BECKHOFF

BECKHOFF EL3351 EtherCAT Terminal

SKU EL3351

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EL3351
  • Origin Germany
  • Product Type: EtherCAT Terminals
  • Payment: T/T, Western Union
  • Weight: 0.06 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF EL3351 is an EtherCAT Terminal featuring a single-channel analog input specifically designed for measuring bridge evaluation. Operating within the modular EtherCAT I/O system, this device enables direct connection of a resistive full bridge sensor, such as a strain gauge, allowing precise acquisition of load, force, or weight measurements in industrial automation environments.

Signal processing is handled with high resolution, and the integrated 5 V DC bridge supply powers the connected sensor directly through the terminal. The compact housing mounts easily onto a standard 35 mm DIN rail and communicates high-speed measurement data over the EtherCAT network with minimal latency.

Features

  • 1-channel analog input terminal for resistance bridges in full bridge technology
  • Integrated 5 V DC bridge supply for strain gauge sensors
  • Differential signal input with high internal resistance
  • Parameterizable input filter limit frequency with a 50 Hz default setting
  • Configurable conversion time supporting up to 400 samples per second
  • 16-bit resolution with 32-bit process value presentation
  • Powered via the internal E-bus without requiring additional field supply terminals for logic

Applications

  • Industrial weighing systems and platform scales
  • Force monitoring and load cell measurement in assembly machines
  • Strain and stress analysis on moving or static mechanical structures
  • Test benches and laboratory measurement setups requiring high-precision bridge evaluation

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3351
Product Type EtherCAT Terminal
Number of Inputs 1 (for 1 resistor bridge in full bridge technology)
Technology Resistor bridge, strain gauge
Signal Type Differential

Electrical Characteristics

Parameter Specification
Measuring Range UD Max. -20 to +20 mV
Measuring Range UREF Max. -12 to +12 V
Internal Resistance > 200 kΩ (UREF), > 1 MΩ (UD)
Power Supply UV 5 V DC, max. 20 mA (integrated bridge supply)
Power Supply Via the E-bus
Current Consumption E-Bus Typ. 170 mA
Current Load Power Contacts Imax: 10 A

Performance and Processing

Parameter Specification
Resolution 16 bit, 32 bit presentation
Input Filter Limit Frequency 50 Hz default setting, parameterizable
Conversion Time 2.5 to 800 ms, configurable, max. 400 samples/s
Measuring Error < ±0.1 % (relative to full scale value, 50 Hz filter)
Supported Nominal Sensitivity Calculated in PLC, freely selectable

Connection System

Parameter Specification
Connection Technology Spring actuation by screwdriver
Connection Cross-Section Solid 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section Stranded 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section with Ferrule 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Mounting On 35 mm DIN rail conforming to EN 60715
Protection Rating IP 20
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure all system power and field supplies are switched off and locked out before performing any mechanical or electrical work.
  2. Inspect the BECKHOFF EL3351 terminal for any visible transport damage or bent pins.
  3. Mount the terminal onto a standard 35 mm DIN rail by snapping it into place using the locking mechanism. Ensure proper side-by-side alignment with adjacent EtherCAT terminals or couplers via the slot and key connection.
  4. Connect the strain gauge full bridge sensor wiring to the appropriate terminal points using a suitable screwdriver for spring actuation, ensuring correct assignment of excitation and signal lines.
  5. Verify that the E-bus connection engages correctly with neighboring terminals to maintain power and data continuity across the bus coupler system.
  6. Restore system power and configure the terminal parameters within the TwinCAT engineering environment prior to operational use.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF EL3351?
The BECKHOFF EL3351 is a 1-channel analog input EtherCAT Terminal designed for evaluating resistive full bridge sensors such as strain gauges in industrial measurement applications.
How is the BECKHOFF EL3351 powered during operation?
The BECKHOFF EL3351 receives its internal power supply via the E-bus without requiring an external logic power connection.
Does the BECKHOFF EL3351 provide excitation voltage for sensors?
Yes, the BECKHOFF EL3351 features an integrated 5 V DC bridge supply capable of delivering up to 20 mA to power connected measuring bridge sensors directly.
What is the resolution and conversion performance of the BECKHOFF EL3351?
The BECKHOFF EL3351 provides a 16-bit resolution with 32-bit process value presentation, and a configurable conversion time supporting up to 400 samples per second.
How does the BECKHOFF EL3351 mount into an automation system?
The BECKHOFF EL3351 mounts onto a standard 35 mm DIN rail conforming to EN 60715 and connects to adjacent modules using a side-by-side double slot and key connection.
Reviews

EL3351

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF EL3351 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3351

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EL3351 is an EtherCAT Terminal featuring a single-channel analog input specifically designed for measuring bridge evaluation. Operating within the modular EtherCAT I/O system, this device enables direct connection of a resistive full bridge sensor, such as a strain gauge, allowing precise acquisition of load, force, or weight measurements in industrial automation environments.

