The BECKHOFF BC5250 is a compact Bus Terminal Controller that integrates DeviceNet fieldbus systems with the modular Beckhoff Bus Terminal I/O system. Operating as a decentralized controller with localized intelligence, it features an integrated PLC runtime system that executes independent control programs. The device is configured and programmed using TwinCAT automation software in compliance with the IEC 61131-3 standard, allowing users to build distributed control architectures with localized processing capabilities.

This controller manages data exchange between the DeviceNet network and connected local Bus Terminals. The integrated local PLC can process input and output signals independently of the higher-level fieldbus master, ensuring continuous operation of local machine processes even in the event of fieldbus connection interruptions. Its space-saving design is optimized for mounting in control cabinets and terminal boxes where space is at a premium.

Features

  • Integrated IEC 61131-3 PLC runtime system configurable via TwinCAT.
  • Supports up to 64 local Bus Terminals (expandable to 255 with K-bus extension).
  • Automatic baud rate detection up to 500 kbaud on the DeviceNet interface.
  • Equipped with local serial programming and configuration interface.
  • Diagnostic LEDs indicating network status, PLC status, and local bus activity.
  • Compact DIN-rail mount housing designed for space-restricted environments.

Applications

  • Decentralized industrial automation nodes requiring local PLC logic.
  • Machine building and manufacturing assemblies operating on DeviceNet fieldbus systems.
  • Localized data pre-processing and conditioning before fieldbus transmission.
  • Independent subsystem control where high availability is required.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model BC5250
Product Type DeviceNet Compact Bus Terminal Controller

Controller Performance and Memory

Programming Software TwinCAT (via serial programming interface or fieldbus)
Programming Languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Program Memory 48 kbytes
Data Memory 32 kbytes
Remanent Data 2 bytes
Runtime System 1 PLC task
PLC Cycle Time Approx. 3 ms for 1,000 instructions (excluding local I/O cycle)
Online Change Support Yes

Fieldbus and I/O Capacity

Fieldbus Interface DeviceNet
Bus Connection 5-pin open style connector
Baud Rates Automatic detection up to 500 kbaud
Number of Bus Terminals 64 (up to 255 via K-bus extension)
Max. Process Image Size 512 bytes input / 512 bytes output
Max. Digital Peripheral Signals 512 inputs / 512 outputs
Max. Analog Peripheral Signals 128 inputs / 128 outputs

Electrical Data

Supply Voltage 24 V DC (-15% / +20%)
Max. Input Current 320 mA
K-bus Current Supply 1750 mA
Power Contacts Current Load Max. 10 A
Electrical Isolation 500 V (power contacts / supply voltage)

Mechanical and Environmental

Dimensions (W x H x D) 44 mm x 100 mm x 68 mm
Weight Approx. 100 g
Mounting 35 mm DIN rail (conforming to EN 60715) with double slot and key lock
Housing Material Polycarbonate
Conductor Connection Cross-section (Solid/Stranded) 0.08 to 2.5 mm²
Conductor Connection Cross-section (with Ferrule) 0.14 to 1.5 mm²
Stripping Length 8 to 9 mm
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20

Installation Guidelines

  1. Ensure all electrical power sources are completely de-energized before mounting or wiring the system.
  2. Securely mount the controller onto a standard 35 mm DIN rail (conforming to EN 60715) using the integrated double slot and key locking mechanism.
  3. Slide connected Bus Terminals laterally to join the controller's K-bus interface. Ensure they are locked firmly in place side-by-side.
  4. Connect the 24 V DC supply power to the controller terminals and ground reference according to schematic diagrams.
  5. Wire the 5-pin open style DeviceNet connector, ensuring proper shield grounding rules are maintained.
  6. Insert wiring into terminals using a standard screwdriver to actuate the internal spring mechanism. Strip insulation to the specified 8 to 9 mm length.
  7. Configure and load local control programs utilizing TwinCAT through the serial programming port or via the fieldbus master.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the main function of the BECKHOFF BC5250?
The BECKHOFF BC5250 is a compact Bus Terminal Controller that provides local PLC functionality and connects up to 64 local Beckhoff Bus Terminals directly to a DeviceNet fieldbus system.
How is the BECKHOFF BC5250 programmed?
The BECKHOFF BC5250 is programmed using the TwinCAT software system in accordance with IEC 61131-3 standards, using either the onboard serial configuration interface or the fieldbus itself.
How many local Bus Terminals can be connected to the BECKHOFF BC5250?
A maximum of 64 standard Bus Terminals can be connected directly to the BECKHOFF BC5250, with the option to expand up to 255 terminals using a K-bus extension system.
What are the onboard memory capacities of the BECKHOFF BC5250?
The BECKHOFF BC5250 is equipped with 48 kbytes of program memory, 32 kbytes of data memory, and 2 bytes of remanent data memory to execute local control logic.
Does the BECKHOFF BC5250 support auto-detection of network transmission rates?
Yes, the BECKHOFF BC5250 automatically detects transmission speeds on the DeviceNet network up to a maximum of 500 kbaud.
Reviews

BC5250

Stock & lead time on request

Call
1 of 1

BECKHOFF BC5250 DeviceNet Compact Bus Terminal Controller

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: BC5250

  • Country of origin:Germany

  • Product Type: Bus Terminal Controllers

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 44 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF BC5250 is a compact Bus Terminal Controller that integrates DeviceNet fieldbus systems with the modular Beckhoff Bus Terminal I/O system. Operating as a decentralized controller with localized intelligence, it features an integrated PLC runtime system that executes independent control programs. The device is configured and programmed using TwinCAT automation software in compliance with the IEC 61131-3 standard, allowing users to build distributed control architectures with localized processing capabilities.

