog data acquisition for pressure, temperature, flow, and level transmitters.
  • Distributed I/O expansion via EtherNet/IP (1769-AENTR) or DeviceNet (1769-ADN) communication adapters.
  • Local expansion I/O for MicroLogix 1500 controller assemblies.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Catalog Number 1769-IF8
Product Type Analog Current/Voltage Input Module
Number of Inputs 8 channels
Input Signal Ranges +/-10V, 0…10V, 0…5V, 1…5V, 0…20mA, 4…20mA
Current Draw @ 5.1V DC 120 mA
Current Draw @ 24V DC 70 mA
Isolation Voltage 500V AC or 710V DC for 1 min (qualifying test), 30V AC / 30V DC working voltage
Operating Temperature 0...60 degC (32...140 degF)
Nonoperating Temperature -40...+85 degC (-40...+185 degF)
Relative Humidity 5...95% noncondensing
Operating Vibration 5 g @ 10...500 Hz
Operating Shock 30 g (Panel Mount), 20 g (DIN Rail Mount)
Nonoperating Shock 40 g (Panel Mount), 30 g (DIN Rail Mount)
Power Supply Distance Rating 8 modules
Dimensions (H x W x D) 118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.)
Dimensions with Mounting Tabs Height 138 mm (5.43 in.)
Slot Width 1
Module Location DIN Rail or Panel Mount
Country of Origin Malaysia

Installation Guidelines

  1. Confirm the catalog number (1769-IF8) and verify that power supply and bus specifications match system requirements before installation.
  2. Ensure system power is completely disconnected before inserting or removing modules from the Compact I/O assembly.
  3. Align the module tongue-and-groove slots with adjacent modules or the controller and slide into place until fully seated.
  4. Secure the module to the DIN rail using the DIN rail latch, or mount directly to a panel using two mounting screws.
  5. Move the bus connector slide switch to lock the backplane communication bus across adjacent modules.
  6. Wire analog transmitters and sensors to the removable terminal block according to voltage or current input configurations, observing correct signal polarity and shielding practices.

Configuration and Replacement Recommendations

  • Parameter Backup: Upload and save the existing controller project, module configuration data, and scaling parameters prior to removing an active module.
  • Module Replacement: When replacing an existing module, ensure backplane power is off, loosen the terminal block retaining screws, pull the removable terminal block away, swap the module, and reconnect the terminal block.
  • Shielding: Use twisted-pair shielded cable for analog input signals and ground the shield at one end only to prevent ground loops and noise interference.
  • Distance Rating: Verify that the module is installed within its 8-module power supply distance rating relative to the system 1769 power supply.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1769-IF8 Compact I/O Analog Input Module

What input signal types does the Allen-Bradley 1769-IF8 analog module support?

The module supports both voltage and current analog field signals. Configurable range options include +/-10V, 0…10V, 0…5V, 1…5V, as well as 0…20mA and 4…20mA current loops.

What is the power supply distance rating for the 1769-IF8 module?

The module has a power supply distance rating of 8 modules. It must be installed within 8 module slots of a 1769 Compact I/O power supply.

Can the 1769-IF8 module be used in distributed I/O architectures?

Yes, the module can be installed in distributed expansion banks connected via network adapters such as the 1769-AENTR for EtherNet/IP or the 1769-ADN for DeviceNet.

How is the 1769-IF8 module mounted in a control cabinet?

The device can be installed directly on a standard 35 mm DIN rail or panel-mounted using two screws. It mechanically locks to adjacent Compact I/O modules using built-in tongue-and-groove guide slots.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Malaysia

Technical knowledge

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...

Connecting GX Simulator to Factory I/O Through OPC

A stable Mitsubishi virtual commissioning setup requires more than matching addresses. This guide explains the GX Simulator–OPC–Factory I/O data path, namespace design, scan timing, validation, and...