The BECKHOFF IP4132-B800 is a robust Fieldbus Box designed for decentralized industrial automation applications. Operating as a decentralized fieldbus device, it facilitates the connection of digital and analog peripheral signals directly at the machine level without requiring a control cabinet. Built with a high protection rating, the device integrates seamlessly into industrial networks using an open, documented protocol and provides reliable data transmission and power distribution in harsh factory environments.

This compact module features an integrated bus interface via a 5-pin M12 socket with B-coding and utilizes M8 connectors for power supply feed and downstream connection. It manages control voltage independently while supporting peripheral load requirements based on the connected I/O type. Configuration is supported via the KS2000 software tool, ensuring straightforward setup and maintenance within compatible automation architectures.

Features

  • Decentralized fieldbus box architecture designed for machine-level mounting without control cabinets
  • Integrated bus interface with one 5-pin M12 socket featuring B-coding
  • Power supply connection via one 4-pin M8 male socket for the feed and one 4-pin M8 female socket for downstream connection
  • Control voltage range of 24 V DC (-15 percent to +20 percent)
  • Box supply current rating of 45 mA plus sensor current consumption up to a maximum of 0.5 A
  • Configuration support via the KS2000 setup software
  • Electrical isolation between control voltage and the fieldbus interface
  • High protection rating of IP65, IP66, and IP67 for demanding industrial environments

Applications

    Decentralized machine automation and modular plant engineering
    Conveyor systems and material handling equipment
    Automotive manufacturing lines and assembly cells
    Packaging and sorting machinery

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP4132-B800
Product Type Fieldbus Box
Extension Modules None
Configuration Possibility Via KS2000

Electrical Specifications

Parameter Specification
Control Voltage Power Supply 24 V DC (-15 percent / +20 percent)
Load Voltage According to I/O type
Power Supply Connection Feed 1 x M8 male socket, 4-pin
Power Supply Connection Downstream 1 x M8 female socket, 4-pin
Box Supply Current 45 mA + current consumption of sensors, max. 0.5 A
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: yes; control voltage/inputs or outputs: according to I/O type

Communication and Signals

Parameter Specification
Bus Interface 1 x M12 socket, 5-pin, B-coded
Protocol Open, documented protocol
Digital Peripheral Signals According to I/O type
Analog Peripheral Signals According to I/O type

Mechanical and Environmental

Parameter Specification
Weight Approx. 210 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure the system is completely de-energized before beginning any mechanical installation or wiring work.
  2. Inspect the IP4132-B800 module and connection cables for any signs of transport damage.
  3. Mount the Fieldbus Box securely onto a flat machine surface in the desired variable orientation using appropriate fastening hardware.
  4. Connect the 24 V DC control voltage supply to the 4-pin M8 male socket feed and daisy-chain downstream devices using the 4-pin M8 female socket as needed.
  5. Attach the fieldbus communication cable to the 5-pin B-coded M12 socket.
  6. Verify that all signal lines, sensor connections, and shielding are properly secured and meet environmental protection requirements.
  7. Power on the system and perform initial configuration checks using the KS2000 software tool.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP4132-B800?
The BECKHOFF IP4132-B800 is a decentralized fieldbus box designed to connect digital and analog peripheral signals directly at machine level without requiring a control cabinet.
What type of bus interface does the BECKHOFF IP4132-B800 use?
The BECKHOFF IP4132-B800 features one 5-pin M12 socket with B-coding for fieldbus communication.
How is power supplied to the BECKHOFF IP4132-B800?
The BECKHOFF IP4132-B800 receives control voltage via a 4-pin M8 male socket feed and supports downstream power connection through a 4-pin M8 female socket.
What software is used to configure the BECKHOFF IP4132-B800?
Configuration for the BECKHOFF IP4132-B800 is performed using the KS2000 software tool.
What is the enclosure protection rating of the BECKHOFF IP4132-B800?
The BECKHOFF IP4132-B800 conforms to IP65, IP66, and IP67 protection ratings according to EN 60529 for demanding industrial environments.
Reviews

IP4132-B800

Stock & lead time on request

Call
1 of 1

BECKHOFF IP4132-B800 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP4132-B800

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 210g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP4132-B800 is a robust Fieldbus Box designed for decentralized industrial automation applications. Operating as a decentralized fieldbus device, it facilitates the connection of digital and analog peripheral signals directly at the machine level without requiring a control cabinet. Built with a high protection rating, the device integrates seamlessly into industrial networks using an open, documented protocol and provides reliable data transmission and power distribution in harsh factory environments.

