BECKHOFF

BECKHOFF ERI1809-0021 IO-Link Digital Input Box

SKU ERI1809-0021

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: ERI1809-0021
  • Origin Germany
  • Product Type: IO-Link Modules
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 60 mm x 126 mm x 26.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF ERI1809-0021 is an IP67-rated IO-Link box designed to acquire 16 digital input signals in decentralized field environments. Constructed with a highly durable zinc die-cast housing, this module is optimized for direct installation on machines and equipment, eliminating the need for protective control cabinets.

Operating under the IO-Link Specification V1.1 (Class A), the module provides high-speed COM3 transmission rates up to 230.4 kbaud. Standard A-coded M12 connections handle communication and power, while 16 M8 screw-type connection points accommodate sensor inputs. Integrated short-circuit protection and configurable input filters ensure reliable signal collection under demanding industrial conditions.

Features

  • 16 digital input channels via compact M8 screw-type connection points.
  • Supports IO-Link Specification V1.1 (Class A) interface.
  • Fast COM3 data transfer rate (230.4 kbaud) for real-time monitoring.
  • Heavy-duty zinc die-cast housing for rugged mechanical protection.
  • High-level ingress protection with IP65, IP66, and IP67 ratings.
  • Adjustable input filter times (0 to 20 ms) to optimize signal stability.
  • Short-circuit proof sensor supply from L+ up to 0.5 A total.

Applications

  • Decentralized input monitoring on machine frames and conveyor lines.
  • Control-cabinet-free sensor integration in wet or dusty processing plants.
  • Automated assembly and material handling systems using IO-Link architectures.
  • Connection of standard proximity switches and mechanical limit switches.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model ERI1809-0021
Housing Material Zinc die-cast
Dimensions (W x H x D) 60 mm x 126 mm x 26.5 mm
Weight approx. 450 g

Signal and I/O

Parameter Specification
Number of Inputs 16
Input Connections M8, screw type
Input Filter Time 3.0 ms (default), adjustable 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)

Electrical

Parameter Specification
Nominal Input Voltage 24 V DC (-15% / +20%)
Sensor Supply max. 0.5 A from L+, short-circuit proof in total
Current Consumption typ. 100 mA from L+

IO-Link and Communication

Parameter Specification
Interface 1 x M12 plug, A-coded
IO-Link Version Specification V1.1, Class A
Data Transfer Rate 230.4 kbaud (COM 3)

Environmental

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Approvals

Parameter Specification
Approvals and Markings CE, UL

Installation Guidelines

  1. Verify that the local power supply is de-energized and corresponds to the nominal input voltage range of 24 V DC prior to physical installation.
  2. Mount the zinc die-cast housing securely to the machinery frame using either the two 3.5 mm diameter fixing holes for M3 screws, or the two 4.5 mm diameter fixing holes for M4 screws.
  3. Connect the digital sensor cables to the 16 M8 screw-type connection points. Thread and tighten all plugs appropriately to maintain the IP65/66/67 rating.
  4. Ensure any unused M8 or M12 connections are sealed with appropriate protective caps to prevent dust or moisture ingress.
  5. Connect the IO-Link communication cable to the A-coded M12 interface plug on the module.
  6. Re-energize the system, configure parameters via your IO-Link master, and verify input operation through the diagnostic system.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF ERI1809-0021?
The BECKHOFF ERI1809-0021 is a decentralized field-mountable IO-Link box that collects up to 16 digital sensor inputs and transmits them to an IO-Link master using COM3 speed.
What connection technology is used for sensor inputs on the BECKHOFF ERI1809-0021?
The BECKHOFF ERI1809-0021 features 16 M8 screw-type connectors to secure digital inputs directly in the field.
What are the environment protection ratings for this module?
The BECKHOFF ERI1809-0021 conforms to EN 60529 and provides IP65, IP66, and IP67 ratings, making it dust-tight and resistant to water jets and temporary immersion when connectors are sealed.
What housing material is the BECKHOFF ERI1809-0021 made from?
The BECKHOFF ERI1809-0021 is housed in a robust zinc die-cast enclosure, engineered for severe mechanical stress in industrial environments.
Does the BECKHOFF ERI1809-0021 feature adjustable input filtering?
Yes, the BECKHOFF ERI1809-0021 has a default input filter time of 3.0 ms, which can be adjusted anywhere from 0 to 20 ms to suit the input application.
Reviews

ERI1809-0021

Stock & lead time on request

Call
1 of 1

BECKHOFF ERI1809-0021 IO-Link Digital Input Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ERI1809-0021

  • Country of origin:Germany

  • Product Type: IO-Link Modules

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 60 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF ERI1809-0021 is an IP67-rated IO-Link box designed to acquire 16 digital input signals in decentralized field environments. Constructed with a highly durable zinc die-cast housing, this module is optimized for direct installation on machines and equipment, eliminating the need for protective control cabinets.

