Beckhoff EPP2816-0008 EtherCAT P Box

Beckhoff EPP2816-0008 EtherCAT P Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPP2816-0008

  • Country of origin:Germany

  • Product Type: EtherCAT P Box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The EPP2816-0008 is a high-density EtherCAT P Box module designed for industrial automation, offering 16 digital outputs. Specifically engineered to streamline connectivity for multi-pin valve terminals, this module features a 25-pin D-sub output connection. It operates over the EtherCAT protocol, supporting distributed clocks for high-precision synchronization. The module is housed in an IP65/66/67-rated enclosure, making it ideal for decentralized installation in demanding, harsh industrial environments.

Features

  • 16 Digital Outputs via 25-pin D-sub connection
  • EtherCAT P protocol integration (combining communication and power)
  • Optimized for multi-pin connector valve terminals
  • Distributed clocks support for precise synchronization
  • Robust IP65/66/67 industrial protection
  • Short-circuit proof outputs (0.5 A per channel)
  • Wide operating temperature range: -25 degC to +60 degC

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Protocol EtherCAT P
Number of Outputs 16
Connection Type D-sub socket, 25-pin, UNC4-40
Max. Output Current 0.5 A per channel (∑ 3 A)
Nominal Voltage 24 V DC (-15 %/+20 %)
Bus Interface 2 x M8 socket, P-coded
Electrical Isolation 500 V
Dimensions Approx. 165 g
Protection Rating IP65/66/67
Approvals CE, UL

Installation Guidelines

  • Mounting: Designed for decentralized installation directly on machine frames. Ensure secure mounting using the provided mechanical housing features.
  • Connectivity: Connect the 25-pin D-sub cable to the valve terminal or actuator array. Ensure the UNC4-40 screws are fully tightened to maintain environmental integrity.
  • Bus Connection: Utilize the P-coded M8 connectors for EtherCAT P bus communication and power supply feeding.
  • Power Management: Ensure the total load current (∑) does not exceed 3 A, and monitor the 0.5 A per-channel limit.
  • Environment: The module is rated for -25 degC to +60 degC. Ensure cables are strain-relieved and routed to avoid pinch points.

What is the output capacity of the EPP2816-0008?

This module provides 16 digital outputs with a capacity of 0.5 A per channel (3 A total sum current).

What is the primary application for this module?

The EPP2816-0008 is specifically optimized for multi-pin connector valve terminals.

Does this module support distributed clocks?

Yes, it supports distributed clocks for synchronized control.

What is the environmental protection rating?

The module is IP65/66/67 rated, suitable for harsh, decentralized industrial use.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...