The BECKHOFF IP5009-B400 is an Interbus-compatible Fieldbus Box module designed to establish a direct connection to absolute SSI encoders. Acting as a single-channel sensor interface, this module reads physical position information from absolute sensors and transmits the data directly to the higher-level Interbus system. Encased in a rugged polyamide XXL housing, this unit is engineered for direct installation on machinery and equipment, eliminating the need for a separate electrical enclosure.

The module is equipped with a high-speed RS485 difference signal interface capable of processing adjustable serial input lengths. Connection terminals include standardized M23 circular connectors for the absolute encoder and the Interbus network, coupled with compact M8 connectors for power routing. These robust physical connections ensure reliable communication and high ingress protection in industrial automation environments.

Features

  • Single-channel SSI absolute encoder interface for high-precision position feedback
  • Direct connection to Interbus networks using standardized M23 circular connections
  • RS485 difference signal input for reliable data transmission in electrically noisy environments
  • Configurable SSI data transfer rates with a standard default of 250 kHz
  • Short-circuit protected sensor power supply sourced directly from the control voltage
  • Durable polyamide housing providing IP65, IP66, and IP67 level protection
  • Compatible with the BECKHOFF KS2000 software suite for simplified parameters setup and diagnostics

Applications

  • Direct machine-mounted absolute position monitoring without protective control cabinets
  • Rotary and linear encoder integration in Interbus-based factory automation
  • Industrial motion control, material handling, and conveyor systems requiring absolute position feedback

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP5009-B400
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 350 g
Installation Mounting 2 x 3.5 mm diameter fixing holes for M3 screws

Electrical and Power Supply

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Control Voltage Supply 24 V DC (20...29 V DC)
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Sensor Supply From control voltage, max. 0.5 A, short-circuit proof
Encoder Supply 24 V DC, from load voltage
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)

Interbus and Communication

Parameter Specification
Fieldbus System Interbus
Bus Interface 1 x M23 female socket (9-pin), 1 x M23 male socket (9-pin)
Data Transfer Rate (Bus) 500 kBaud
Number of I/O Stations Dependent on the master (max. 256)
Data Transfer Medium LiYCY 3 x 2 x 0.22 mm² cable
Cable Length Max. 400 m between modules

SSI Interface

Parameter Specification
Number of Channels 1
SSI Encoder Connection M23 connector with outer thread, 12-pin
Signal Input Difference signal (RS485)
SSI Data Transfer Rates Variable up to 1 MHz (250 kHz default)
Serial Input 24 bits (adjustable)
Data Direction Read
Process Image Bit Width Input: 1 x 32-bit data (optional 1 x 8-bit control/status)

Environmental and Safety standards

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65/66/67 (conforms to EN 60529)
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure the system power supply is completely switched off and locked out prior to commencing installation.
  2. Inspect the BECKHOFF IP5009-B400 Fieldbus Box for any physical damage before mounting.
  3. Mount the module directly to a flat, vibration-free mounting surface using the two integrated 3.5 mm holes and appropriate M3 hardware.
  4. Connect the 12-pin M23 SSI encoder cable to the matching threaded connector on the module, ensuring the outer ring is fully tightened to maintain environmental integrity.
  5. Connect the Interbus input and output network cables to the M23 9-pin connections.
  6. Plug in the 4-pin M8 power connections, verifying correct polarity for both control and load voltages.
  7. Power on the system and observe the status LEDs to verify proper operation and interface communication.

Configuration Guidelines

To configure operational parameters such as the SSI transfer rate or serial input bit width, connect the BECKHOFF IP5009-B400 to a PC running the BECKHOFF KS2000 configuration software tool. Within the software interface, you can adjust the process image mapping and set the module properties according to the exact specifications of the connected absolute encoder.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP5009-B400?
The BECKHOFF IP5009-B400 is an Interbus Fieldbus Box module designed to act as a single-channel sensor interface, allowing direct connection of an absolute SSI encoder to an Interbus control network.
What type of connections are used on the BECKHOFF IP5009-B400?
The BECKHOFF IP5009-B400 uses a 12-pin M23 outer-threaded circular connector for the SSI encoder, 9-pin M23 connectors for the Interbus interface, and 4-pin M8 connectors for control and load power supplies.
Can the SSI parameters be adjusted on the BECKHOFF IP5009-B400?
Yes, the BECKHOFF IP5009-B400 supports adjustable serial input configurations up to 24 bits and variable data transfer rates up to 1 MHz (with a default of 250 kHz), which can be set up via the KS2000 software interface.
What environmental protection does the BECKHOFF IP5009-B400 housing offer?
The BECKHOFF IP5009-B400 is enclosed in a durable PA6 polyamide housing that conforms to IP65, IP66, and IP67 protection standards, enabling direct machine installation in harsh, wet, or dusty environments without an enclosure.
Reviews

IP5009-B400

Stock & lead time on request

Call
1 of 1

BECKHOFF IP5009-B400 Interbus Fieldbus Box SSI Encoder Interface

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP5009-B400

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF IP5009-B400 is an Interbus-compatible Fieldbus Box module designed to establish a direct connection to absolute SSI encoders. Acting as a single-channel sensor interface, this module reads physical position information from absolute sensors and transmits the data directly to the higher-level Interbus system. Encased in a rugged polyamide XXL housing, this unit is engineered for direct installation on machinery and equipment, eliminating the need for a separate electrical enclosure.