Operating under the IO-Link Specification V1.1 (Class A), the module provides high-speed COM3 transmission rates up to 230.4 kbaud. Standard A-coded M12 connections handle communication and power, while 16 M8 screw-type connection points accommodate sensor inputs. Integrated short-circuit protection and configurable input filters ensure reliable signal collection under demanding industrial conditions.

Features

  • 16 digital input channels via compact M8 screw-type connection points.
  • Supports IO-Link Specification V1.1 (Class A) interface.
  • Fast COM3 data transfer rate (230.4 kbaud) for real-time monitoring.
  • Heavy-duty zinc die-cast housing for rugged mechanical protection.
  • High-level ingress protection with IP65, IP66, and IP67 ratings.
  • Adjustable input filter times (0 to 20 ms) to optimize signal stability.
  • Short-circuit proof sensor supply from L+ up to 0.5 A total.

Applications

  • Decentralized input monitoring on machine frames and conveyor lines.
  • Control-cabinet-free sensor integration in wet or dusty processing plants.
  • Automated assembly and material handling systems using IO-Link architectures.
  • Connection of standard proximity switches and mechanical limit switches.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model ERI1809-0021
Housing Material Zinc die-cast
Dimensions (W x H x D) 60 mm x 126 mm x 26.5 mm
Weight approx. 450 g

Signal and I/O

Parameter Specification
Number of Inputs 16
Input Connections M8, screw type
Input Filter Time 3.0 ms (default), adjustable 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)

Electrical

Parameter Specification
Nominal Input Voltage 24 V DC (-15% / +20%)
Sensor Supply max. 0.5 A from L+, short-circuit proof in total
Current Consumption typ. 100 mA from L+

IO-Link and Communication

Parameter Specification
Interface 1 x M12 plug, A-coded
IO-Link Version Specification V1.1, Class A
Data Transfer Rate 230.4 kbaud (COM 3)

Environmental

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Approvals

Parameter Specification
Approvals and Markings CE, UL

Installation Guidelines

  1. Verify that the local power supply is de-energized and corresponds to the nominal input voltage range of 24 V DC prior to physical installation.
  2. Mount the zinc die-cast housing securely to the machinery frame using either the two 3.5 mm diameter fixing holes for M3 screws, or the two 4.5 mm diameter fixing holes for M4 screws.
  3. Connect the digital sensor cables to the 16 M8 screw-type connection points. Thread and tighten all plugs appropriately to maintain the IP65/66/67 rating.
  4. Ensure any unused M8 or M12 connections are sealed with appropriate protective caps to prevent dust or moisture ingress.
  5. Connect the IO-Link communication cable to the A-coded M12 interface plug on the module.
  6. Re-energize the system, configure parameters via your IO-Link master, and verify input operation through the diagnostic system.
Loading product navigation…

What is the primary function of the BECKHOFF ERI1809-0021?

The BECKHOFF ERI1809-0021 is a decentralized field-mountable IO-Link box that collects up to 16 digital sensor inputs and transmits them to an IO-Link master using COM3 speed.

What connection technology is used for sensor inputs on the BECKHOFF ERI1809-0021?

The BECKHOFF ERI1809-0021 features 16 M8 screw-type connectors to secure digital inputs directly in the field.

What are the environment protection ratings for this module?

The BECKHOFF ERI1809-0021 conforms to EN 60529 and provides IP65, IP66, and IP67 ratings, making it dust-tight and resistant to water jets and temporary immersion when connectors are sealed.

What housing material is the BECKHOFF ERI1809-0021 made from?

The BECKHOFF ERI1809-0021 is housed in a robust zinc die-cast enclosure, engineered for severe mechanical stress in industrial environments.

Does the BECKHOFF ERI1809-0021 feature adjustable input filtering?

Yes, the BECKHOFF ERI1809-0021 has a default input filter time of 3.0 ms, which can be adjusted anywhere from 0 to 20 ms to suit the input application.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...