Beckhoff EL3102 EtherCAT 2-Channel Analog input Terminal
SKU EL3102
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
BECKHOFF
Product No.:
EL3102
Country of origin:Germany
Product Type:
Analog Input Terminal
Payment:
T/T, Western Union
Weight:
60g
Dimensions:
68 mm x 12 mm x 100 mm (H x W x D)
Shipping port:
Xiamen
Warranty:
12 months
Description
The Beckhoff EL3102 is a 2-channel analog input terminal designed to process differential voltage signals in the range of -10 V to +10 V with a 16-bit resolution. Operating on the EtherCAT system protocol, this device digitizes analog measurement signals and transmits them electrically isolated to the higher-level automation system via the E-bus. It features integrated Distributed Clocks to enable precise, synchronous signal acquisition with high time accuracy across the network. Built-in processing options include standard and compact process images, switchable measuring data representation, activatable FIR/IIR digital filters, and limit value monitoring.
Features
Two differential analog voltage input channels (-10 V to +10 V)
16-bit resolution including sign for high-precision measurement
Distributed Clocks support with precision significantly under 1 us
Switchable measuring data representation and activatable FIR/IIR digital filters
Hardware-level limit value monitoring and standard/compact process image options
Galvanic isolation of 500 V between the E-bus and signal voltage
Applications
Multi-axis motion control requiring precise synchronous voltage feedback
High-accuracy sensor signal acquisition in industrial automation
High-speed test benches and signal monitoring systems
Process control systems using standardized -10 V to +10 V interfaces
DIN Rail Mounting: Install on a 35 mm DIN rail according to EN 60715. Engage the locking mechanism securely.
Side-by-Side Mounting: Join adjacent terminals using the integrated double slot and key connection system.
Wiring: Insert solid, stranded, or ferruled conductors into the spring-clamp terminals by actuating the mechanism with a screwdriver. Maintain a stripping length of 8 mm to 9 mm.
Environmental Considerations: Ensure the installation environment maintains protection class IP 20 standards and remains within operating limits (-25 degC to +60 degC, non-condensing).
Compliance and Certifications
CE
UL
ATEX: II 3 G Ex nA IIC T4 Gc
Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
FAQ
What is the resolution and input signal range of this module?
The device features a 16-bit resolution (including sign) and processes differential voltage signals in the range of -10 V to +10 V.
Does the device support Distributed Clocks functionality?
Yes, the module supports Distributed Clocks with a precision of significantly under 1 microsecond.
What is the conversion time for analog-to-digital signal processing?
The conversion time is approximately 60 microseconds under standard operation and approximately 40 microseconds in fast mode.
What is the operating temperature range for the terminal?
The device is designed to operate in ambient temperatures ranging from -25 degC to +60 degC.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.