The module is equipped with a high-speed RS485 difference signal interface capable of processing adjustable serial input lengths. Connection terminals include standardized M23 circular connectors for the absolute encoder and the Interbus network, coupled with compact M8 connectors for power routing. These robust physical connections ensure reliable communication and high ingress protection in industrial automation environments.

Features

  • Single-channel SSI absolute encoder interface for high-precision position feedback
  • Direct connection to Interbus networks using standardized M23 circular connections
  • RS485 difference signal input for reliable data transmission in electrically noisy environments
  • Configurable SSI data transfer rates with a standard default of 250 kHz
  • Short-circuit protected sensor power supply sourced directly from the control voltage
  • Durable polyamide housing providing IP65, IP66, and IP67 level protection
  • Compatible with the BECKHOFF KS2000 software suite for simplified parameters setup and diagnostics

Applications

  • Direct machine-mounted absolute position monitoring without protective control cabinets
  • Rotary and linear encoder integration in Interbus-based factory automation
  • Industrial motion control, material handling, and conveyor systems requiring absolute position feedback

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP5009-B400
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 350 g
Installation Mounting 2 x 3.5 mm diameter fixing holes for M3 screws

Electrical and Power Supply

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Control Voltage Supply 24 V DC (20...29 V DC)
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)
Sensor Supply From control voltage, max. 0.5 A, short-circuit proof
Encoder Supply 24 V DC, from load voltage
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)

Interbus and Communication

Parameter Specification
Fieldbus System Interbus
Bus Interface 1 x M23 female socket (9-pin), 1 x M23 male socket (9-pin)
Data Transfer Rate (Bus) 500 kBaud
Number of I/O Stations Dependent on the master (max. 256)
Data Transfer Medium LiYCY 3 x 2 x 0.22 mm² cable
Cable Length Max. 400 m between modules

SSI Interface

Parameter Specification
Number of Channels 1
SSI Encoder Connection M23 connector with outer thread, 12-pin
Signal Input Difference signal (RS485)
SSI Data Transfer Rates Variable up to 1 MHz (250 kHz default)
Serial Input 24 bits (adjustable)
Data Direction Read
Process Image Bit Width Input: 1 x 32-bit data (optional 1 x 8-bit control/status)

Environmental and Safety standards

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Class IP65/66/67 (conforms to EN 60529)
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure the system power supply is completely switched off and locked out prior to commencing installation.
  2. Inspect the BECKHOFF IP5009-B400 Fieldbus Box for any physical damage before mounting.
  3. Mount the module directly to a flat, vibration-free mounting surface using the two integrated 3.5 mm holes and appropriate M3 hardware.
  4. Connect the 12-pin M23 SSI encoder cable to the matching threaded connector on the module, ensuring the outer ring is fully tightened to maintain environmental integrity.
  5. Connect the Interbus input and output network cables to the M23 9-pin connections.
  6. Plug in the 4-pin M8 power connections, verifying correct polarity for both control and load voltages.
  7. Power on the system and observe the status LEDs to verify proper operation and interface communication.

Configuration Guidelines

To configure operational parameters such as the SSI transfer rate or serial input bit width, connect the BECKHOFF IP5009-B400 to a PC running the BECKHOFF KS2000 configuration software tool. Within the software interface, you can adjust the process image mapping and set the module properties according to the exact specifications of the connected absolute encoder.

Loading product navigation…

What is the primary function of the BECKHOFF IP5009-B400?

The BECKHOFF IP5009-B400 is an Interbus Fieldbus Box module designed to act as a single-channel sensor interface, allowing direct connection of an absolute SSI encoder to an Interbus control network.

What type of connections are used on the BECKHOFF IP5009-B400?

The BECKHOFF IP5009-B400 uses a 12-pin M23 outer-threaded circular connector for the SSI encoder, 9-pin M23 connectors for the Interbus interface, and 4-pin M8 connectors for control and load power supplies.

Can the SSI parameters be adjusted on the BECKHOFF IP5009-B400?

Yes, the BECKHOFF IP5009-B400 supports adjustable serial input configurations up to 24 bits and variable data transfer rates up to 1 MHz (with a default of 250 kHz), which can be set up via the KS2000 software interface.

What environmental protection does the BECKHOFF IP5009-B400 housing offer?

The BECKHOFF IP5009-B400 is enclosed in a durable PA6 polyamide housing that conforms to IP65, IP66, and IP67 protection standards, enabling direct machine installation in harsh, wet, or dusty environments without an enclosure.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...