Description

The BECKHOFF EL3174-0002 is a high-performance, 4-channel analog input EtherCAT Terminal designed for flexible voltage and current measurement. This multi-function terminal features electrically isolated differential inputs, allowing each channel to be individually parameterised through the control system to process either current or voltage signals. The exceptional 2500 V functional isolation between channels and to the fieldbus makes it an ideal choice for preventing ground loop problems and ensuring high signal integrity in complex electrical environments.

As part of the modular BECKHOFF EtherCAT I/O system, the EL3174-0002 integrates directly into standard terminal segments. It operates with 16-bit resolution and supports Distributed Clocks (DC) for precise synchronization of measurements across the entire control network. The combination of flexible parameterization, electrical isolation, and high-speed EtherCAT communication provides reliable data acquisition for demanding test, measurement, and control systems.

Features

  • Four analog input channels, with each channel individually parameterizable for voltage or current signals.
  • 2500 V functional isolation channel-to-channel and channel-to-fieldbus to eliminate ground loops.
  • 16-bit signal conversion resolution for precise measurements.
  • Supports Distributed Clocks (DC) for highly synchronized sampling across the network.
  • Compact 12 mm terminal housing width to minimize space requirements on the DIN rail.
  • Integrated diagnostic LEDs for real-time channel and system status monitoring.

Applications

  • Analog signal acquisition in multi-potential systems with high electrical isolation requirements.
  • Mixed voltage and current measurement in testing and laboratory environments.
  • Process control systems needing flexible, software-parameterised analog inputs.
  • Distributed automated manufacturing lines requiring synchronized analog data.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3174-0002
Product Type EtherCAT Terminal
Number of Inputs 4 differential inputs
Housing Width 12 mm

Electrical Data

Parameter Specification
Power Supply Via the E-bus
Current Consumption E-bus Typical 150 mA
Current Consumption Power Contacts No contact to power contacts
Electrical Isolation 2500 V functional isolation (channel/channel and channel/fieldbus)

Analog Inputs and Resolution

Parameter Specification
Measuring Range (Nominal) -10 to +10 V or -20 to +20 mA (including 0...10 V and 0/4...20 mA)
Measuring Range (Technical) -10.73 to +10.73 V or -21.47 to +21.47 mA
Resolution 16 bit (including sign)
Internal Resistance Greater than 200 kOhm (voltage) | Typical 85 Ohm (current)
Input Filter Limit Frequency 5 kHz
Conversion Time Minimum 150 microseconds
Measuring Error Less than +/-0.2% (at 25 degC +/-5 degC, relative to full scale)

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approximately 65 g
Mounting On 35 mm DIN rail (EN 60715) with lock
Connection Type CAGE CLAMP spring connection
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20
Approvals CE, UL, ATEX, IECEx, cFMus

Installation Guidelines

  1. Ensure that the entire system power supply is completely de-energized before mounting or removing terminals.
  2. Align the EL3174-0002 with the DIN rail and snap it onto the assembly, verifying that the lock is securely engaged.
  3. Slide the terminal together with adjacent terminals to establish correct E-bus contact connection.
  4. Connect the differential sensor wiring to the spring clamp contacts using a standard screwdriver. Ensure that signal shielding is correctly terminated.
  5. Power up the system and verify the statuses shown by the integrated diagnostics LEDs on the front of the terminal.

Configuration Guidelines

The EL3174-0002 does not require hardware switches or physical address settings. All settings, including signal type configuration (voltage or current) and filter adjustments, are performed through the EtherCAT master configuration tool or the TwinCAT System Manager using the standard XML-based EtherCAT System Information (ESI) file.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the key difference between the standard EL3174 and the BECKHOFF EL3174-0002?
The BECKHOFF EL3174-0002 features high channel-to-channel electrical isolation of 2500 V, whereas the standard EL3174 does not offer electrical isolation between individual input channels.
What input signal ranges can be configured on the BECKHOFF EL3174-0002?
Each of the four channels on the BECKHOFF EL3174-0002 can be configured individually for voltage ranges of -10 to +10 V (or 0 to 10 V) or current ranges of -20 to +20 mA (including 0 to 20 mA and 4 to 20 mA).
Does the BECKHOFF EL3174-0002 support Distributed Clocks?
Yes, the BECKHOFF EL3174-0002 supports Distributed Clocks (DC) with a precision of less than 1 microsecond, allowing synchronized input measurements across the control network.
Are any hardware configuration switches required for the BECKHOFF EL3174-0002?
No, the BECKHOFF EL3174-0002 is fully configured and parameterized via software in the TwinCAT System Manager or the EtherCAT master interface.
What wiring methods are supported by the BECKHOFF EL3174-0002?
The BECKHOFF EL3174-0002 uses spring-loaded CAGE CLAMP connections which support solid conductors, flexible conductors, and conductors with ferrules from 0.08 to 2.5 mm² (AWG 28 to 14).
Reviews

EL3174-0002

Stock & lead time on request

Call
1 of 1

BECKHOFF EL3174-0002 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3174-0002

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EL3174-0002 is a high-performance, 4-channel analog input EtherCAT Terminal designed for flexible voltage and current measurement. This multi-function terminal features electrically isolated differential inputs, allowing each channel to be individually parameterised through the control system to process either current or voltage signals. The exceptional 2500 V functional isolation between channels and to the fieldbus makes it an ideal choice for preventing ground loop problems and ensuring high signal integrity in complex electrical environments.

