BECKHOFF

BECKHOFF IP2302-B528 Fieldbus Box

SKU IP2302-B528

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP2302-B528
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP2302-B528 is an industrial IP67-rated Fieldbus Box designed for decentralised machine-level acquisition of digital signals. This compact, robust module integrates four digital inputs and four digital outputs into a single device, enabling direct processing of local signals in harsh industrial environments outside of traditional control cabinets.

Operating as a node on a DeviceNet network, the BECKHOFF IP2302-B528 features an integrated M12 T-connector to facilitate straightforward line-topology network installations. By positioning the I/O interface closer to physical sensors and actuators, this Fieldbus Box significantly reduces wiring complexity, material overhead, and installation labor.

Features

  • Four digital inputs (24 V DC) with a 3 ms input filter for signal stability
  • Four digital outputs (24 V DC) supporting up to 0.5 A load current per channel
  • DeviceNet network interface equipped with an integrated M12 T-connector for direct loop-through wiring
  • M12 connection technology for secure, vibration-resistant sensor and actuator cabling
  • IP67-rated housing, providing high protection against dust, moisture, and water ingress
  • Integrated status and diagnostics LEDs indicating network health, power, and I/O states

Applications

  • Decentralized assembly and packaging systems
  • Conveyor systems and material handling machinery
  • Pneumatic valve manifold control and integration
  • Machine tool and processing line decentralized I/O structures

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2302-B528
Product Type Fieldbus Box (Digital Input/Output)
Fieldbus Protocol DeviceNet
Number of Inputs 4
Input Voltage 24 V DC
Input Filter Time 3 ms
Number of Outputs 4
Output Voltage 24 V DC
Max. Output Current 0.5 A per channel
Connection Method M12 screw connectors
IP Rating IP67
Operating Temperature 0 degC to +55 degC

Connections / Interfaces

Interface or Terminal Function
DeviceNet (M12) Network communication with integrated T-connector loop-through
I/O Sockets (M12) Connection of 4-channel digital inputs and 4-channel digital outputs
Power Supply (M8) Control voltage and load voltage distribution

Installation Guidelines

  1. Verify that the incoming power supplies are fully de-energized before mounting.
  2. Securely mount the housing of the Fieldbus Box to a flat, vibration-free surface using the designated mounting holes.
  3. Connect the DeviceNet network cables to the integrated M12 T-connector interface, ensuring correct alignment.
  4. Plug the digital sensor and actuator lines into the correct M12 signal sockets.
  5. Tighten all M12 and M8 collars to the recommended torque specifications to preserve the unit's IP67 water and dust ingress rating.
  6. Apply system power and verify channel function and network state using the onboard diagnostics LEDs.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2302-B528?
The BECKHOFF IP2302-B528 is an IP67-rated Fieldbus Box designed to acquire four digital input signals and control four digital outputs via a DeviceNet network interface.
What connector standard does the BECKHOFF IP2302-B528 use for field devices?
The BECKHOFF IP2302-B528 features standard industrial M12 screw connectors for secure, moisture-resistant sensor, actuator, and network wiring.
Does the BECKHOFF IP2302-B528 require a separate network T-connector?
No, the BECKHOFF IP2302-B528 includes an integrated DeviceNet T-connector on the housing, allowing direct daisy-chain connection of network lines without external splitters.
What is the electrical load capacity for the outputs on the BECKHOFF IP2302-B528?
The BECKHOFF IP2302-B528 supports up to 0.5 A per output channel, operating on a nominal 24 V DC supply.
Reviews

IP2302-B528

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2302-B528 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2302-B528

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2302-B528 is an industrial IP67-rated Fieldbus Box designed for decentralised machine-level acquisition of digital signals. This compact, robust module integrates four digital inputs and four digital outputs into a single device, enabling direct processing of local signals in harsh industrial environments outside of traditional control cabinets.

Operating as a node on a DeviceNet network, the BECKHOFF IP2302-B528 features an integrated M12 T-connector to facilitate straightforward line-topology network installations. By positioning the I/O interface closer to physical sensors and actuators, this Fieldbus Box significantly reduces wiring complexity, material overhead, and installation labor.

Features

  • Four digital inputs (24 V DC) with a 3 ms input filter for signal stability
  • Four digital outputs (24 V DC) supporting up to 0.5 A load current per channel
  • DeviceNet network interface equipped with an integrated M12 T-connector for direct loop-through wiring
  • M12 connection technology for secure, vibration-resistant sensor and actuator cabling
  • IP67-rated housing, providing high protection against dust, moisture, and water ingress
  • Integrated status and diagnostics LEDs indicating network health, power, and I/O states

Applications

  • Decentralized assembly and packaging systems
  • Conveyor systems and material handling machinery
  • Pneumatic valve manifold control and integration
  • Machine tool and processing line decentralized I/O structures

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2302-B528
Product Type Fieldbus Box (Digital Input/Output)
Fieldbus Protocol DeviceNet
Number of Inputs 4
Input Voltage 24 V DC
Input Filter Time 3 ms
Number of Outputs 4
Output Voltage 24 V DC
Max. Output Current 0.5 A per channel
Connection Method M12 screw connectors
IP Rating IP67
Operating Temperature 0 degC to +55 degC

Connections / Interfaces

Interface or Terminal Function
DeviceNet (M12) Network communication with integrated T-connector loop-through
I/O Sockets (M12) Connection of 4-channel digital inputs and 4-channel digital outputs
Power Supply (M8) Control voltage and load voltage distribution

Installation Guidelines

  1. Verify that the incoming power supplies are fully de-energized before mounting.
  2. Securely mount the housing of the Fieldbus Box to a flat, vibration-free surface using the designated mounting holes.
  3. Connect the DeviceNet network cables to the integrated M12 T-connector interface, ensuring correct alignment.
  4. Plug the digital sensor and actuator lines into the correct M12 signal sockets.
  5. Tighten all M12 and M8 collars to the recommended torque specifications to preserve the unit's IP67 water and dust ingress rating.
  6. Apply system power and verify channel function and network state using the onboard diagnostics LEDs.
Loading product navigation…

What is the primary function of the BECKHOFF IP2302-B528?

The BECKHOFF IP2302-B528 is an IP67-rated Fieldbus Box designed to acquire four digital input signals and control four digital outputs via a DeviceNet network interface.

What connector standard does the BECKHOFF IP2302-B528 use for field devices?

The BECKHOFF IP2302-B528 features standard industrial M12 screw connectors for secure, moisture-resistant sensor, actuator, and network wiring.

Does the BECKHOFF IP2302-B528 require a separate network T-connector?

No, the BECKHOFF IP2302-B528 includes an integrated DeviceNet T-connector on the housing, allowing direct daisy-chain connection of network lines without external splitters.

What is the electrical load capacity for the outputs on the BECKHOFF IP2302-B528?

The BECKHOFF IP2302-B528 supports up to 0.5 A per output channel, operating on a nominal 24 V DC supply.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...