To integrate standard legacy fieldbus communication into modern control networks, the Beckhoff EL6731-0010 acts as a dedicated PROFIBUS DP slave terminal within the modular EtherCAT Terminal system. This compact terminal enables direct communication between an EtherCAT network master and any upstream PROFIBUS DP master controller. Incorporating an optimized, non-volatile memory structure, the device offers highly flexible cyclic data exchange capacities, accommodating process images up to 1.4 kbytes of input and 1.4 kbytes of output data. By mapping PROFIBUS diagnostics, configuration parameters, and alarm states directly to the EtherCAT process image, it ensures high diagnostic transparency and seamless cross-platform control synchronization.

Features

  • Multi-Protocol Support: Seamlessly processes PROFIBUS DP, DP-V1 (Class 1 and 2 acyclic services, alarms), DP-V2, and equidistant PROFIBUS MC configurations.
  • Broad Baud Rate Spectrum: Auto-detects and supports transmission rates ranging from 9.6 kbaud up to 12 Mbaud.
  • Galvanic Isolation: Embedded 1 x D-sub 9-pin interface is galvanically isolated to guard the internal E-bus circuitry from fieldbus transient noise.
  • CDL Concept Capability: Supports differing DP cycle times per slave using standard control data link technology.
  • Integrated Status Diagnostics: Onboard LED indicators display real-time physical layer, protocol, and connection health.

Applications

  • Legacy PLC Integration: Linking legacy Siemens S7 or third-party PROFIBUS DP master PLCs into central Beckhoff EtherCAT networks.
  • Distributed Control Architecture: Bridging secondary conveyor lines, processing skids, or paint booths equipped with PROFIBUS field devices into an EtherCAT ring topology.
  • Process Industry Automation: Integrating hazardous-area standard process instruments using DP-V1/DP-V2 diagnostic profiles.

Technical Specifications

Specification Value
Manufacturer Beckhoff Automation
Model Number EL6731-0010
Fieldbus Type PROFIBUS DP, DP-V1, DP-V2, PROFIBUS MC
Data Transfer Rates 9.6 kbaud to 12 Mbaud
Interface Type 1 x D-sub socket, 9-pin, galvanically decoupled
Process Image Memory Max. 1.4 kbyte input / 1.4 kbyte output data
E-bus Current Consumption Typical 350 mA
Operating Temperature -25 to +60 degC (no condensation)
Storage Temperature -40 to +85 degC
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Housing Material Polycarbonate (compact terminal housing)
Protection Class IP20
Environmental Standards Conforms to EN 60068-2-6 (Vibration) and EN 60068-2-27 (Shock)
Approvals & Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)
Net Weight 70 g
Shipping Weight (Calculated) 0.25 kg

Connections and Interfaces

D-Sub 9-Pin Connector Signal Assignment Description
Pin 3 RxD/TxD-P Receive/Transmit Data - Positive (B-Line, Red)
Pin 5 DGND Data Ground (Reference potential for VP)
Pin 6 VP Supply Voltage Plus (+5V for terminating resistors)
Pin 8 RxD/TxD-N Receive/Transmit Data - Negative (A-Line, Green)
Metal Frame Shield Functional Earth Shielding Connection

Empirical Engineering Insights

Alternative Models & Compatibility

Do not confuse the EL6731-0010 (Slave module) with the standard EL6731 (Master/Scanner module). While both share the same physical 24 mm housing, their firmware profiles are entirely different. The EL6731-0010 is addressed in TwinCAT exclusively as an EtherCAT-to-PROFIBUS slave box, requiring a GSD file for configuration on the upstream master controller.

Application Pitfalls & Engineering Notes

Since this terminal lacks physical rotary switches for manual PROFIBUS slave address setting, the node address must be assigned programmatically through the TwinCAT System Manager via the EtherCAT CoE (CoE index 0xF800:01) or standard GSD assignment. If using multiple high-draw communication cards on a single E-bus rail segment, carefully track your cumulative E-bus current. The EL6731-0010 draws a substantial 350 mA, meaning you may need an EL9410 power supply booster terminal on the right-hand side of the segment to avoid voltage drops.

Commissioning & Wiring Tips

To prevent high-frequency reflections and transmission errors, ensure that standard active RS485 termination is enabled at the end of the physical PROFIBUS line. The internal DB9 port of the EL6731-0010 provides +5V (Pin 6) and DGND (Pin 5) to supply a standard active termination connector. Always ground the DIN rail reliably to allow the terminal's rear grounding contact spring to discharge electrical noise efficiently.

Installation Guidelines

CRITICAL WARNING Disconnect the entire 24V DC bus and E-bus control power supplies before sliding, inserting, or removing the EL6731-0010 terminal. Failure to do so can cause electrostatic damage or permanently damage the internal E-bus contacts of neighboring EtherCAT terminals.
1
Align the EL6731-0010 on the 35 mm DIN rail (EN 60715) alongside your existing EtherCAT coupler or processor terminal.
2
Press the module firmly onto the rail until the latching locking mechanism clicks securely, ensuring continuous electrical contact of the rear E-bus terminal pins.
3
Insert the standard shielded 9-pin D-sub PROFIBUS connector and secure its retaining screws to minimize vibration susceptibility.
4
Turn on system power, scan the network inside TwinCAT, and verify that the physical state LEDs indicate proper communication synchrony.
Loading product navigation…

What is the primary technical difference between the Beckhoff EL6731 and the EL6731-0010?

The standard EL6731 acts as a PROFIBUS master (scanner) designed to manage up to 125 slaves. The EL6731-0010 operates exclusively as a PROFIBUS slave node, allowing an upstream third-party master controller to read/write process values to the local EtherCAT system.

How is the PROFIBUS station address configured for the EL6731-0010?

There are no physical hardware rotary or DIP switches. The station address is configured via TwinCAT System Manager software, where it is mapped through the EtherCAT CoE (CANopen over EtherCAT) settings under index 0xF800.

Does the EL6731-0010 support DP-V1 acyclic read/write commands?

Yes, it fully supports PROFIBUS DP-V1 (Class 1 and Class 2) acyclic communication, enabling the transfer of acyclic parameters, alarm messages, and extended diagnostics.

What are the E-bus power requirements for this terminal?

The module draws a typical current of 350 mA from the internal E-bus power rail. Ensure your EtherCAT coupler or power injection terminal (such as EL9410) can support this additional current.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...