As part of the modular BECKHOFF EtherCAT I/O system, the EL3174-0002 integrates directly into standard terminal segments. It operates with 16-bit resolution and supports Distributed Clocks (DC) for precise synchronization of measurements across the entire control network. The combination of flexible parameterization, electrical isolation, and high-speed EtherCAT communication provides reliable data acquisition for demanding test, measurement, and control systems.

Features

  • Four analog input channels, with each channel individually parameterizable for voltage or current signals.
  • 2500 V functional isolation channel-to-channel and channel-to-fieldbus to eliminate ground loops.
  • 16-bit signal conversion resolution for precise measurements.
  • Supports Distributed Clocks (DC) for highly synchronized sampling across the network.
  • Compact 12 mm terminal housing width to minimize space requirements on the DIN rail.
  • Integrated diagnostic LEDs for real-time channel and system status monitoring.

Applications

  • Analog signal acquisition in multi-potential systems with high electrical isolation requirements.
  • Mixed voltage and current measurement in testing and laboratory environments.
  • Process control systems needing flexible, software-parameterised analog inputs.
  • Distributed automated manufacturing lines requiring synchronized analog data.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3174-0002
Product Type EtherCAT Terminal
Number of Inputs 4 differential inputs
Housing Width 12 mm

Electrical Data

Parameter Specification
Power Supply Via the E-bus
Current Consumption E-bus Typical 150 mA
Current Consumption Power Contacts No contact to power contacts
Electrical Isolation 2500 V functional isolation (channel/channel and channel/fieldbus)

Analog Inputs and Resolution

Parameter Specification
Measuring Range (Nominal) -10 to +10 V or -20 to +20 mA (including 0...10 V and 0/4...20 mA)
Measuring Range (Technical) -10.73 to +10.73 V or -21.47 to +21.47 mA
Resolution 16 bit (including sign)
Internal Resistance Greater than 200 kOhm (voltage) | Typical 85 Ohm (current)
Input Filter Limit Frequency 5 kHz
Conversion Time Minimum 150 microseconds
Measuring Error Less than +/-0.2% (at 25 degC +/-5 degC, relative to full scale)

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approximately 65 g
Mounting On 35 mm DIN rail (EN 60715) with lock
Connection Type CAGE CLAMP spring connection
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20
Approvals CE, UL, ATEX, IECEx, cFMus

Installation Guidelines

  1. Ensure that the entire system power supply is completely de-energized before mounting or removing terminals.
  2. Align the EL3174-0002 with the DIN rail and snap it onto the assembly, verifying that the lock is securely engaged.
  3. Slide the terminal together with adjacent terminals to establish correct E-bus contact connection.
  4. Connect the differential sensor wiring to the spring clamp contacts using a standard screwdriver. Ensure that signal shielding is correctly terminated.
  5. Power up the system and verify the statuses shown by the integrated diagnostics LEDs on the front of the terminal.

Configuration Guidelines

The EL3174-0002 does not require hardware switches or physical address settings. All settings, including signal type configuration (voltage or current) and filter adjustments, are performed through the EtherCAT master configuration tool or the TwinCAT System Manager using the standard XML-based EtherCAT System Information (ESI) file.

Loading product navigation…

What is the key difference between the standard EL3174 and the BECKHOFF EL3174-0002?

The BECKHOFF EL3174-0002 features high channel-to-channel electrical isolation of 2500 V, whereas the standard EL3174 does not offer electrical isolation between individual input channels.

What input signal ranges can be configured on the BECKHOFF EL3174-0002?

Each of the four channels on the BECKHOFF EL3174-0002 can be configured individually for voltage ranges of -10 to +10 V (or 0 to 10 V) or current ranges of -20 to +20 mA (including 0 to 20 mA and 4 to 20 mA).

Does the BECKHOFF EL3174-0002 support Distributed Clocks?

Yes, the BECKHOFF EL3174-0002 supports Distributed Clocks (DC) with a precision of less than 1 microsecond, allowing synchronized input measurements across the control network.

Are any hardware configuration switches required for the BECKHOFF EL3174-0002?

No, the BECKHOFF EL3174-0002 is fully configured and parameterized via software in the TwinCAT System Manager or the EtherCAT master interface.

What wiring methods are supported by the BECKHOFF EL3174-0002?

The BECKHOFF EL3174-0002 uses spring-loaded CAGE CLAMP connections which support solid conductors, flexible conductors, and conductors with ferrules from 0.08 to 2.5 mm² (AWG 28 to 14).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...