Beckhoff BK5151 Bus Coupler CANopen Compact Module

Beckhoff BK5151 Bus Coupler CANopen Compact Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: BK5151

  • Country of origin:Germany

  • Product Type: CANopen Bus Couplers

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Integrating standard K-bus I/O terminals into high-speed CANopen fieldbus networks, the Beckhoff BK5151 offers a compact, cost-efficient interface solution. This unit acts as a gateway, mapping standard terminal signal channels to the CANopen communication layer and process image. The complete Beckhoff BK5151 system supports automatic baud rate configuration and diagnostic feedback, ensuring seamless integration into distributed control systems.

Features

  • Flexible Expansion: Connects up to 64 local Bus Terminals, with support for up to 255 terminals via K-bus extension units.
  • High-Speed Communication: Automatic baud rate detection supports transmission speeds reaching up to 1 Mbaud.
  • Robust K-Bus Power Supply: Generates up to 1750 mA of current output for internal electronics of connected terminals.
  • Rich CANopen Services: Fully supports emergency objects, variable mapping, Node Guarding, Life Guarding, and store/restore options.
  • Configurable Transfer Modes: Supports synchronous, cyclic, event-driven, and polling-based PDO modes.

Applications

  • Decentralized factory automation and plant control systems.
  • Hazardous environments requiring ATEX and IECEx Zone 2 intrinsic safety ratings.
  • Material handling and machine building environments using centralized CANopen masters.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / SKU BK5151
Fieldbus Protocol CANopen
Bus Interface Connection 9-pin D-sub socket
Baud Rate Up to 1 Mbaud (automatic detection)
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Internal K-Bus Current 1750 mA
Power Supply Voltage 24 V DC (-15% / +20%)
Diagnostic LEDs 2 x power supply, 2 x K-bus, 2 x fieldbus
Protection Rating IP20
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Hazardous Area Certifications ATEX: II 3G Ex ec IIC T4 Gc / IECEx: Ex ec IIC T4 Gc
Net Weight 100 g
Shipping Weight (Calculated) 1.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The BK5151 replaces older BK5120 couplers in typical architectures. However, configure your software environments carefully: any hardware modifications or firmware transitions from standard BK series to the compact "BK5151" require an updated EDS (Electronic Datasheet) file imported directly into your CANopen master configuration utility to correctly register the updated device ID and dynamic mapping options.

Application Pitfalls & Engineering Notes

When sizing your system, calculate the total current consumption of the connected K-bus terminals. Although the integrated power unit outputs 1750 mA, exceeding this threshold will trigger a K-bus undervoltage alarm, interrupting communication. If your I/O array draws higher currents, insert a PE2001 power feed terminal downstream on the rail to supply supplemental voltage.

Commissioning & Wiring Tips

Always ensure that both physical ends of the CANopen network bus segment are terminated with a standard 120-Ohm resistor connected between CAN-H (pin 7) and CAN-L (pin 2). Omission of physical termination is a primary cause of packet collisions, CRC errors, and intermittent bus-off states. Use only double-shielded twisted pair copper media for field connections.

Installation Guidelines

CRITICAL WARNING: Completely isolate and lock out all 24 V DC power supplies prior to mounting, connecting, or disconnecting the coupler. Live hot-plugging of the local K-bus terminals can cause physical hardware damage and electrical system instability.
1
Mount the BK5151 unit firmly onto a standard 35 mm DIN rail (EN 60715) with vertical orientation for optimal heat dissipation.
2
Assemble the subsequent K-bus terminals onto the right side of the coupler unit, ensuring all physical mechanical and electrical side-locking tabs align and snap together securely.
3
Connect the 9-pin D-sub CAN interface, apply termination resistors if the unit is located at the physical ends of the line, and plug in the 24 V DC auxiliary feed wiring.
Loading product navigation…

What is the maximum K-bus current capacity of the BK5151?

The BK5151 compact bus coupler supplies up to 1750 mA to power the internal electronics of the connected K-bus terminals.

How many K-bus terminals can be physically connected to this coupler?

You can connect up to 64 standard Bus Terminals directly. With K-bus extension terminals, the architecture can scale up to 255 terminals.

Does this module support automatic CANopen baud rate detection?

Yes, it automatically detects transmission speeds up to 1 Mbaud, ensuring compatibility with configured master nodes on the fieldbus segment.

What kind of fieldbus connector does the BK5151 use?

The module is designed with an integrated D-sub 9-pin socket for standard, rugged fieldbus connections.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...