Description

The BECKHOFF IP2002-B810 is a decentralized Fieldbus Box designed to extend industrial control architectures directly into demanding field environments. Equipped with an integrated RS232 serial interface and eight digital output channels, this module acts as a robust point-to-point communication and control node. It enables direct interfacing between control computers, industrial PCs, or serial controllers and field-level actuators without requiring intermediate cabinets.

Operating on a 24 V DC auxiliary and control supply, the BECKHOFF IP2002-B810 distributes control signals efficiently across its eight digital channels. Designed for extreme durability, the standard polyamide housing offers outstanding resistance to moisture, dust, and mechanical stress, making it an excellent choice for distributed installations in modern automated production lines, material handling systems, and assembly machinery.

The module facilitates straightforward integration via a standard RS232 connection with support for multiple baud rates, providing highly configurable serial communications through standard software tools. Standardized M12 and M8 connections secure reliable physical wiring for fieldbus signals, control power, and digital outputs.

Features

  • Eight independent digital output channels rated at 0.5 A per channel.
  • Integrated RS232 communication interface supporting baud rates up to 38.4 kbaud.
  • Direct machine mounting capability with high IP65, IP66, and IP67 ingress ratings.
  • Short-circuit-proof digital outputs with integrated overload diagnostics.
  • Polyamide (PA6) housing construction offering reliable physical protection in harsh environments.
  • Standardized M12 connection technology for fieldbus interface and output signals.
  • M8 feed and downstream connectors for simplified power routing.

Applications

  • Decentralized control of solenoids, contactors, indicators, and small actuators.
  • Direct machine-level integration bypassing traditional electrical enclosures.
  • Point-to-point serial communication links in automated production systems.
  • Material handling, conveying, and sorting equipment installations.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2002-B810
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Weight Approx. 210 g
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius

Digital Outputs

Parameter Specification
Number of Outputs 8
Output Connection Type M12, screw type
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Load Types Ohmic, inductive, lamp load
Short-Circuit Current Typ. 1.5 A
Process Image Bit Width 8 outputs

RS232 and Communication

Parameter Specification
Fieldbus Interface RS232 (IPxxxx-B810, IL230x-B810)
Physical Connection 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates 9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)
Data Transfer Medium Shielded copper cable, 2 x 0.25 mm²
Configuration Software Via KS2000 serial interface software

Electrical and Power Supply

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Current Consumption (Box) 45 mA + sensor current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: Yes

Connections / Interfaces

Interface or Terminal Function
M12 Socket (5-pin, B-coded) RS232 communication interface connection
M8 Male Connector (4-pin) Feed-in socket for 24 V DC control and auxiliary power supply
M8 Female Connector (4-pin) Downstream loop-through power supply for neighboring modules
M12 Screw Connectors 8 digital output channel connections for actuator wiring

Installation Guidelines

  1. Ensure the entire industrial automation system is safely powered down and locked out before starting the installation process.
  2. Mount the module on a flat, vibration-resistant surface utilizing the two integrated 3.5 mm mounting holes with suitable M3 hardware.
  3. Verify that the incoming control voltage supply matches the rated 24 V DC specification prior to routing connections.
  4. Connect the incoming 24 V DC supply to the 4-pin M8 male feed connector and loop to adjacent modules from the M8 female socket if necessary.
  5. Verify correct alignment and orientation of all M12 and M8 screw connectors. Tighten to specification to preserve the IP65/66/67 environmental seal.
  6. Seal any unused M12 and M8 ports with verified protective caps to prevent dust, water, and debris ingress.
  7. Apply control power, check the status of system indicators, and establish communications via the RS232 interface.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2002-B810?
The BECKHOFF IP2002-B810 is an IP67-rated Fieldbus Box designed to connect up to eight digital outputs to a host controller or industrial PC over an integrated RS232 serial interface.
What is the maximum current capacity per output channel on the BECKHOFF IP2002-B810?
Each of the eight digital output channels on the BECKHOFF IP2002-B810 can source a maximum load current of 0.5 A at 24 V DC, and each channel is individually protected against short circuits.
What physical protection ratings does the BECKHOFF IP2002-B810 housing offer?
The BECKHOFF IP2002-B810 features a robust polyamide housing certified to IP65, IP66, and IP67 protection classes, allowing direct mounting on machinery in dusty, wet, or harsh industrial environments.
How is power supplied and distributed to the BECKHOFF IP2002-B810?
Power for the BECKHOFF IP2002-B810 is supplied via a 4-pin M8 male connector, and it can be looped through to downstream modules using the matching 4-pin M8 female downstream connector.
What baud rates does the serial interface on the BECKHOFF IP2002-B810 support?
The BECKHOFF IP2002-B810 supports RS232 serial communication speeds of 9.6 kbaud, 19.2 kbaud, and a default rate of 38.4 kbaud.
Reviews

IP2002-B810

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2002-B810 Fieldbus Box 8-Channel Digital Output RS232

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2002-B810

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 210g

  • Dimensions: 30 mm x 175 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2002-B810 is a decentralized Fieldbus Box designed to extend industrial control architectures directly into demanding field environments. Equipped with an integrated RS232 serial interface and eight digital output channels, this module acts as a robust point-to-point communication and control node. It enables direct interfacing between control computers, industrial PCs, or serial controllers and field-level actuators without requiring intermediate cabinets.

