BECKHOFF

BECKHOFF IP2311-B318 Fieldbus Box

SKU IP2311-B318

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP2311-B318
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Dimensions: 30 mm x 210 mm x 26.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP2311-B318 is a compact Fieldbus Box module designed for decentralized automation tasks, combining four digital inputs, four digital outputs, and a PROFIBUS DP network interface within a single, highly protected housing. This module provides direct connection of sensors and actuators to PROFIBUS DP networks without requiring an additional coupling unit, simplifying decentralized system architectures.

With its sealed polyamide housing and high protection rating, the BECKHOFF IP2311-B318 is optimized for mounting directly on machines and equipment outside of traditional control cabinets. This minimizes wiring complexity, reduces overall space requirements, and maintains high signal integrity in demanding industrial settings. Signal and connection routing is achieved via standardized M8 and M12 connection interfaces.

Features

  • Direct integration with PROFIBUS DP networks via integrated B-coded M12 loop-through connections.
  • Automatic baud rate detection up to 12 Mbaud for flexible network integration.
  • Four 24 V DC digital inputs with a hardware input filter of 0.2 ms for fast, reliable signal recognition.
  • Four 24 V DC digital outputs handling up to 0.5 A per channel, suitable for resistive, inductive, and lamp loads.
  • Individually short-circuit proof digital outputs with diagnostic capabilities.
  • Short-circuit protected sensor supply of up to 0.5 A derived from the control voltage.
  • Direct machine installation enabled by a fully sealed, rugged PA6 housing.

Applications

  • Decentralized input/output collection on physical machines and assembly lines.
  • Machine-mount automation configurations lacking control cabinet space.
  • Wet or dusty operating environments requiring high IP protection classes.
  • Material handling systems, conveyor systems, and distributed process setups.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2311-B318
Product Type Fieldbus Box
Material PA6 (polyamide)
Installation 2 fixing holes, 3.5 mm diameter (for M3 screws)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm

Digital Inputs

Parameter Specification
Number of Channels 4
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V, 6 mA input current (EN 61131-2, type 2)
Input Filter 0.2 ms
Sensor Supply From control voltage, max. 0.5 A total, short-circuit proof

Digital Outputs

Parameter Specification
Number of Channels 4
Nominal Voltage 24 V DC (-15% / +20%)
Load Type Ohmic, inductive, lamp load
Max. Output Current 0.5 A per channel, individually short-circuit proof
Short-Circuit Current Typically 1.5 A

Electrical and Supply

Parameter Specification
Control Voltage Us 24 V DC (-15% / +20%)
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs/outputs: According to I/O type

Fieldbus and Communication

Parameter Specification
Protocol PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Options Via KS2000 tool or the controller (DP-V1 extensions supported)

Environmental and Mechanical

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Connections / Interfaces

Interface / Terminal Function
Bus Interface (1 x M12 plug, 5-pin) PROFIBUS DP incoming, B-coded
Bus Interface (1 x M12 socket, 5-pin) PROFIBUS DP outgoing, B-coded (integrated T-connector)
I/O Connections (M8, screw-type) Sensor and actuator connection points
Power Supply (1 x M8 male, 4-pin) 24 V DC power feed (Us and Up)
Power Supply (1 x M8 female, 4-pin) Downstream power distribution loop

Installation Guidelines

  1. Verify the system architecture and ensure the exact model (IP2311-B318) is compatible with your controller configuration.
  2. De-energize all system and field power supplies prior to starting the mechanical installation.
  3. Mount the module onto a flat surface using the two 3.5 mm diameter fixing holes with appropriate M3 fasteners.
  4. Verify and ensure clean routing for the M12 PROFIBUS DP connections and the M8 power distribution cabling.
  5. Hand-tighten all M8 and M12 connections to their designated torque limit to guarantee the IP65/66/67 environmental sealing.
  6. Verify ground connections and apply power to perform the initial startup and bus configuration sequence.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2311-B318?
The BECKHOFF IP2311-B318 is a decentralized Fieldbus Box designed to connect four digital inputs and four digital outputs directly to a PROFIBUS DP network without requiring a local control cabinet.
What connection standards are used for the signals on the IP2311-B318?
The BECKHOFF IP2311-B318 uses B-coded M12 connections for its integrated PROFIBUS DP interface (allowing loop-through topology) and standardized M8 screw-type connectors for digital inputs, outputs, and power lines.
Does the IP2311-B318 require a specific enclosure to achieve its IP67 rating?
No, the BECKHOFF IP2311-B318 is built in a sealed, protective polyamide housing, achieving an IP65, IP66, and IP67 protection rating when all connections are properly mated, allowing direct machine mounting.
What are the power requirements for the digital outputs of this module?
The digital outputs of the BECKHOFF IP2311-B318 are rated for 24 V DC and can supply a maximum current of 0.5 A per channel. Each output channel is individually short-circuit proof.
Reviews

IP2311-B318

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2311-B318 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2311-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2311-B318 is a compact Fieldbus Box module designed for decentralized automation tasks, combining four digital inputs, four digital outputs, and a PROFIBUS DP network interface within a single, highly protected housing. This module provides direct connection of sensors and actuators to PROFIBUS DP networks without requiring an additional coupling unit, simplifying decentralized system architectures.