This controller manages data exchange between the DeviceNet network and connected local Bus Terminals. The integrated local PLC can process input and output signals independently of the higher-level fieldbus master, ensuring continuous operation of local machine processes even in the event of fieldbus connection interruptions. Its space-saving design is optimized for mounting in control cabinets and terminal boxes where space is at a premium.

Features

  • Integrated IEC 61131-3 PLC runtime system configurable via TwinCAT.
  • Supports up to 64 local Bus Terminals (expandable to 255 with K-bus extension).
  • Automatic baud rate detection up to 500 kbaud on the DeviceNet interface.
  • Equipped with local serial programming and configuration interface.
  • Diagnostic LEDs indicating network status, PLC status, and local bus activity.
  • Compact DIN-rail mount housing designed for space-restricted environments.

Applications

  • Decentralized industrial automation nodes requiring local PLC logic.
  • Machine building and manufacturing assemblies operating on DeviceNet fieldbus systems.
  • Localized data pre-processing and conditioning before fieldbus transmission.
  • Independent subsystem control where high availability is required.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model BC5250
Product Type DeviceNet Compact Bus Terminal Controller

Controller Performance and Memory

Programming Software TwinCAT (via serial programming interface or fieldbus)
Programming Languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Program Memory 48 kbytes
Data Memory 32 kbytes
Remanent Data 2 bytes
Runtime System 1 PLC task
PLC Cycle Time Approx. 3 ms for 1,000 instructions (excluding local I/O cycle)
Online Change Support Yes

Fieldbus and I/O Capacity

Fieldbus Interface DeviceNet
Bus Connection 5-pin open style connector
Baud Rates Automatic detection up to 500 kbaud
Number of Bus Terminals 64 (up to 255 via K-bus extension)
Max. Process Image Size 512 bytes input / 512 bytes output
Max. Digital Peripheral Signals 512 inputs / 512 outputs
Max. Analog Peripheral Signals 128 inputs / 128 outputs

Electrical Data

Supply Voltage 24 V DC (-15% / +20%)
Max. Input Current 320 mA
K-bus Current Supply 1750 mA
Power Contacts Current Load Max. 10 A
Electrical Isolation 500 V (power contacts / supply voltage)

Mechanical and Environmental

Dimensions (W x H x D) 44 mm x 100 mm x 68 mm
Weight Approx. 100 g
Mounting 35 mm DIN rail (conforming to EN 60715) with double slot and key lock
Housing Material Polycarbonate
Conductor Connection Cross-section (Solid/Stranded) 0.08 to 2.5 mm²
Conductor Connection Cross-section (with Ferrule) 0.14 to 1.5 mm²
Stripping Length 8 to 9 mm
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20

Installation Guidelines

  1. Ensure all electrical power sources are completely de-energized before mounting or wiring the system.
  2. Securely mount the controller onto a standard 35 mm DIN rail (conforming to EN 60715) using the integrated double slot and key locking mechanism.
  3. Slide connected Bus Terminals laterally to join the controller's K-bus interface. Ensure they are locked firmly in place side-by-side.
  4. Connect the 24 V DC supply power to the controller terminals and ground reference according to schematic diagrams.
  5. Wire the 5-pin open style DeviceNet connector, ensuring proper shield grounding rules are maintained.
  6. Insert wiring into terminals using a standard screwdriver to actuate the internal spring mechanism. Strip insulation to the specified 8 to 9 mm length.
  7. Configure and load local control programs utilizing TwinCAT through the serial programming port or via the fieldbus master.
Loading product navigation…

What is the main function of the BECKHOFF BC5250?

The BECKHOFF BC5250 is a compact Bus Terminal Controller that provides local PLC functionality and connects up to 64 local Beckhoff Bus Terminals directly to a DeviceNet fieldbus system.

How is the BECKHOFF BC5250 programmed?

The BECKHOFF BC5250 is programmed using the TwinCAT software system in accordance with IEC 61131-3 standards, using either the onboard serial configuration interface or the fieldbus itself.

How many local Bus Terminals can be connected to the BECKHOFF BC5250?

A maximum of 64 standard Bus Terminals can be connected directly to the BECKHOFF BC5250, with the option to expand up to 255 terminals using a K-bus extension system.

What are the onboard memory capacities of the BECKHOFF BC5250?

The BECKHOFF BC5250 is equipped with 48 kbytes of program memory, 32 kbytes of data memory, and 2 bytes of remanent data memory to execute local control logic.

Does the BECKHOFF BC5250 support auto-detection of network transmission rates?

Yes, the BECKHOFF BC5250 automatically detects transmission speeds on the DeviceNet network up to a maximum of 500 kbaud.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...