The BECKHOFF IP2322-B310 is a stand-alone Fieldbus Box designed for decentralized automation environments where direct-to-machine mounting is required. By integrating digital inputs, digital outputs, and an on-board industrial interface, this module allows machine builders to acquire digital sensor signals and control actuators directly in the field without utilizing space in a central control cabinet.

Featuring a dust-tight and water-resistant construction, the BECKHOFF IP2322-B310 functions as a reliable remote I/O node in demanding environments. Field connection points are laid out using industry-standard M12 screw-type connectors, minimizing wiring errors and speeding up installation and maintenance operations.

Features

  • Onboard PROFIBUS DP interface for high-speed integration into master controllers.
  • Four digital inputs (24 V DC) featuring a 3 ms input filter for sensor signal stability.
  • Four digital outputs (24 V DC) with up to 2 A switching capacity per channel for driving solenoids, valves, and actuators.
  • M12 connection technology for direct, screw-locked sensor and actuator wiring.
  • IP67 protection rating for mounting in wet, dusty, or mechanically demanding environments.
  • Local diagnostics via integrated status LEDs representing operating state, communication, and module power supply.

Applications

  • Decentralized control architectures where space-saving, cabinet-free installation is required.
  • Packaging, conveyor, and materials handling systems where long wiring runs to centralized control panels are impractical.
  • Industrial manufacturing environments with exposure to splashing water, oil, or particulate matter.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2322-B310
Product Type Fieldbus Box
Fieldbus Protocol PROFIBUS DP
Data Transfer Rates Up to 12 Mbaud
Number of Digital Inputs 4
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 3 ms
Number of Digital Outputs 4
Nominal Output Voltage 24 V DC
Max. Output Current 2 A per channel
I/O Connection Technology M12 screw-type
Protection Class IP67
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC

Installation Guidelines

  1. Ensure all power supplies and fieldbus network rings are de-energized before mounting the device.
  2. Mount the BECKHOFF IP2322-B310 to a flat, rigid machine surface using the integrated mounting holes.
  3. Connect the PROFIBUS DP fieldbus cables to the designated fieldbus interface socket.
  4. Wire the 24 V DC power supply line to the power input port of the box.
  5. Connect the M12 digital input and output cables to their corresponding numbered ports.
  6. To maintain the IP67 protection class, seal all unused M12 ports with suitable protective caps.
  7. Set the desired PROFIBUS station address on the rotary switches before initializing network startup.

Replacement Recommendations

When replacing a faulty BECKHOFF IP2322-B310, always record the physical switch settings for the PROFIBUS node address on the existing module. The replacement box must be configured with identical physical address settings prior to powering up to avoid fieldbus communication faults or master configuration mismatches.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2322-B310?
The BECKHOFF IP2322-B310 is a Fieldbus Box designed to connect four digital inputs and four digital outputs directly to a PROFIBUS DP network without requiring a protective control cabinet.
Does the BECKHOFF IP2322-B310 require an IP-rated enclosure?
No, the BECKHOFF IP2322-B310 features an integrated IP67 protection rating, meaning it is protected against dust and temporary liquid immersion, allowing it to be mounted directly onto machine frames.
What is the maximum output current supported by the BECKHOFF IP2322-B310 outputs?
Each of the four digital outputs on the BECKHOFF IP2322-B310 can supply a maximum switching current of up to 2 A at 24 V DC.
How are connections made to the BECKHOFF IP2322-B310?
Sensors and actuators connect to the BECKHOFF IP2322-B310 using industry-standard M12 screw-type connectors to ensure a secure, sealed interface.
How do you set the network address on the BECKHOFF IP2322-B310?
The network address for the BECKHOFF IP2322-B310 on the PROFIBUS DP segment is set manually using the physical rotary decimal switches located under the protective screw cap on the module.
Reviews

IP2322-B310

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2322-B310 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2322-B310

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2322-B310 is a stand-alone Fieldbus Box designed for decentralized automation environments where direct-to-machine mounting is required. By integrating digital inputs, digital outputs, and an on-board industrial interface, this module allows machine builders to acquire digital sensor signals and control actuators directly in the field without utilizing space in a central control cabinet.

Featuring a dust-tight and water-resistant construction, the BECKHOFF IP2322-B310 functions as a reliable remote I/O node in demanding environments. Field connection points are laid out using industry-standard M12 screw-type connectors, minimizing wiring errors and speeding up installation and maintenance operations.

Features

  • Onboard PROFIBUS DP interface for high-speed integration into master controllers.
  • Four digital inputs (24 V DC) featuring a 3 ms input filter for sensor signal stability.
  • Four digital outputs (24 V DC) with up to 2 A switching capacity per channel for driving solenoids, valves, and actuators.
  • M12 connection technology for direct, screw-locked sensor and actuator wiring.
  • IP67 protection rating for mounting in wet, dusty, or mechanically demanding environments.
  • Local diagnostics via integrated status LEDs representing operating state, communication, and module power supply.

Applications

  • Decentralized control architectures where space-saving, cabinet-free installation is required.
  • Packaging, conveyor, and materials handling systems where long wiring runs to centralized control panels are impractical.
  • Industrial manufacturing environments with exposure to splashing water, oil, or particulate matter.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2322-B310
Product Type Fieldbus Box
Fieldbus Protocol PROFIBUS DP
Data Transfer Rates Up to 12 Mbaud
Number of Digital Inputs 4
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 3 ms
Number of Digital Outputs 4
Nominal Output Voltage 24 V DC
Max. Output Current 2 A per channel
I/O Connection Technology M12 screw-type
Protection Class IP67
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC

Installation Guidelines

  1. Ensure all power supplies and fieldbus network rings are de-energized before mounting the device.
  2. Mount the BECKHOFF IP2322-B310 to a flat, rigid machine surface using the integrated mounting holes.
  3. Connect the PROFIBUS DP fieldbus cables to the designated fieldbus interface socket.
  4. Wire the 24 V DC power supply line to the power input port of the box.
  5. Connect the M12 digital input and output cables to their corresponding numbered ports.
  6. To maintain the IP67 protection class, seal all unused M12 ports with suitable protective caps.
  7. Set the desired PROFIBUS station address on the rotary switches before initializing network startup.

Replacement Recommendations

When replacing a faulty BECKHOFF IP2322-B310, always record the physical switch settings for the PROFIBUS node address on the existing module. The replacement box must be configured with identical physical address settings prior to powering up to avoid fieldbus communication faults or master configuration mismatches.

Loading product navigation…

What is the primary function of the BECKHOFF IP2322-B310?

The BECKHOFF IP2322-B310 is a Fieldbus Box designed to connect four digital inputs and four digital outputs directly to a PROFIBUS DP network without requiring a protective control cabinet.

Does the BECKHOFF IP2322-B310 require an IP-rated enclosure?

No, the BECKHOFF IP2322-B310 features an integrated IP67 protection rating, meaning it is protected against dust and temporary liquid immersion, allowing it to be mounted directly onto machine frames.

What is the maximum output current supported by the BECKHOFF IP2322-B310 outputs?

Each of the four digital outputs on the BECKHOFF IP2322-B310 can supply a maximum switching current of up to 2 A at 24 V DC.

How are connections made to the BECKHOFF IP2322-B310?

Sensors and actuators connect to the BECKHOFF IP2322-B310 using industry-standard M12 screw-type connectors to ensure a secure, sealed interface.

How do you set the network address on the BECKHOFF IP2322-B310?

The network address for the BECKHOFF IP2322-B310 on the PROFIBUS DP segment is set manually using the physical rotary decimal switches located under the protective screw cap on the module.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...