With its sealed polyamide housing and high protection rating, the BECKHOFF IP2311-B318 is optimized for mounting directly on machines and equipment outside of traditional control cabinets. This minimizes wiring complexity, reduces overall space requirements, and maintains high signal integrity in demanding industrial settings. Signal and connection routing is achieved via standardized M8 and M12 connection interfaces.

Features

  • Direct integration with PROFIBUS DP networks via integrated B-coded M12 loop-through connections.
  • Automatic baud rate detection up to 12 Mbaud for flexible network integration.
  • Four 24 V DC digital inputs with a hardware input filter of 0.2 ms for fast, reliable signal recognition.
  • Four 24 V DC digital outputs handling up to 0.5 A per channel, suitable for resistive, inductive, and lamp loads.
  • Individually short-circuit proof digital outputs with diagnostic capabilities.
  • Short-circuit protected sensor supply of up to 0.5 A derived from the control voltage.
  • Direct machine installation enabled by a fully sealed, rugged PA6 housing.

Applications

  • Decentralized input/output collection on physical machines and assembly lines.
  • Machine-mount automation configurations lacking control cabinet space.
  • Wet or dusty operating environments requiring high IP protection classes.
  • Material handling systems, conveyor systems, and distributed process setups.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2311-B318
Product Type Fieldbus Box
Material PA6 (polyamide)
Installation 2 fixing holes, 3.5 mm diameter (for M3 screws)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm

Digital Inputs

Parameter Specification
Number of Channels 4
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V, 6 mA input current (EN 61131-2, type 2)
Input Filter 0.2 ms
Sensor Supply From control voltage, max. 0.5 A total, short-circuit proof

Digital Outputs

Parameter Specification
Number of Channels 4
Nominal Voltage 24 V DC (-15% / +20%)
Load Type Ohmic, inductive, lamp load
Max. Output Current 0.5 A per channel, individually short-circuit proof
Short-Circuit Current Typically 1.5 A

Electrical and Supply

Parameter Specification
Control Voltage Us 24 V DC (-15% / +20%)
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs/outputs: According to I/O type

Fieldbus and Communication

Parameter Specification
Protocol PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Options Via KS2000 tool or the controller (DP-V1 extensions supported)

Environmental and Mechanical

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Connections / Interfaces

Interface / Terminal Function
Bus Interface (1 x M12 plug, 5-pin) PROFIBUS DP incoming, B-coded
Bus Interface (1 x M12 socket, 5-pin) PROFIBUS DP outgoing, B-coded (integrated T-connector)
I/O Connections (M8, screw-type) Sensor and actuator connection points
Power Supply (1 x M8 male, 4-pin) 24 V DC power feed (Us and Up)
Power Supply (1 x M8 female, 4-pin) Downstream power distribution loop

Installation Guidelines

  1. Verify the system architecture and ensure the exact model (IP2311-B318) is compatible with your controller configuration.
  2. De-energize all system and field power supplies prior to starting the mechanical installation.
  3. Mount the module onto a flat surface using the two 3.5 mm diameter fixing holes with appropriate M3 fasteners.
  4. Verify and ensure clean routing for the M12 PROFIBUS DP connections and the M8 power distribution cabling.
  5. Hand-tighten all M8 and M12 connections to their designated torque limit to guarantee the IP65/66/67 environmental sealing.
  6. Verify ground connections and apply power to perform the initial startup and bus configuration sequence.
Loading product navigation…

What is the primary function of the BECKHOFF IP2311-B318?

The BECKHOFF IP2311-B318 is a decentralized Fieldbus Box designed to connect four digital inputs and four digital outputs directly to a PROFIBUS DP network without requiring a local control cabinet.

What connection standards are used for the signals on the IP2311-B318?

The BECKHOFF IP2311-B318 uses B-coded M12 connections for its integrated PROFIBUS DP interface (allowing loop-through topology) and standardized M8 screw-type connectors for digital inputs, outputs, and power lines.

Does the IP2311-B318 require a specific enclosure to achieve its IP67 rating?

No, the BECKHOFF IP2311-B318 is built in a sealed, protective polyamide housing, achieving an IP65, IP66, and IP67 protection rating when all connections are properly mated, allowing direct machine mounting.

What are the power requirements for the digital outputs of this module?

The digital outputs of the BECKHOFF IP2311-B318 are rated for 24 V DC and can supply a maximum current of 0.5 A per channel. Each output channel is individually short-circuit proof.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...