1 of 1

Beckhoff IL2300-C310 Fieldbus Box PLC Box

Beckhoff IL2300-C310 Fieldbus Box PLC Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IL2300-C310

  • Country of origin:Germany

  • Product Type: PLC Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Decentralized signal routing in demanding automated environments is managed directly at the machine level by the Beckhoff IL2300-C310, a rugged PROFIBUS DP fieldbus PLC Box. Engineered to bypass the need for protective control cabinets, this module features a highly resilient IP67 housing and handles communications using standard physical media profiles. Crucial system setups and configuration modifications are achieved easily using the KS2000 software utility or directly via control-level parameters. It supports DP-V1 extensions for enhanced diagnostics, making it an efficient choice for complex topology architectures requiring distributed industrial intelligence.

Features

  • Automatic Baud Rate Detection: Detects and locks onto incoming bus transfer rates automatically up to 12 Mbaud.
  • DP-V1 Extension Support: Allows acyclic data transfer for advanced configuration, parameterization, and diagnostic feedback.
  • Robust Environmental Hardening: Rated for IP65, IP66, and IP67 industrial environments, protecting against dust ingress and high-pressure water jets.
  • Compact Standardized Footprint: Designed for direct machine frame mounting, minimizing cable runs and panel space.
  • Standardized Connector Layout: Utilizes standard M12 and M8 circular industrial connectors to simplify replacement and installation cycles.

Applications

  • Automated manufacturing and robotic assembly lines requiring distributed node architectures.
  • Packaging machineries, high-vibration systems, and materials handling conveyors.
  • Wet areas and washdown environments such as food processing facilities or chemical dosing systems.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Identifier IL2300-C310
Bus Interface 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Options Via KS2000 configuration software or PLC controller
Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type specification
Internal Current Draw (Box) 85 mA + current consumption of sensors (max. 0.5 A)
Power Feed Connection 1 x M8 male connector, 4-pin
Power Downstream Link 1 x M8 female socket, 4-pin
Electrical Isolation Control voltage/fieldbus: none; Control/Inputs or Outputs: By I/O type
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Ingress Protection Rating IP65/66/67 (conforms to EN 60529)
Shock and Vibration Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Standards Conforms to EN 61000-6-2 / EN 61000-6-4
Certifications CE, UL
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Type Pin Count / Coding Standard Purpose
Bus Interface (In/Out) 5-pin, B-coded M12 socket Primary PROFIBUS DP network connection segment
Power Feed Input 4-pin, M8 male plug Incoming 24 V DC control voltage and logic feed
Power Link Output 4-pin, M8 female socket Downstream daisy-chain distribution of 24 V DC system power

Empirical Engineering Insights

Alternative Models & Compatibility

When integrating the IL2300-C310 into older system architectures, ensure that your master GSD database matches the hardware revision of the box. Although it serves as a direct drop-in functional unit for legacy decentralized PROFIBUS modules, check software support within TwinCAT 2.x or 3.x configuration profiles to guarantee appropriate addressing offsets for complex I/O topologies.

Application Pitfalls & Engineering Notes

Keep in mind that while the module carries robust sealing specs (IP67), local heat accumulation inside dense non-ventilated mounting locations can shorten the operational lifespan of the unit. Ensure adjacent heat-producing equipment is sufficiently spaced. Avoid exceeding the maximum sensor pass-through current of 0.5 A; attempting to power multiple heavy-duty sensors off a single branch daisy-chained feed will trigger overcurrent conditions.

Commissioning & Wiring Tips

Always use high-quality, pre-assembled M12 PROFIBUS cables to prevent impedance mismatch at high Mbaud rates. If the communication interface behaves erratically, check for proper termination. Active termination should be used at both physical ends of the PROFIBUS network segment. Torque M8 and M12 connectors properly to keep moisture out of unused pins.

Installation Guidelines

CRITICAL WARNING: Disconnect all electrical feeds before carrying out any mounting or termination procedures. Ensure control lines and load power sources are locked out to prevent accidental power-up. Wait for stored electrostatic charges in downstream line capacitors to dissipate fully before handling wiring harnesses.
1
Mount the IL2300-C310 physically to a flat, rigid substrate using standard M4 screws. Avoid applying excessive structural tension to the plastic casing.
2
Connect the 5-pin, B-coded M12 PROFIBUS input line to the designated interface, ensuring the pins align smoothly before tightening the knurled collar.
3
Attach the M8 24 V DC power feed cable. Screw downstream power linkages securely into place, and cover any empty ports with protective dust caps.

What is the maximum pass-through sensor current supported by the IL2300-C310?

The internal control electronics draw 85 mA, and the maximum pass-through current available for connected sensors is strictly limited to 0.5 A.

How does the module handle communication speed configuration?

It features integrated automatic baud rate detection, which matches and locks onto the controller's PROFIBUS DP clock rate up to 12 Mbaud.

What software is used to configure the IL2300-C310?

Configuration, parameter changes, and diagnostic profiles can be completed using the Beckhoff KS2000 utility or directly from the master PLC controller.

Does this model have integrated active PROFIBUS line termination?

No, it does not feature built-in active termination. External termination resistors or modules must be used at the end of physical PROFIBUS runs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.