BECKHOFF

BECKHOFF IP2401-B518 Fieldbus Box

SKU IP2401-B518

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP2401-B518
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP2401-B518 is a high-performance CANopen Coupler Box designed for the Fieldbus Box decentralized I/O system. This module serves as a robust gateway between a CANopen industrial network and local extension modules, enabling efficient data acquisition and control directly on machinery without requiring a traditional protective control cabinet.

Engineered for demanding industrial environments, the BECKHOFF IP2401-B518 features fully sealed, compact housing that provides exceptional resistance to moisture, dust, vibration, and mechanical shock. Its integrated M12 T-connector configuration simplifies network topology by allowing direct daisy-chaining of the CANopen bus interface, minimizing cabling complexity and installation time.

Features

  • Direct interface between CANopen networks and decentralized Fieldbus Box extension modules.
  • Integrated CANopen T-connector utilizing one M12 plug and one M12 socket.
  • Automatic detection of data transfer rates ranging from 10 kbaud up to 1 Mbaud.
  • Supports up to 16 send and 16 receive Process Data Objects (PDOs).
  • Comprehensive CANopen features including life guarding, node guarding, emergency objects, variable mapping, and store/restore parameters.
  • Flexible configuration options via the KS2000 serial interface or directly through the controller using Service Data Objects (SDOs).
  • Sealed IP65/66/67 rated enclosure suitable for direct wet-area or high-vibration mounting.

Applications

  • Decentralized machine control and cabinet-free automation architectures.
  • Modular machine manufacturing requiring rapid fieldbus integration.
  • Harsh environmental installations exposed to dust, fluids, or direct washdown.
  • Distributed data collection across extended CANopen networks.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP2401-B518
Product Type Fieldbus Box Coupler
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals and Markings CE, UL

CANopen and Fieldbus Communication

Parameter Specification
Protocol CANopen
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated T-connector
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of PDOs 16 send and 16 receive process data objects
I/O Communication Types Event-driven, cyclic, synchronous, polling
Data Transfer Medium Shielded copper cable, 2 x signal, 1 x CAN ground (recommended)

Electrical Data

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (maximum 0.5 A)
Electrical Isolation Control voltage / fieldbus: 500 V

Connections / Interfaces

Interface or Terminal Function
M12 Plug (5-pin) CANopen Network Input
M12 Socket (5-pin) CANopen Network Output (Loop-through)
M8 Male Connector (4-pin) 24 V DC Control Voltage Feed
M8 Female Connector (4-pin) Downstream Power Connection to extension modules

Installation Guidelines

  1. Verify that the model number IP2401-B518 matches your system configuration requirements before beginning installation.
  2. Ensure all electrical power sources (control voltage and load supply) are completely de-energized before mounting or wiring the module.
  3. Mount the device flat on a stable machine surface or mounting rail using appropriate fastening screws through the integrated mounting points.
  4. Connect the CANopen bus cables using the M12 plug and socket, ensuring the connectors are threaded hand-tight to maintain the IP67 environmental seal.
  5. Attach the 24 V DC control voltage to the M8 male feed connector, and use the M8 female connector for downstream power routing if connecting extension modules.
  6. Verify shielding and ground connections of the CANopen network to prevent electromagnetic interference.
  7. Power up the controller and verify normal operation via the diagnostic LEDs.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2401-B518?
The BECKHOFF IP2401-B518 is a CANopen Fieldbus Box coupler designed to connect decentralized extension modules to a CANopen fieldbus network in a cabinet-free control architecture.
How is the BECKHOFF IP2401-B518 configured?
The BECKHOFF IP2401-B518 can be configured using either the KS2000 configuration software or directly through the master controller using standard Service Data Objects (SDOs).
Does the BECKHOFF IP2401-B518 support automatic baud rate detection?
Yes, the BECKHOFF IP2401-B518 features automatic detection of CANopen data transfer rates ranging from 10 kbaud up to 1 Mbaud.
What are the power supply connection specifications for the BECKHOFF IP2401-B518?
The BECKHOFF IP2401-B518 requires a 24 V DC control voltage connected via a 4-pin M8 male socket, and provides a 4-pin M8 female socket for downstream power supply to extension modules.
What is the environmental protection rating of the BECKHOFF IP2401-B518?
The BECKHOFF IP2401-B518 is rated IP65, IP66, and IP67, making it fully sealed against dust, water spray, and temporary immersion for direct mounting on industrial machinery.
Reviews

IP2401-B518

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2401-B518 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2401-B518

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2401-B518 is a high-performance CANopen Coupler Box designed for the Fieldbus Box decentralized I/O system. This module serves as a robust gateway between a CANopen industrial network and local extension modules, enabling efficient data acquisition and control directly on machinery without requiring a traditional protective control cabinet.