This compact module features an integrated bus interface via a 5-pin M12 socket with B-coding and utilizes M8 connectors for power supply feed and downstream connection. It manages control voltage independently while supporting peripheral load requirements based on the connected I/O type. Configuration is supported via the KS2000 software tool, ensuring straightforward setup and maintenance within compatible automation architectures.

Features

  • Decentralized fieldbus box architecture designed for machine-level mounting without control cabinets
  • Integrated bus interface with one 5-pin M12 socket featuring B-coding
  • Power supply connection via one 4-pin M8 male socket for the feed and one 4-pin M8 female socket for downstream connection
  • Control voltage range of 24 V DC (-15 percent to +20 percent)
  • Box supply current rating of 45 mA plus sensor current consumption up to a maximum of 0.5 A
  • Configuration support via the KS2000 setup software
  • Electrical isolation between control voltage and the fieldbus interface
  • High protection rating of IP65, IP66, and IP67 for demanding industrial environments

Applications

    Decentralized machine automation and modular plant engineering
    Conveyor systems and material handling equipment
    Automotive manufacturing lines and assembly cells
    Packaging and sorting machinery

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP4132-B800
Product Type Fieldbus Box
Extension Modules None
Configuration Possibility Via KS2000

Electrical Specifications

Parameter Specification
Control Voltage Power Supply 24 V DC (-15 percent / +20 percent)
Load Voltage According to I/O type
Power Supply Connection Feed 1 x M8 male socket, 4-pin
Power Supply Connection Downstream 1 x M8 female socket, 4-pin
Box Supply Current 45 mA + current consumption of sensors, max. 0.5 A
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: yes; control voltage/inputs or outputs: according to I/O type

Communication and Signals

Parameter Specification
Bus Interface 1 x M12 socket, 5-pin, B-coded
Protocol Open, documented protocol
Digital Peripheral Signals According to I/O type
Analog Peripheral Signals According to I/O type

Mechanical and Environmental

Parameter Specification
Weight Approx. 210 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure the system is completely de-energized before beginning any mechanical installation or wiring work.
  2. Inspect the IP4132-B800 module and connection cables for any signs of transport damage.
  3. Mount the Fieldbus Box securely onto a flat machine surface in the desired variable orientation using appropriate fastening hardware.
  4. Connect the 24 V DC control voltage supply to the 4-pin M8 male socket feed and daisy-chain downstream devices using the 4-pin M8 female socket as needed.
  5. Attach the fieldbus communication cable to the 5-pin B-coded M12 socket.
  6. Verify that all signal lines, sensor connections, and shielding are properly secured and meet environmental protection requirements.
  7. Power on the system and perform initial configuration checks using the KS2000 software tool.
Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF IP4132-B800?

The BECKHOFF IP4132-B800 is a decentralized fieldbus box designed to connect digital and analog peripheral signals directly at machine level without requiring a control cabinet.

What type of bus interface does the BECKHOFF IP4132-B800 use?

The BECKHOFF IP4132-B800 features one 5-pin M12 socket with B-coding for fieldbus communication.

How is power supplied to the BECKHOFF IP4132-B800?

The BECKHOFF IP4132-B800 receives control voltage via a 4-pin M8 male socket feed and supports downstream power connection through a 4-pin M8 female socket.

What software is used to configure the BECKHOFF IP4132-B800?

Configuration for the BECKHOFF IP4132-B800 is performed using the KS2000 software tool.

What is the enclosure protection rating of the BECKHOFF IP4132-B800?

The BECKHOFF IP4132-B800 conforms to IP65, IP66, and IP67 protection ratings according to EN 60529 for demanding industrial environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.