BECKHOFF

BECKHOFF EPP1258-0002 EtherCAT P Box Digital Input Module

SKU EPP1258-0002

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EPP1258-0002
  • Origin Germany
  • Product Type: EtherCAT P Boxes
  • Payment: T/T, Western Union
  • Weight: 0.165 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF EPP1258-0002 is an EtherCAT P Box module designed for acquiring digital signals from the field level. This IP67-rated industrial I/O device features eight digital inputs operating at 24 V DC, with two of these inputs (channels 0 and 1) offering high-precision timestamping capabilities. The timestamp function enables precise recording of signal edges with a resolution of 1 ns, making it ideal for high-speed capture and precise synchronization across EtherCAT P networks.

By combining communication and power into a single cable (EtherCAT P), the BECKHOFF EPP1258-0002 reduces cabling complexity, lowers installation overhead, and minimizes the physical footprint required for decentralized I/O structures. It integrates Distributed Clocks technology, ensuring sub-microsecond synchronization with other devices on the EtherCAT network.

Features

  • Eight digital inputs (24 V DC) for collecting field sensor data
  • Two timestamp-enabled inputs (channels 0 and 1) with 1 ns resolution
  • Single-cable EtherCAT P technology integrating data and power (US/UP)
  • Standard M12 input connections and P-coded M8 bus interfaces
  • Integrated Distributed Clocks (DC) for precise system-wide synchronization
  • Protected design with IP65, IP66, and IP67 environmental protection ratings
  • Built-in sensor supply protection against short circuits

Applications

  • High-speed parts detection and registration mark sensing
  • Decentralized signal acquisition in packaging and assembly machines
  • Industrial robotics and automated handling systems
  • Precise event timing and edge detection in motion control setups

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Exact Model EPP1258-0002
Product Type EtherCAT P Box (Digital Input)
Number of Inputs 8 (2 with timestamping)
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter 10 us
Signal Voltage "0" -3 to +5 V (similar to EN 61131-2, type 3)
Signal Voltage "1" 11 to 30 V (similar to EN 61131-2, type 3)
Nominal Input Current typ. 3 mA (similar to EN 61131-2, type 3)
Distributed Clocks Yes
Timestamp Resolution 1 ns (channels 0 and 1)
Timestamp Precision 10 ns (+ input delay)
Sensor Supply From US (control voltage), max. 0.5 A total, short-circuit proof
Bus Interface 2 x M8 socket, shielded, screw type, P-coded (EtherCAT P)
Input Connection M12, 5-pin, A-coded
Current Consumption from US typ. 100 mA
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 165 g
Approvals CE, UL

Connections / Interfaces

Interface Function
M8 Sockets (P-coded) EtherCAT P input and output connection, transmitting both communication and supply voltage
M12 Sockets (5-pin, A-coded) Sensor input connections, supporting up to two channels per socket with integrated sensor supply

Installation Guidelines

  1. Ensure the system power supply is completely de-energized before mounting or wiring.
  2. Securely mount the EPP1258-0002 module to the machine frame using appropriate mounting screws.
  3. Connect the EtherCAT P cables to the P-coded M8 bus sockets. Hand-tighten and torque to specification to ensure IP65/66/67 sealing integrity.
  4. Attach the sensor cables to the M12 sockets, verifying proper pin alignment for the A-coded connectors.
  5. Ensure the total sensor current draw from the module does not exceed the rated 0.5 A limit.
  6. Scan the network within TwinCAT System Manager, import the device's ESI XML file if necessary, and map the corresponding process data.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the main function of the BECKHOFF EPP1258-0002?
The BECKHOFF EPP1258-0002 is an EtherCAT P Box designed to collect eight 24 V DC digital signals from field-level sensors, with two of these inputs featuring high-precision timestamping functionality for accurate edge-detection applications.
Which channels on the BECKHOFF EPP1258-0002 support timestamping?
On the BECKHOFF EPP1258-0002, channels 0 and 1 support timestamping, providing a measurement resolution of 1 ns and sub-microsecond synchronization via Distributed Clocks.
What type of connection technology does the BECKHOFF EPP1258-0002 use?
The BECKHOFF EPP1258-0002 uses P-coded M8 sockets for its EtherCAT P bus communication and power connection, and 5-pin, A-coded M12 sockets for connecting field sensors.
Is the sensor supply on the BECKHOFF EPP1258-0002 protected against short circuits?
Yes, the BECKHOFF EPP1258-0002 supplies connected sensors with control voltage (US) up to a maximum total current of 0.5 A, and this sensor supply is fully short-circuit proof.
Reviews

EPP1258-0002

Stock & lead time on request

Call
1 of 1

BECKHOFF EPP1258-0002 EtherCAT P Box Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPP1258-0002

  • Country of origin:Germany

  • Product Type: EtherCAT P Boxes

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF EPP1258-0002 is an EtherCAT P Box module designed for acquiring digital signals from the field level. This IP67-rated industrial I/O device features eight digital inputs operating at 24 V DC, with two of these inputs (channels 0 and 1) offering high-precision timestamping capabilities. The timestamp function enables precise recording of signal edges with a resolution of 1 ns, making it ideal for high-speed capture and precise synchronization across EtherCAT P networks.