Engineered for demanding industrial environments, the BECKHOFF IP2401-B518 features fully sealed, compact housing that provides exceptional resistance to moisture, dust, vibration, and mechanical shock. Its integrated M12 T-connector configuration simplifies network topology by allowing direct daisy-chaining of the CANopen bus interface, minimizing cabling complexity and installation time.

Features

  • Direct interface between CANopen networks and decentralized Fieldbus Box extension modules.
  • Integrated CANopen T-connector utilizing one M12 plug and one M12 socket.
  • Automatic detection of data transfer rates ranging from 10 kbaud up to 1 Mbaud.
  • Supports up to 16 send and 16 receive Process Data Objects (PDOs).
  • Comprehensive CANopen features including life guarding, node guarding, emergency objects, variable mapping, and store/restore parameters.
  • Flexible configuration options via the KS2000 serial interface or directly through the controller using Service Data Objects (SDOs).
  • Sealed IP65/66/67 rated enclosure suitable for direct wet-area or high-vibration mounting.

Applications

  • Decentralized machine control and cabinet-free automation architectures.
  • Modular machine manufacturing requiring rapid fieldbus integration.
  • Harsh environmental installations exposed to dust, fluids, or direct washdown.
  • Distributed data collection across extended CANopen networks.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP2401-B518
Product Type Fieldbus Box Coupler
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals and Markings CE, UL

CANopen and Fieldbus Communication

Parameter Specification
Protocol CANopen
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated T-connector
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of PDOs 16 send and 16 receive process data objects
I/O Communication Types Event-driven, cyclic, synchronous, polling
Data Transfer Medium Shielded copper cable, 2 x signal, 1 x CAN ground (recommended)

Electrical Data

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (maximum 0.5 A)
Electrical Isolation Control voltage / fieldbus: 500 V

Connections / Interfaces

Interface or Terminal Function
M12 Plug (5-pin) CANopen Network Input
M12 Socket (5-pin) CANopen Network Output (Loop-through)
M8 Male Connector (4-pin) 24 V DC Control Voltage Feed
M8 Female Connector (4-pin) Downstream Power Connection to extension modules

Installation Guidelines

  1. Verify that the model number IP2401-B518 matches your system configuration requirements before beginning installation.
  2. Ensure all electrical power sources (control voltage and load supply) are completely de-energized before mounting or wiring the module.
  3. Mount the device flat on a stable machine surface or mounting rail using appropriate fastening screws through the integrated mounting points.
  4. Connect the CANopen bus cables using the M12 plug and socket, ensuring the connectors are threaded hand-tight to maintain the IP67 environmental seal.
  5. Attach the 24 V DC control voltage to the M8 male feed connector, and use the M8 female connector for downstream power routing if connecting extension modules.
  6. Verify shielding and ground connections of the CANopen network to prevent electromagnetic interference.
  7. Power up the controller and verify normal operation via the diagnostic LEDs.
Loading product navigation…

What is the primary function of the BECKHOFF IP2401-B518?

The BECKHOFF IP2401-B518 is a CANopen Fieldbus Box coupler designed to connect decentralized extension modules to a CANopen fieldbus network in a cabinet-free control architecture.

How is the BECKHOFF IP2401-B518 configured?

The BECKHOFF IP2401-B518 can be configured using either the KS2000 configuration software or directly through the master controller using standard Service Data Objects (SDOs).

Does the BECKHOFF IP2401-B518 support automatic baud rate detection?

Yes, the BECKHOFF IP2401-B518 features automatic detection of CANopen data transfer rates ranging from 10 kbaud up to 1 Mbaud.

What are the power supply connection specifications for the BECKHOFF IP2401-B518?

The BECKHOFF IP2401-B518 requires a 24 V DC control voltage connected via a 4-pin M8 male socket, and provides a 4-pin M8 female socket for downstream power supply to extension modules.

What is the environmental protection rating of the BECKHOFF IP2401-B518?

The BECKHOFF IP2401-B518 is rated IP65, IP66, and IP67, making it fully sealed against dust, water spray, and temporary immersion for direct mounting on industrial machinery.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...