Description

The BECKHOFF EL3351 is an EtherCAT Terminal featuring a single-channel analog input specifically designed for measuring bridge evaluation. Operating within the modular EtherCAT I/O system, this device enables direct connection of a resistive full bridge sensor, such as a strain gauge, allowing precise acquisition of load, force, or weight measurements in industrial automation environments.

Signal processing is handled with high resolution, and the integrated 5 V DC bridge supply powers the connected sensor directly through the terminal. The compact housing mounts easily onto a standard 35 mm DIN rail and communicates high-speed measurement data over the EtherCAT network with minimal latency.

Features

  • 1-channel analog input terminal for resistance bridges in full bridge technology
  • Integrated 5 V DC bridge supply for strain gauge sensors
  • Differential signal input with high internal resistance
  • Parameterizable input filter limit frequency with a 50 Hz default setting
  • Configurable conversion time supporting up to 400 samples per second
  • 16-bit resolution with 32-bit process value presentation
  • Powered via the internal E-bus without requiring additional field supply terminals for logic

Applications

  • Industrial weighing systems and platform scales
  • Force monitoring and load cell measurement in assembly machines
  • Strain and stress analysis on moving or static mechanical structures
  • Test benches and laboratory measurement setups requiring high-precision bridge evaluation

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3351
Product Type EtherCAT Terminal
Number of Inputs 1 (for 1 resistor bridge in full bridge technology)
Technology Resistor bridge, strain gauge
Signal Type Differential

Electrical Characteristics

Parameter Specification
Measuring Range UD Max. -20 to +20 mV
Measuring Range UREF Max. -12 to +12 V
Internal Resistance > 200 kΩ (UREF), > 1 MΩ (UD)
Power Supply UV 5 V DC, max. 20 mA (integrated bridge supply)
Power Supply Via the E-bus
Current Consumption E-Bus Typ. 170 mA
Current Load Power Contacts Imax: 10 A

Performance and Processing

Parameter Specification
Resolution 16 bit, 32 bit presentation
Input Filter Limit Frequency 50 Hz default setting, parameterizable
Conversion Time 2.5 to 800 ms, configurable, max. 400 samples/s
Measuring Error < ±0.1 % (relative to full scale value, 50 Hz filter)
Supported Nominal Sensitivity Calculated in PLC, freely selectable

Connection System

Parameter Specification
Connection Technology Spring actuation by screwdriver
Connection Cross-Section Solid 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section Stranded 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section with Ferrule 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Mounting On 35 mm DIN rail conforming to EN 60715
Protection Rating IP 20
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure all system power and field supplies are switched off and locked out before performing any mechanical or electrical work.
  2. Inspect the BECKHOFF EL3351 terminal for any visible transport damage or bent pins.
  3. Mount the terminal onto a standard 35 mm DIN rail by snapping it into place using the locking mechanism. Ensure proper side-by-side alignment with adjacent EtherCAT terminals or couplers via the slot and key connection.
  4. Connect the strain gauge full bridge sensor wiring to the appropriate terminal points using a suitable screwdriver for spring actuation, ensuring correct assignment of excitation and signal lines.
  5. Verify that the E-bus connection engages correctly with neighboring terminals to maintain power and data continuity across the bus coupler system.
  6. Restore system power and configure the terminal parameters within the TwinCAT engineering environment prior to operational use.

FAQ

What is the primary function of the BECKHOFF EL3351?

The BECKHOFF EL3351 is a 1-channel analog input EtherCAT Terminal designed for evaluating resistive full bridge sensors such as strain gauges in industrial measurement applications.

How is the BECKHOFF EL3351 powered during operation?

The BECKHOFF EL3351 receives its internal power supply via the E-bus without requiring an external logic power connection.

Does the BECKHOFF EL3351 provide excitation voltage for sensors?

Yes, the BECKHOFF EL3351 features an integrated 5 V DC bridge supply capable of delivering up to 20 mA to power connected measuring bridge sensors directly.

What is the resolution and conversion performance of the BECKHOFF EL3351?

The BECKHOFF EL3351 provides a 16-bit resolution with 32-bit process value presentation, and a configurable conversion time supporting up to 400 samples per second.

How does the BECKHOFF EL3351 mount into an automation system?

The BECKHOFF EL3351 mounts onto a standard 35 mm DIN rail conforming to EN 60715 and connects to adjacent modules using a side-by-side double slot and key connection.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.