Operating on a 24 V DC auxiliary and control supply, the BECKHOFF IP2002-B810 distributes control signals efficiently across its eight digital channels. Designed for extreme durability, the standard polyamide housing offers outstanding resistance to moisture, dust, and mechanical stress, making it an excellent choice for distributed installations in modern automated production lines, material handling systems, and assembly machinery.

The module facilitates straightforward integration via a standard RS232 connection with support for multiple baud rates, providing highly configurable serial communications through standard software tools. Standardized M12 and M8 connections secure reliable physical wiring for fieldbus signals, control power, and digital outputs.

Features

  • Eight independent digital output channels rated at 0.5 A per channel.
  • Integrated RS232 communication interface supporting baud rates up to 38.4 kbaud.
  • Direct machine mounting capability with high IP65, IP66, and IP67 ingress ratings.
  • Short-circuit-proof digital outputs with integrated overload diagnostics.
  • Polyamide (PA6) housing construction offering reliable physical protection in harsh environments.
  • Standardized M12 connection technology for fieldbus interface and output signals.
  • M8 feed and downstream connectors for simplified power routing.

Applications

  • Decentralized control of solenoids, contactors, indicators, and small actuators.
  • Direct machine-level integration bypassing traditional electrical enclosures.
  • Point-to-point serial communication links in automated production systems.
  • Material handling, conveying, and sorting equipment installations.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2002-B810
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Weight Approx. 210 g
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius

Digital Outputs

Parameter Specification
Number of Outputs 8
Output Connection Type M12, screw type
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Load Types Ohmic, inductive, lamp load
Short-Circuit Current Typ. 1.5 A
Process Image Bit Width 8 outputs

RS232 and Communication

Parameter Specification
Fieldbus Interface RS232 (IPxxxx-B810, IL230x-B810)
Physical Connection 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates 9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)
Data Transfer Medium Shielded copper cable, 2 x 0.25 mm²
Configuration Software Via KS2000 serial interface software

Electrical and Power Supply

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Current Consumption (Box) 45 mA + sensor current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: Yes

Connections / Interfaces

Interface or Terminal Function
M12 Socket (5-pin, B-coded) RS232 communication interface connection
M8 Male Connector (4-pin) Feed-in socket for 24 V DC control and auxiliary power supply
M8 Female Connector (4-pin) Downstream loop-through power supply for neighboring modules
M12 Screw Connectors 8 digital output channel connections for actuator wiring

Installation Guidelines

  1. Ensure the entire industrial automation system is safely powered down and locked out before starting the installation process.
  2. Mount the module on a flat, vibration-resistant surface utilizing the two integrated 3.5 mm mounting holes with suitable M3 hardware.
  3. Verify that the incoming control voltage supply matches the rated 24 V DC specification prior to routing connections.
  4. Connect the incoming 24 V DC supply to the 4-pin M8 male feed connector and loop to adjacent modules from the M8 female socket if necessary.
  5. Verify correct alignment and orientation of all M12 and M8 screw connectors. Tighten to specification to preserve the IP65/66/67 environmental seal.
  6. Seal any unused M12 and M8 ports with verified protective caps to prevent dust, water, and debris ingress.
  7. Apply control power, check the status of system indicators, and establish communications via the RS232 interface.
Loading product navigation…

What is the primary function of the BECKHOFF IP2002-B810?

The BECKHOFF IP2002-B810 is an IP67-rated Fieldbus Box designed to connect up to eight digital outputs to a host controller or industrial PC over an integrated RS232 serial interface.

What is the maximum current capacity per output channel on the BECKHOFF IP2002-B810?

Each of the eight digital output channels on the BECKHOFF IP2002-B810 can source a maximum load current of 0.5 A at 24 V DC, and each channel is individually protected against short circuits.

What physical protection ratings does the BECKHOFF IP2002-B810 housing offer?

The BECKHOFF IP2002-B810 features a robust polyamide housing certified to IP65, IP66, and IP67 protection classes, allowing direct mounting on machinery in dusty, wet, or harsh industrial environments.

How is power supplied and distributed to the BECKHOFF IP2002-B810?

Power for the BECKHOFF IP2002-B810 is supplied via a 4-pin M8 male connector, and it can be looped through to downstream modules using the matching 4-pin M8 female downstream connector.

What baud rates does the serial interface on the BECKHOFF IP2002-B810 support?

The BECKHOFF IP2002-B810 supports RS232 serial communication speeds of 9.6 kbaud, 19.2 kbaud, and a default rate of 38.4 kbaud.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...