Description
Designed for decentralized installation directly in harsh industrial environments, the Beckhoff IP2040-B200 digital output module establishes reliable connections between control networks and field-level actuators. This Lightbus Fieldbus Box features 8 digital outputs capable of switching loads up to 2 A per channel, with a cumulative module current of up to 12 A. By operating on the high-speed Lightbus fiber-optic ring system, the unit ensures high noise immunity and fast signal transmission over long distances.
The module is housed in a compact, rugged PA6 polyamide enclosure with an IP65/66/67 protection rating, allowing direct machine mounting without an electrical enclosure. This reduces wiring overhead, simplifies diagnostics, and optimizes space within decentralized automation systems. Connections to the actuators are established via secure 8 mm snap-type connectors, providing robust mechanical stability against shock and vibration.
Features
- 8-channel digital output configuration (24 V DC)
- Lightbus fiber-optic system interface with 2.5 Mbaud transmission rate
- 2 A maximum load current per channel (individually short-circuit proof)
- High cumulative current limit of up to 12 A
- Direct machine mounting with IP65/66/67 rated environmental protection
- Fibre-optic physical layer provides immunity to electromagnetic interference (EMI)
- Comprehensive diagnostics and configuration capabilities via KS2000 or the master controller
Applications
- Decentralized machine control and factory automation
- Material handling and conveyor systems
- Assembly lines and packaging machinery
- Environments with severe electromagnetic interference (EMI)
Technical Specifications
| Manufacturer |
Beckhoff |
| Model / Part Number |
IP2040-B200 |
| Product Type |
Fieldbus Box Module |
| Fieldbus Protocol |
Lightbus |
| Number of Outputs |
8 |
| Output Connections |
8 mm, snap-type |
| Nominal Output Voltage |
24 V DC (-15 % / +20 %) |
| Max. Output Current |
2 A per channel (individually short-circuit proof) |
| Total Module Current |
Max. 12 A (channel 0 to 3: max 4 A, 4 to 5: max 4 A, 6 to 7: max 4 A) |
| Load Types Supported |
Ohmic, inductive, lamp load |
| Data Transfer Rate |
2.5 Mbaud |
| Bus Interface |
2 x fiber-optic socket for plug ZS1020-0010 |
| Data Transfer Medium |
APF (plastic) fiber-optic conductor (1,000 micrometers) |
| Power Supply Connection |
2 x M8 male socket, 4-pin (feed only, no downstream connection) |
| Electrical Isolation |
Control voltage to fieldbus: Yes |
| Enclosure Material |
PA6 (Polyamide) |
| Protection Rating |
IP65, IP66, IP67 (conforms to EN 60529) |
| Operating Temperature |
0 to +55 degC |
| Storage Temperature |
-25 to +85 degC |
| Vibration / Shock Resistance |
Conforms to EN 60068-2-6 / EN 60068-2-27 |
| Dimensions (W x H x D) |
30 mm x 210 mm x 26.5 mm |
| Weight |
Approx. 250 g |
Connections and Interfaces
| Connection Point |
Type / Specification |
Function |
| Bus In / Bus Out |
2 x Fiber-optic socket |
Lightbus communication ring connection |
| Power Feed |
2 x M8 male socket, 4-pin |
24 V DC control and load voltage input |
| Outputs 0 to 7 |
8 mm snap-type sockets |
Actuator signal connection |
Installation Guidelines
- Mount the module directly onto flat surfaces using 2 fixing holes suitable for M3 screws.
- Ensure that the minimum bending radius of the APF plastic fiber-optic cables is maintained during routing to prevent signal attenuation.
- Always cover unused M8 and 8 mm sockets with IP67 protective caps to preserve the environmental seal.
- Avoid installing the module in areas subject to continuous fluid pooling or direct high-pressure spray.
Compliance and Certifications
- CE
- UL
- EMC Immunity/Emission: EN 61000-6-2 / EN 61000-6-4