Description

The BECKHOFF IP2001-B200 is an industrial Fieldbus Box module designed to interface digital control commands with decentralized field actuators. Operating as an 8-channel digital output unit, this device allows direct, local deployment of I/O processing on machinery, significantly reducing cabling requirements inside central control enclosures.

Equipped with a Lightbus communication interface, this Fieldbus Box utilizes fiber optic technology to ensure high-speed data transmission and absolute resistance to electromagnetic interference (EMI). Its compact housing and resilient mechanical design make it suitable for installation directly within challenging operational environments.

Features

  • 8 digital output channels for controlling external loads.
  • Lightbus system connection via high-noise-immunity fiber optic lines.
  • M8 round screw-style connector interface for compact and secure field connections.
  • Robust housing designed for decentralized, cabinet-free mounting layouts.
  • Clear channel status indication for simplified diagnostic and commissioning activities.

Applications

  • Decentralized control of binary actuators, valves, indicators, and small contactors.
  • Automated assembly systems requiring distributed physical I/O hubs.
  • Applications in environments with high electromagnetic disturbance where fiber optic communication is required.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP2001-B200
Product Type Fieldbus Box

Signal and Electrical

Parameter Specification
Number of Channels 8 digital outputs
Nominal Voltage 24 V DC
Maximum Output Current 0.5 A per channel

Communication and Connection

Parameter Specification
Fieldbus Interface Lightbus
I/O Connection Technology M8 screw connectors

Installation Guidelines

  1. Ensure that all power sources to the system and associated machinery are fully disconnected prior to mounting.
  2. Mount the Fieldbus Box securely to a flat, rigid surface using appropriate mounting hardware to minimize mechanical vibration.
  3. Connect the Lightbus fiber optic cables, ensuring that connector faces are clean and free of dust to prevent signal loss.
  4. Wire the 24 V DC load outputs using matching M8 cables, adhering strictly to current limits per channel.
  5. Apply control power and verify system diagnostics via the diagnostic LEDs on the module interface.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2001-B200?
The BECKHOFF IP2001-B200 is an 8-channel digital output Fieldbus Box module that routes binary commands from a Lightbus fiber optic network to decentralized field actuators operating at 24 V DC.
What connector type is utilized on the BECKHOFF IP2001-B200 for outputs?
The BECKHOFF IP2001-B200 features space-saving M8 round screw connectors to establish secure and dust-resistant electrical connections with actuators in the field.
What is the maximum output current rating for each channel on the BECKHOFF IP2001-B200?
The BECKHOFF IP2001-B200 supports a maximum load current of 0.5 A per digital output channel, suitable for typical binary loads like small solenoid valves or indicators.
Which communication system is compatible with the BECKHOFF IP2001-B200?
The BECKHOFF IP2001-B200 is built specifically to integrate with Beckhoff Lightbus networks, employing fiber optic cables for high transmission rates and reliable noise immunity.
Reviews

IP2001-B200

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2001-B200 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2001-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2001-B200 is an industrial Fieldbus Box module designed to interface digital control commands with decentralized field actuators. Operating as an 8-channel digital output unit, this device allows direct, local deployment of I/O processing on machinery, significantly reducing cabling requirements inside central control enclosures.

Equipped with a Lightbus communication interface, this Fieldbus Box utilizes fiber optic technology to ensure high-speed data transmission and absolute resistance to electromagnetic interference (EMI). Its compact housing and resilient mechanical design make it suitable for installation directly within challenging operational environments.

Features

  • 8 digital output channels for controlling external loads.
  • Lightbus system connection via high-noise-immunity fiber optic lines.
  • M8 round screw-style connector interface for compact and secure field connections.
  • Robust housing designed for decentralized, cabinet-free mounting layouts.
  • Clear channel status indication for simplified diagnostic and commissioning activities.

Applications

  • Decentralized control of binary actuators, valves, indicators, and small contactors.
  • Automated assembly systems requiring distributed physical I/O hubs.
  • Applications in environments with high electromagnetic disturbance where fiber optic communication is required.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP2001-B200
Product Type Fieldbus Box

Signal and Electrical

Parameter Specification
Number of Channels 8 digital outputs
Nominal Voltage 24 V DC
Maximum Output Current 0.5 A per channel

Communication and Connection

Parameter Specification
Fieldbus Interface Lightbus
I/O Connection Technology M8 screw connectors

Installation Guidelines

  1. Ensure that all power sources to the system and associated machinery are fully disconnected prior to mounting.
  2. Mount the Fieldbus Box securely to a flat, rigid surface using appropriate mounting hardware to minimize mechanical vibration.
  3. Connect the Lightbus fiber optic cables, ensuring that connector faces are clean and free of dust to prevent signal loss.
  4. Wire the 24 V DC load outputs using matching M8 cables, adhering strictly to current limits per channel.
  5. Apply control power and verify system diagnostics via the diagnostic LEDs on the module interface.
Loading product navigation…

What is the primary function of the BECKHOFF IP2001-B200?

The BECKHOFF IP2001-B200 is an 8-channel digital output Fieldbus Box module that routes binary commands from a Lightbus fiber optic network to decentralized field actuators operating at 24 V DC.

What connector type is utilized on the BECKHOFF IP2001-B200 for outputs?

The BECKHOFF IP2001-B200 features space-saving M8 round screw connectors to establish secure and dust-resistant electrical connections with actuators in the field.

What is the maximum output current rating for each channel on the BECKHOFF IP2001-B200?

The BECKHOFF IP2001-B200 supports a maximum load current of 0.5 A per digital output channel, suitable for typical binary loads like small solenoid valves or indicators.

Which communication system is compatible with the BECKHOFF IP2001-B200?

The BECKHOFF IP2001-B200 is built specifically to integrate with Beckhoff Lightbus networks, employing fiber optic cables for high transmission rates and reliable noise immunity.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...