Beckhoff EL9222-4433 EtherCAT Terminal 2-Channel Overcurrent Protection Module

Beckhoff EL9222-4433 EtherCAT Terminal 2-Channel Overcurrent Protection Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL9222-4433

  • Country of origin:Germany

  • Product Type: Overcurrent Protection Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to safeguard critical 24 V DC control circuits within EtherCAT industrial networks, the Beckhoff EL9222-4433 provides precise electronic overcurrent protection for dual channels rated at 3 A each. Operating directly within the standard EtherCAT terminal segment, this module dynamically monitors load currents, offering rapid electronic shutdown in the event of an overload or short circuit, thereby limiting system downtime. It features integrated status LEDs and physical push-buttons on the housing for immediate channel-level diagnostics and manual reset capability, while feeding complete diagnostic telemetry back to the controller via the E-bus interface.

Features

  • Dual-Channel Monitoring: Two independent 24 V DC distribution paths, limiting maximum current to 3 A per channel.
  • Hardware Redundancy: Integrated 4 A slow-blow fail-safe backup fuses provide hardware-level backup protection.
  • E-Bus Telemetry: Seamless configuration, current monitoring, and diagnostic reporting directly through TwinCAT.
  • Local Interactivity: Dedicated LED push-buttons on the terminal face allow for direct manual reset and instant physical status feedback.
  • High Packing Density: Compact 12 mm modular housing width minimizes DIN-rail footprint in control panels.

Applications

  • Sensor/Actuator Power Distribution: Safe current-limited supply routing for decentralized field sensors and valve terminals.
  • Control Cabinet Sub-Circuit Protection: Isolation of critical low-voltage hardware to prevent system-wide voltage collapses during single-point field faults.
  • EtherCAT Segment Protection: Protection of downstream auxiliary power contacts across I/O nodes.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number EL9222-4433
Nominal Operating Voltage 24 V DC
Number of Channels 2
Rated Current 3 A per channel
Max. Input Supply Current 10 A
Current Consumption (E-bus) 80 mA typical
Electrical Isolation 500 V (E-bus to signal voltage)
Backup Fail-Safe Element 4 A slow-blow (T) / 4 A slow-blow (T)
Overvoltage Cut-off >= 32 V DC
Hold After Trip-Out >= 10 s
Advance Load Warning Threshold 90 percent of rated channel load
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Enclosure Protection Rating IP20
Housing Material Polycarbonate
Physical Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight 55 g
Shipping Weight (Calculated) 2.0 kg
Certifications and Approvals CE, cULus, cURus

Connections & Interface Terminal Guide

Terminal Contact Wiring Specifications & Signal Mapping
Solid Conductor Range 0.08 to 2.5 mm² (AWG 28 to 14) via screwdriver spring actuation
Stranded Conductor Range 0.08 to 2.5 mm² (AWG 28 to 14)
Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Depth 8 to 9 mm
Power Contact Rating Imax: 10 A (Output 1 utilizes internal power contact path)

Empirical Engineering Insights

Alternative Models & Compatibility

The EL9222-4433 is optimized for 3 A fixed current limits per channel. For variable current configurations, look to the adjustable EtherCAT terminals (such as the EL9224). When inserting this module into an existing I/O stack, ensure that your TwinCAT EtherCAT XML Device Description (ESI) files are updated to match the specific firmware revision. If replacing an older EL9222-0000, verify that your E-bus current budget can handle the 80 mA load of the EL9222-4433.

Application Pitfalls & Engineering Notes

The absolute maximum capacity of the power contact rail is 10 A. Continuous heavy loads across multiple downstream modules must be calculated to prevent overload of the power contacts. If your segment exceeds 10 A total, you must insert an EL9100 or EL9110 power feed terminal directly upstream to segment the power contacts and prevent local terminal overheating.

Commissioning & Wiring Tips

To avoid intermittent faults, adhere strictly to the 8 to 9 mm stripping length. Under-stripping causes insecure mechanical tension clamp engagement, while over-stripping risks exposing bare wire to adjacent, closely-spaced terminals. When commissioning from TwinCAT, remember to map the CoE (CanOverEtherCAT) objects to read historical trip data and clear fault states remotely.

Installation Guidelines

CRITICAL WARNING:

De-energize the entire segment and isolate all 24 V DC power feeds before installing or removing the overcurrent protection terminal. Failure to do so may damage the E-bus connection pins, disrupt network communications, or lead to accidental arc discharges across adjacent contacts.

1
Align the EL9222-4433 terminal with the 35 mm DIN rail (conforming to EN 60715) alongside the existing EtherCAT segment. Ensure the slot and key guides line up correctly.
2
Press the terminal firmly onto the DIN rail until you hear the locking latch snap into position, securing the E-bus connections.
3
Using a standard terminal screwdriver, actuate the spring-actuated clamp connections to insert conductors stripped to 8-9 mm. Re-verify the wire cross-section conforms to AWG 28-14 (solid/stranded) or AWG 26-16 (ferrule).
4
Apply 24 V DC control power, boot the TwinCAT system, and verify that the front status LEDs illuminate green, indicating normal channel conditions.
Loading product navigation…

What is the primary function of the LED buttons on this terminal?

The integrated LED buttons serve a dual purpose: they physically display channel status (overload, tripped, or normal) and allow for direct local manual channel resetting during troubleshooting or maintenance.

Does this module require a separate power feed terminal?

The module uses standard 24 V DC power contacts. If the total cumulative current of your EtherCAT segment's power contacts exceeds 10 A, an upstream feed module like the EL9100 must be integrated to isolate and protect the bus.

Can I configure custom trip currents for the channels?

No, the EL9222-4433 features preset, hardware-defined tripping curves configured for a maximum of 3 A per channel. For adjustable configurations, look to programmable alternatives like the EL9224.

What is the required hold time after an overcurrent trip before resetting?

To prevent immediate thermal stress, there is a built-in thermal cooldown lockout requiring at least 10 seconds after a channel switches off before a reset can be triggered.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...