BECKHOFF

Beckhoff CX2030-0130 CX Series Basic CPU Module

SKU CX2030-0130

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX2030-0130

  • Country of origin:Germany

  • Product Type: Embedded PC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 144 mm x 99 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for high-performance automation tasks requiring multi-core processing power, the Beckhoff CX2030-0130 serves as a robust Embedded PC basic CPU module within the CX modular controller series. Featuring an Intel Core i7 2610UE processor running at 1.5 GHz, this dual-core module delivers exceptional computational throughput for complex TwinCAT control algorithms, visualization tasks, and motion control applications. It interfaces directly with modular I/O systems using automatic recognition of E-bus or K-bus communication, making it highly versatile for demanding industrial environments.

Features

  • Dual-core Intel Core i7 processor operating at 1.5 GHz.
  • Integrated 2 GB DDR3 RAM, offering high-speed volatile data access.
  • Built-in 128 kB NOVRAM for secure, non-volatile retention of critical variables.
  • Dual independent RJ45 gigabit ports (10/100/1000 Mbit/s) for network segmentation.
  • Direct video output via an integrated DVI-I interface.
  • Four USB 2.0 ports and one option slot for modular expansion interfaces.
  • Automatic physical I/O recognition supporting both EtherCAT Terminals (E-bus) and Bus Terminals (K-bus).

Applications

  • High-speed manufacturing and packaging machinery control.
  • Multi-axis coordinated motion control and robotics.
  • Centralized building automation system controllers.
  • Process control systems requiring localized high-capacity data processing.
  • Industrial IoT gateways and edge computing applications.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number CX2030-0130
Processor Intel Core i7 2610UE 1.5 GHz (Dual Core)
Main Memory 2 GB DDR3 RAM
Persistent Memory 128 kB NOVRAM integrated
Flash Storage 20 GB or 40 GB CFast card slot (operating system dependent)
Interfaces 2 x RJ45 (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0, 1 x Option Slot
Diagnostics LED 1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status
Control Software Compatibility TwinCAT 2 Runtime, TwinCAT 3 Runtime (XAR)
TwinCAT 3 Platform Level Mid Performance Plus (60)
Input Supply Voltage 24 V DC (-15% / +20%)
Max. Power Consumption 27 W
I/O Connection Type Via power supply module (E-bus or K-bus auto-detection)
Protection Rating IP20
Operating Temperature -25 to +60 degC (no condensation)
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 144 mm x 99 mm x 91 mm
Net Weight 1165 grams
Shipping Weight (Calculated) 5.0 kg (with protective operational packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2030-0130 is positioned in the mid-high range of the CX modular family. System integrators should note that this unit requires a CX2100 series power supply module for direct power and bus interface capabilities. When replacing older single-core CX series systems, ensure that your TwinCAT licenses are migrated to Platform Level 60 (Mid Performance Plus) to accommodate the core licensing architecture of this dual-core processor.

Application Pitfalls & Engineering Notes

While the module features passive cooling as standard, thermal management is heavily dependent on ambient cabinet ventilation. In closed control panels with high heat dissipation components, ensure that the minimum mounting clearances of 30 mm above and below the module are maintained. Avoid configuring real-time cyclic tasks on both cores simultaneously without proper core isolation configuration in TwinCAT; dedicate Core 0 to general OS operations and Core 1 to real-time execution loops to prevent jitter and cycle overflows.

Commissioning & Wiring Tips

Always insert or remove the CFast card while the module is completely powered off to prevent file system corruption on the flash media. For industrial network setups with high EMC interference, route the dual RJ45 Ethernet cables separately from power wiring and use double-shielded (SF/UTP) CAT6 cabling. Grounding must be established securely via the DIN rail connection and the ground terminal on the companion power supply module.

Installation Guidelines

CRITICAL WARNING: Ensure all power to the main control panel and auxiliary power feeds is completely de-energized and locked out before attempting physical installation or electrical termination of this CPU module. Verify that the system's power supplies have completely discharged their internal capacitors to avoid damage to sensitive CMOS components.
1
Align the CPU module and the CX power supply module, snapping them together via the integrated side connector before mounting them on the rail.
2
Snap the assembled unit firmly onto a clean, grounded 35 mm DIN rail (EN 60715) and secure it with appropriate end brackets.
3
Connect the communication and I/O lines (DVI, USB, RJ45) before running the 24 V DC power wiring to the terminal block of the power supply module.

FAQ

What is the TwinCAT 3 platform level for this CPU module?

The CX2030-0130 operates at TwinCAT 3 Platform Level 60 (Mid Performance Plus). Ensure all runtime licenses are matching this level.

Does this module support both EtherCAT and standard Bus Terminals?

Yes. It supports direct connection to E-bus (EtherCAT Terminals) and K-bus (standard Bus Terminals) via an attached CX series power supply module, which performs automatic recognition of the terminal bus type.

What happens to process data during an unexpected power interruption?

This module features 128 kB of integrated non-volatile NOVRAM memory which automatically retains critical control variable states without requiring battery-backed UPS setups.

Is the system passive or active cooled?

The CPU module uses high-efficiency passive cooling as standard. Active fan cooling can be configured ex factory if operation in high-temperature environments is required.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.