1 of 1

BECKHOFF EL6752-0010 EtherCAT Terminal DeviceNet Slave

BECKHOFF EL6752-0010 EtherCAT Terminal DeviceNet Slave

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL6752-0010

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 70g

  • Dimensions: 24 mm x 100 mm x 52 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To integrate modern control environments with existing network standards, the EL6752-0010 functions as a high-performance DeviceNet slave gateway designed for the EtherCAT Terminal system. This 1-channel communication interface enables high-speed data transfer and process image synchronization between an EtherCAT master and a primary DeviceNet master. Configured specifically as a DeviceNet slave, it allows seamless data exchange while keeping the networks galvanically isolated to prevent industrial noise and electrical interference from damaging sensitive controller electronics.

Housed in a compact 24 mm housing with standard signal LEDs for real-time status diagnostics, this module provides a reliable physical interface via a 5-pin open style connector. Integrating natively within the TwinCAT engineering environment, the terminal is engineered for rugged deployment in automated process environments requiring mixed-protocol network layouts.

Features

  • 1-channel fieldbus interface acting as a DeviceNet slave
  • Supported transmission rates of 125, 250, and 500 kbaud
  • Galvanically decoupled 5-pin open style physical connection
  • Status diagnostics through integrated hardware LEDs
  • Compact terminal design optimized for DIN rail mounting space
  • Direct integration with Beckhoff EtherCAT network architectures

Applications

  • Integration of legacy DeviceNet field devices into EtherCAT networks
  • Automotive manufacturing and assembly production lines
  • Material handling systems and distribution facilities
  • Process control systems and water treatment plants

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL6752-0010
Technology DeviceNet slave terminal
Fieldbus DeviceNet
Number of Channels 1
Data Transfer Rates 125, 250, 500 kbaud
Interface 5-pin open style connector (galvanically decoupled)
Current Consumption E-bus typ. 260 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Housing Material Polycarbonate
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Weight approx. 70 g
Wiring Connection Push-in connection

Connections and Interfaces

Connector Pin Function
Pin 1 V- (Power supply ground)
Pin 2 CAN_L (CAN low signal)
Pin 3 Shield (Drain/Shield wire)
Pin 4 CAN_H (CAN high signal)
Pin 5 V+ (DeviceNet network power)

Installation Guidelines

  • Mount the terminal onto a 35 mm DIN rail conforming to EN 60715, ensuring the integrated lock is fully engaged.
  • Utilize the built-in double slot and key connection system when mounting side-by-side with other EtherCAT terminals to secure E-bus power and data contacts.
  • Ensure fieldbus cabling is routed away from high-voltage motor lines to reduce risk of electromagnetic interference.
  • Maintain sufficient panel ventilation space to keep ambient temperatures within the designated operating limit of -25 degC to +60 degC.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the primary function of the Beckhoff EL6752-0010?

The Beckhoff EL6752-0010 functions as a 1-channel DeviceNet slave terminal, allowing a primary DeviceNet master to communicate and exchange I/O data directly with an EtherCAT terminal system.

What communication baud rates are supported by this module?

The module supports standard DeviceNet transfer rates of 125 kbaud, 250 kbaud, and 500 kbaud.

Is the 5-pin open style connector included with the module?

Yes, the 5-pin open style connector according to DeviceNet specifications is supplied with the terminal.

What are the environmental operating limits for the EL6752-0010?

The module operates reliably within a temperature range of -25 degC to +60 degC and with a maximum non-condensing relative humidity of 95%.

Does this terminal support hazardous area installations?

Yes, the EL6752-0010 features ATEX approval with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...