Description

Processing analog input signals within the Beckhoff I/O system, the BECKHOFF KL3042 Bus Terminal features two channels designed to acquire standard industrial currents ranging from 0 to 20 mA. This 12-bit resolution terminal operates on a single-ended technology scheme, providing highly reliable communication to the upper-level K-bus. By integrating an onboard sensor supply, this device minimizes the need for external distribution terminals, streamlining cabinet wiring in space-constrained industrial installations.

Features

  • Two single-ended analog input channels for standard current-loop signals
  • 12-bit digitization resolution for precise monitoring of process variables
  • Integrated sensor supply connection points routing 24 V DC directly to field transmitters
  • High-speed conversion timing optimizing PLC cycle responsiveness
  • Compact 12 mm housing width maximizing DIN-rail spatial density
  • Galvanic isolation rated at 500 V protecting the internal K-bus architecture

Applications

  • Continuous process monitoring (flowmeters, pressure transducers, level indicators)
  • HVAC environmental monitoring and pneumatic damper positioning systems
  • Water and wastewater municipal pump control panels
  • Factory automation machinery utilizing standard 0 to 20 mA loop transmitters

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Series KL Bus Terminal Series
Number of Inputs 2 channels
Signal Current Range 0 to 20 mA
Resolution 12-bit
Technology Type Single-ended
Internal Resistance 80 ohms + diode voltage 0.7 V
Conversion Time approx. 2 ms
Measurement Uncertainty < +/-0.3 percent (relative to full scale value)
Surge Voltage Resistance max. 35 V DC
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption (K-bus) typ. 65 mA
Process Image Bit Width Input: 2 x 16-bit data (2 x 8-bit control/status optional)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 percent, non-condensing
Protection Rating IP20 (variable installation position)
Approvals & Markings CE, UL, ATEX, IECEx, DNV GL
Ex Marking ATEX: II 3 G Ex ec IIC T4 Gc / IECEx: Ex ec IIC T4 Gc
Country of Origin Germany
Shipping Weight (Calculated) 0.07 kg (exclusive of protective packaging)

Connections and Interfaces

Terminal Connection Point Functional Assignment
1 Analog Input 1 (+)
2 Sensor Supply 1 (+24 V DC)
3 0 V Sensor Supply (connected internally with point 7)
4 Shield / Functional Earth (PE)
5 Analog Input 2 (+)
6 Sensor Supply 2 (+24 V DC)
7 0 V Sensor Supply (connected internally with point 3)
8 Shield / Functional Earth (PE)

Empirical Engineering Insights

Alternative Models & Compatibility

For installations requiring fast-disconnect options or pre-wired cable harnesses, transition to the KS3042 model, which features pluggable connection blocks with identical technical ratings. Ensure the K-bus coupler (e.g., BK9000 or BK1100) firmware is up to date to properly map the 2 x 16-bit process image in your TwinCAT System Manager software configuration.

Application Pitfalls & Engineering Notes

Because this is a single-ended input card, all channels share an internal common reference point. Connecting loop transmitters that have distinct, non-isolated grounds can generate ground-loop currents, resulting in measurement deviations or card errors. If utilizing active, externally powered 4-wire transmitters, ensure the loop signal remains isolated or shares a common 0 V DC potential with the cabinet supply bus.

Commissioning & Wiring Tips

Always route current loop cabling using shielded, twisted-pair lines. Terminate the shield directly to connections 4 and 8 (PE) at the terminal, or land them on an auxiliary shield clamp bus bar positioned directly at the entry of the control panel to minimize electromagnetic interference from neighboring variable frequency drives.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power contacts before inserting or removing any Bus Terminals from the node segment. Failure to do so can cause electric arcing, leading to physical damage to the internal K-bus contacts and system communications failure.
1

Mount the bus coupler on a standard 35 mm DIN rail (EN 60715) and lock it into place using the integrated rail clamp.

2

Slide the module along the guide slot of the adjacent terminal until the tongue-and-groove joint is fully locked.

3

Press the module firmly against the DIN rail until the side latching mechanism clicks, indicating secure grounding contact.

4

Using a standard flat-head screwdriver, insert wire leads into the tension clamp connection points and release the spring mechanism to complete the connection.

Loading product navigation…

What is the primary function of this 2-channel analog input terminal?

It measures analog DC currents in the 0 to 20 mA range with 12-bit resolution, transferring the processed digitized values to the fieldbus coupler over the K-bus.

Does this module require a separate power supply for the field sensors?

No, it features integrated sensor supply terminals that distribute 24 V DC power directly from the system power contacts to the connected loop transmitters.

What is the difference between single-ended and differential inputs in this context?

This single-ended module features input channels that share a common ground reference internally. Care must be taken to prevent ground loop offsets when wiring multiple active transmitters.

Are the connection blocks on this model removable?

No, this standard model has fixed tension clamps. If pluggable terminals are required for maintenance convenience, choose the pluggable KS-series version instead.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...