BECKHOFF

BECKHOFF IP2322-B528 Fieldbus Box

SKU IP2322-B528

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2322-B528

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF IP2322-B528 is a high-performance Fieldbus Box designed for direct machine installation in demanding industrial environments. By providing localized processing of digital inputs and outputs, this module eliminates the need for protective control cabinets, reducing wiring overhead and simplifying decentralized system architectures.

Equipped with a DeviceNet interface, the IP2322-B528 integrates an onboard T-connector to streamline daisy-chain bus connections. The module features 4 digital inputs with a 3 ms filter constant alongside 4 digital outputs capable of switching loads up to 2 A, making it suitable for driving actuators and interfacing with industrial sensors directly in the field.

Features

  • Direct integration into DeviceNet networks with an integrated T-connector.
  • 4 digital inputs (24 V DC) with a 3 ms input filter for signal reliability.
  • 4 digital outputs (24 V DC) with a high switching capacity of 2 A per channel.
  • M12 connection technology for secure, vibration-resistant sensor and actuator connections.
  • IP67-rated enclosure for dust and water protection without protective enclosures.

Applications

  • Decentralized input and output acquisition on DeviceNet industrial networks.
  • Direct control of high-current actuators and pneumatic valves up to 2 A.
  • Machine tool, conveyor system, and packaging machinery automation.
  • Environments requiring high protection ratings against moisture, dust, and mechanical stress.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2322-B528
Product Type Fieldbus Box
Fieldbus Interface DeviceNet (integrated T-connector)
Number of Digital Inputs 4
Input Filter Time 3 ms
Nominal Input Voltage 24 V DC
Number of Digital Outputs 4
Nominal Output Voltage 24 V DC
Max. Output Current 2 A per channel
I/O Connection Technology M12 screw connectors
Protection Class IP67

Installation Guidelines

  1. Ensure the system power supply is completely de-energized before beginning installation or maintenance.
  2. Mount the Fieldbus Box directly onto a flat, stable machine surface using the integrated mounting holes.
  3. Connect the DeviceNet network cabling utilizing the integrated T-connector on the module.
  4. Configure the DeviceNet node address (MAC ID) and baud rate according to network specifications prior to commissioning.
  5. Securely wire the sensors and actuators to the M12 I/O ports. Tighten all unused connectors with appropriate protective caps to preserve the IP67 sealing rating.
  6. Apply power to the unit and verify connection status via the local diagnostic indicators.

Replacement Recommendations

When replacing an active IP2322-B528 module, record the physical node address (MAC ID) and communication parameters of the existing unit. Ensure the replacement device is configured with identical address and baud rate settings before mounting and powering the fieldbus network.

FAQ

What fieldbus protocol does the BECKHOFF IP2322-B528 support?

The BECKHOFF IP2322-B528 supports the DeviceNet fieldbus protocol and features an integrated T-connector for direct bus routing.

What are the digital input and output capabilities of the BECKHOFF IP2322-B528?

The BECKHOFF IP2322-B528 is equipped with 4 digital inputs (24 V DC, 3 ms filter constant) and 4 digital outputs (24 V DC) supporting a switching current of up to 2 A per channel.

What protection rating does the BECKHOFF IP2322-B528 have?

The BECKHOFF IP2322-B528 has an IP67 protection rating, allowing it to be mounted directly onto machinery in harsh, wet, or dusty industrial environments without requiring a control cabinet.

What connection technology is used for I/O on the BECKHOFF IP2322-B528?

The BECKHOFF IP2322-B528 utilizes standard industrial M12 screw connectors for secure, vibration-resistant sensor and actuator connections.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.