SKU EL3174

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EL3174

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF EL3174 is a four-channel analog input terminal designed for the EtherCAT I/O system. This multi-function terminal processes signals spanning voltage and current ranges, accommodating inputs such as plus/minus 10 V and plus/minus 20 mA with a 16-bit resolution. As part of the High-Density housing series, the device integrates four independent channels into a narrow 12 mm module width, making it well-suited for space-constrained control cabinets requiring multi-channel analog data acquisition.

The terminal features parameterizable input types, supporting both differential voltage measurements and single-ended current measurements. Equipped with distributed clock support capable of sub-microsecond precision, the EL3174 allows synchronized sampling across distributed automation nodes. It communicates process data via the EtherCAT E-bus, requiring no manual addressing or physical configuration switches during setup.

Features

  • Four independent analog input channels in a compact 12 mm High-Density housing
  • Parameterizable measuring ranges for voltage (-10/0 to +10 V) and current (-20/0/+4 to +20 mA)
  • 16-bit resolution including sign for high-precision measurement acquisition
  • Distributed clock support with precision under 1 microsecond for synchronized data acquisition
  • Selectable FIR and IIR input filters alongside ExtendedRange support
  • Standard and compact process image configurations for optimized data transfer
  • Signal status LEDs for visual channel and diagnostic monitoring

Applications

  • Precision analog sensor monitoring in industrial automation and machine control
  • Multi-channel voltage and current signal acquisition in test benches and laboratory setups
  • Synchronized data logging across distributed EtherCAT network topologies
  • Process monitoring applications requiring configurable filter characteristics and high resolution

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3174
Product Type EtherCAT Terminal
Number of Inputs 4
Design Form HD (High Density) housing with signal LEDs
Country of Origin Germany

Signal and I/O

Parameter Specification
Technology U differential, I single-ended
Signal Type Differential (voltage), Single-ended (current)
Nominal Measuring Range (Voltage) -10/0 to +10 V
Nominal Measuring Range (Current) -20/0/+4 to +20 mA
Technical Measuring Range (Voltage) -10.73 to +10.73 V
Technical Measuring Range (Current) -21.47 to +21.47 V
Resolution 16 bit (incl. sign)
Measuring Error < plus/minus 0.3 % (relative to full scale value)
Conversion Time Minimum 150 microseconds
Input Filter Limit Frequency 5 kHz
Internal Resistance > 200 kohm (voltage) | typ. 85 ohm (current)
Common-Mode Voltage (UCM) Max. 35 V (voltage measurement)
Dielectric Strength Max. 30 V (current measurement)

Electrical and Power

Parameter Specification
Power Supply Via the E-bus
Current Consumption E-bus Typ. 200 mA
Current Load Power Contacts Imax: 10 A
Electrical Isolation 500 V (E-bus / signal voltage)

Communication and Performance

Parameter Specification
Distributed Clocks Yes
Distributed Clock Precision << 1 microsecond
Bit Width in Process Image Inputs: 16 byte
Configuration No address or configuration setting required
Special Features U/I parameterizable, ExtendedRange, standard and compact process image, activatable FIR/IIR filters

Connection and Mechanical

Parameter Specification
Connection Technology Spring actuation by screwdriver
Solid Conductor Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Stranded Conductor Cross-Section 0.25 to 1.5 mm2 (AWG 22 to 16)
Conductor with Ferrule Cross-Section 0.14 to 0.75 mm2 (AWG 26 to 19)
Stripping Length 8 to 9 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 65 g
Mounting On 35 mm DIN rail conforming to EN 60715 with lock

Environmental and Compliance

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Relative Humidity 95 %, no condensation
Protection Rating IP20
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL, ATEX, IECEx, cFMus
Ex Marking (cFMus) Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, AEx ec IIC T4 Gc

Installation Guidelines

  1. Ensure the entire control system and associated power supplies are fully de-energized before beginning installation or wiring work.
  2. Inspect the BECKHOFF EL3174 terminal housing and connection points for any signs of transit damage.
  3. Mount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) by snapping it securely into place using the integrated locking mechanism. Ensure proper side-by-side engagement via the double slot and key connection.
  4. Strip field conductors to the recommended length of 8 to 9 mm. Insert solid, stranded, or ferrule-equipped wires into the spring-loaded connection points using a suitable screwdriver.
  5. Verify terminal assignment and signal wiring against system schematics, ensuring proper separation between differential voltage and single-ended current loops.
  6. Confirm that E-bus connections and power contact bridges are correctly seated between adjacent terminals.
  7. Restore system power and verify operational status using the integrated channel signal LEDs and the TwinCAT engineering environment.
Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.