BECKHOFF

BECKHOFF ELX3312-0090 EtherCAT Terminal

SKU ELX3312-0090

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: ELX3312-0090

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF ELX3312-0090 is a high-precision, 2-channel analog input EtherCAT Terminal designed for direct temperature measurement using thermocouples located in explosion-hazardous areas. Featuring intrinsic safety (Ex i) interfaces, this terminal permits the direct connection of sensors installed in Zone 0/20 and Zone 1/21 hazardous environments, providing a highly integrated solution for process technology applications.

In addition to its intrinsically safe capabilities, the BECKHOFF ELX3312-0090 incorporates TwinSAFE SC (Single Channel) technology. This enables the use of standard analog signals for safety-directed tasks within a TwinSAFE system, allowing the transmission of process data to a TwinSAFE Logic terminal for safety-related evaluation and processing.

This compact 12 mm terminal supports a wide array of thermocouple types, performing high-resolution, low-noise analog-to-digital conversion. To maintain isolation and safety parameters, the terminal must be integrated into an EtherCAT segment powered by an ELX9560 power supply terminal.

Features

  • Intrinsically safe (Ex i) inputs for direct connection of field devices in hazardous locations
  • TwinSAFE SC (Single Channel) technology for safety-oriented process data evaluation
  • Two differential analog input channels dedicated to high-accuracy thermocouple measurement
  • Wide sensor compatibility supporting thermocouple types K, J, L, E, T, N, U, B, R, S, and C
  • High-resolution 16-bit analog-to-digital conversion
  • Integrated cold junction temperature compensation and characteristic curve linearization
  • Compact DIN rail mounting with diagnostics indicators via integrated LEDs

Applications

  • Intrinsically safe temperature monitoring in chemical, petrochemical, and gas processing plants
  • Thermocouple signal acquisition from Zone 0/20 and Zone 1/21 hazardous zones
  • Safety-related temperature monitoring systems using TwinSAFE SC architectures
  • Process engineering automation requiring compact, hazardous-area-compliant I/O solutions

Technical Specifications

General

Manufacturer BECKHOFF
Exact Model ELX3312-0090
Product Type EtherCAT Terminal
Number of Inputs 2 differential inputs
Connection Technology 2-wire

Signal and Measurement

Sensor Types Supported Thermocouples Type K, J, L, E, T, N, U, B, R, S, C (Default: Type K)
Measuring Range Depending on sensor type (Default Type K: -200 to +1350 degC)
Resolution 16 bit (0.1 degC per digit)
Measuring Error Less than +/-0.3% (relative to full scale value)
Internal Resistance Typ. >= 10 kOhm (differential)
Conversion Time 10 ms to 5000 ms (Adjustable, Default: 270 ms)

Electrical

Supply Voltage Electronics 24 V DC via power contacts (Requires ELX9560 power supply)
Current Consumption E-Bus Typ. 70 mA
Current Consumption Power Contacts Typ. 10 mA

Mechanical and Environmental

Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 60 g
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, no condensation
Protection Class IP20

Installation Guidelines

  1. Ensure all power supplies are fully de-energized before mounting, wiring, or configuring the terminal.
  2. Mount the terminal on a standard 35 mm DIN rail (EN 60715) with secure locking.
  3. Verify that the terminal is positioned within an EtherCAT Terminal segment that is powered downstream of an approved ELX9560 power supply terminal to ensure intrinsically safe power distribution.
  4. Observe all mandatory Ex i isolation distances, separation guidelines, and wiring classifications for hazardous-area installations.
  5. Ensure correct thermocouple polarity during wiring to avoid measurement offset and errors. Ensure shield grounding is executed in accordance with local hazardous area regulations.

FAQ

What is the primary function of the BECKHOFF ELX3312-0090?

The BECKHOFF ELX3312-0090 is a 2-channel analog input EtherCAT Terminal designed to perform high-resolution temperature measurements via thermocouples directly connected to sensors located in explosion-hazardous areas (Zone 0/20 and Zone 1/21).

Does the BECKHOFF ELX3312-0090 support safety functions?

Yes, the BECKHOFF ELX3312-0090 features TwinSAFE SC (Single Channel) technology, which allows standard analog process signals to be transmitted safely to a TwinSAFE Logic terminal for safety-directed evaluation.

Which thermocouple types are compatible with the BECKHOFF ELX3312-0090?

The BECKHOFF ELX3312-0090 supports thermocouple types K, J, L, E, T, N, U, B, R, S, and C, with type K configured as the default standard sensor.

Is an external power supply required for the BECKHOFF ELX3312-0090?

Yes, the BECKHOFF ELX3312-0090 must be supplied with power through an ELX9560 power supply terminal to ensure compliance with intrinsically safe (Ex i) power distribution standards.

What are the Ex i certifications for the BECKHOFF ELX3312-0090?

The BECKHOFF ELX3312-0090 is certified for use in hazardous areas under ATEX, IECEx, and cFMus regulations, with specific markings including Ex ec [ia Ga] IIC T4 Gc and [Ex ia Da] IIIC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.