By combining communication and power into a single cable (EtherCAT P), the BECKHOFF EPP1258-0002 reduces cabling complexity, lowers installation overhead, and minimizes the physical footprint required for decentralized I/O structures. It integrates Distributed Clocks technology, ensuring sub-microsecond synchronization with other devices on the EtherCAT network.

Features

  • Eight digital inputs (24 V DC) for collecting field sensor data
  • Two timestamp-enabled inputs (channels 0 and 1) with 1 ns resolution
  • Single-cable EtherCAT P technology integrating data and power (US/UP)
  • Standard M12 input connections and P-coded M8 bus interfaces
  • Integrated Distributed Clocks (DC) for precise system-wide synchronization
  • Protected design with IP65, IP66, and IP67 environmental protection ratings
  • Built-in sensor supply protection against short circuits

Applications

  • High-speed parts detection and registration mark sensing
  • Decentralized signal acquisition in packaging and assembly machines
  • Industrial robotics and automated handling systems
  • Precise event timing and edge detection in motion control setups

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Exact Model EPP1258-0002
Product Type EtherCAT P Box (Digital Input)
Number of Inputs 8 (2 with timestamping)
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter 10 us
Signal Voltage "0" -3 to +5 V (similar to EN 61131-2, type 3)
Signal Voltage "1" 11 to 30 V (similar to EN 61131-2, type 3)
Nominal Input Current typ. 3 mA (similar to EN 61131-2, type 3)
Distributed Clocks Yes
Timestamp Resolution 1 ns (channels 0 and 1)
Timestamp Precision 10 ns (+ input delay)
Sensor Supply From US (control voltage), max. 0.5 A total, short-circuit proof
Bus Interface 2 x M8 socket, shielded, screw type, P-coded (EtherCAT P)
Input Connection M12, 5-pin, A-coded
Current Consumption from US typ. 100 mA
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 165 g
Approvals CE, UL

Connections / Interfaces

Interface Function
M8 Sockets (P-coded) EtherCAT P input and output connection, transmitting both communication and supply voltage
M12 Sockets (5-pin, A-coded) Sensor input connections, supporting up to two channels per socket with integrated sensor supply

Installation Guidelines

  1. Ensure the system power supply is completely de-energized before mounting or wiring.
  2. Securely mount the EPP1258-0002 module to the machine frame using appropriate mounting screws.
  3. Connect the EtherCAT P cables to the P-coded M8 bus sockets. Hand-tighten and torque to specification to ensure IP65/66/67 sealing integrity.
  4. Attach the sensor cables to the M12 sockets, verifying proper pin alignment for the A-coded connectors.
  5. Ensure the total sensor current draw from the module does not exceed the rated 0.5 A limit.
  6. Scan the network within TwinCAT System Manager, import the device's ESI XML file if necessary, and map the corresponding process data.
Loading product navigation…

What is the main function of the BECKHOFF EPP1258-0002?

The BECKHOFF EPP1258-0002 is an EtherCAT P Box designed to collect eight 24 V DC digital signals from field-level sensors, with two of these inputs featuring high-precision timestamping functionality for accurate edge-detection applications.

Which channels on the BECKHOFF EPP1258-0002 support timestamping?

On the BECKHOFF EPP1258-0002, channels 0 and 1 support timestamping, providing a measurement resolution of 1 ns and sub-microsecond synchronization via Distributed Clocks.

What type of connection technology does the BECKHOFF EPP1258-0002 use?

The BECKHOFF EPP1258-0002 uses P-coded M8 sockets for its EtherCAT P bus communication and power connection, and 5-pin, A-coded M12 sockets for connecting field sensors.

Is the sensor supply on the BECKHOFF EPP1258-0002 protected against short circuits?

Yes, the BECKHOFF EPP1258-0002 supplies connected sensors with control voltage (US) up to a maximum total current of 0.5 A, and this sensor supply is fully short-circuit proof.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...