Signal processing is handled with high resolution, and the integrated 5 V DC bridge supply powers the connected sensor directly through the terminal. The compact housing mounts easily onto a standard 35 mm DIN rail and communicates high-speed measurement data over the EtherCAT network with minimal latency.

Features

  • 1-channel analog input terminal for resistance bridges in full bridge technology
  • Integrated 5 V DC bridge supply for strain gauge sensors
  • Differential signal input with high internal resistance
  • Parameterizable input filter limit frequency with a 50 Hz default setting
  • Configurable conversion time supporting up to 400 samples per second
  • 16-bit resolution with 32-bit process value presentation
  • Powered via the internal E-bus without requiring additional field supply terminals for logic

Applications

  • Industrial weighing systems and platform scales
  • Force monitoring and load cell measurement in assembly machines
  • Strain and stress analysis on moving or static mechanical structures
  • Test benches and laboratory measurement setups requiring high-precision bridge evaluation

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model EL3351
Product Type EtherCAT Terminal
Number of Inputs 1 (for 1 resistor bridge in full bridge technology)
Technology Resistor bridge, strain gauge
Signal Type Differential

Electrical Characteristics

Parameter Specification
Measuring Range UD Max. -20 to +20 mV
Measuring Range UREF Max. -12 to +12 V
Internal Resistance > 200 kΩ (UREF), > 1 MΩ (UD)
Power Supply UV 5 V DC, max. 20 mA (integrated bridge supply)
Power Supply Via the E-bus
Current Consumption E-Bus Typ. 170 mA
Current Load Power Contacts Imax: 10 A

Performance and Processing

Parameter Specification
Resolution 16 bit, 32 bit presentation
Input Filter Limit Frequency 50 Hz default setting, parameterizable
Conversion Time 2.5 to 800 ms, configurable, max. 400 samples/s
Measuring Error < ±0.1 % (relative to full scale value, 50 Hz filter)
Supported Nominal Sensitivity Calculated in PLC, freely selectable

Connection System

Parameter Specification
Connection Technology Spring actuation by screwdriver
Connection Cross-Section Solid 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section Stranded 0.08 to 2.5 mm² (AWG 28 to 14)
Connection Cross-Section with Ferrule 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 60 g
Mounting On 35 mm DIN rail conforming to EN 60715
Protection Rating IP 20
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure all system power and field supplies are switched off and locked out before performing any mechanical or electrical work.
  2. Inspect the BECKHOFF EL3351 terminal for any visible transport damage or bent pins.
  3. Mount the terminal onto a standard 35 mm DIN rail by snapping it into place using the locking mechanism. Ensure proper side-by-side alignment with adjacent EtherCAT terminals or couplers via the slot and key connection.
  4. Connect the strain gauge full bridge sensor wiring to the appropriate terminal points using a suitable screwdriver for spring actuation, ensuring correct assignment of excitation and signal lines.
  5. Verify that the E-bus connection engages correctly with neighboring terminals to maintain power and data continuity across the bus coupler system.
  6. Restore system power and configure the terminal parameters within the TwinCAT engineering environment prior to operational use.
Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF EL3351?

The BECKHOFF EL3351 is a 1-channel analog input EtherCAT Terminal designed for evaluating resistive full bridge sensors such as strain gauges in industrial measurement applications.

How is the BECKHOFF EL3351 powered during operation?

The BECKHOFF EL3351 receives its internal power supply via the E-bus without requiring an external logic power connection.

Does the BECKHOFF EL3351 provide excitation voltage for sensors?

Yes, the BECKHOFF EL3351 features an integrated 5 V DC bridge supply capable of delivering up to 20 mA to power connected measuring bridge sensors directly.

What is the resolution and conversion performance of the BECKHOFF EL3351?

The BECKHOFF EL3351 provides a 16-bit resolution with 32-bit process value presentation, and a configurable conversion time supporting up to 400 samples per second.

How does the BECKHOFF EL3351 mount into an automation system?

The BECKHOFF EL3351 mounts onto a standard 35 mm DIN rail conforming to EN 60715 and connects to adjacent modules using a side-by-side double slot and key connection.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.