Description

Generating analog control signals within the Beckhoff I/O system, the KS4031 bus terminal delivers a high-precision, single-channel output ranging from -10 to +10 V. This specialized analog output terminal is built with pluggable wiring levels, simplifying installation and maintenance in dense control cabinets. Operating via the standard K-bus, the module isolates control-side logic from field-level actuator signals up to 500 V, providing superior noise immunity and protection for upstream PLC and industrial PC controllers.

Features

  • Single-channel analog output with a bipolar signal range of -10 V to +10 V.
  • High-resolution 12-bit signal conversion for precise control loop actuation.
  • Pluggable connection technology (KS series design) allowing fast wiring swaps without disconnecting field cables.
  • Complete galvanic isolation of 500 V between the internal K-bus and the field signal.
  • Short-circuit proof output circuitry with a minimum load resistance of 5 kOhm.
  • Diagnostic-friendly interface with optional control and status bytes alongside 16-bit output data in the process image.

Applications

  • Proportional valve control and hydraulic actuator positioning.
  • Speed reference setpoint transmission for variable frequency drives (VFDs).
  • Analog calibration reference in plant engineering and machine manufacturing.
  • Signal conversion in HVAC and building automation control cabinets.

Technical Specifications

Manufacturer Beckhoff
Part Number / Model KS4031
Number of Outputs 1
Signal Voltage -10 to +10 V
Resolution 12 bit
Conversion Time approx. 1.5 ms
Output Error < ±0.1% (relative to end value)
Load Impedance > 5 kOhm (short-circuit proof)
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus typ. 75 mA
Bit Width in Process Image Output: 1 x 16-bit data (1 x 8-bit control/status optional)
Connection Technology Pluggable wiring (spring actuation)
Connection Cross-Section Solid/Stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²
Connection Cross-Section AWG AWG 28 to 16
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.085 kg
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Ex Marking II 3 G Ex nA IIC T4 Gc
Approvals and Markings CE, UL, ATEX, DNVGL

Installation Guidelines

  • Mount the terminal on a standard 35 mm DIN rail (conforming to EN 60715) with the locking mechanism engaged.
  • Ensure that electrical power is entirely switched off before connecting or separating the pluggable wiring level.
  • To wire the terminal, actuate the internal spring clamp by pressing a standard flat-blade screwdriver into the release slot.
  • Maintain adequate ventilation clearance above and below the terminal block assembly to comply with the 0 to +55 degC operating envelope.

FAQ

What is the primary difference between the Beckhoff KL4031 and KS4031?

The KS4031 model features a pluggable wiring level block, allowing the terminal insert to be easily swapped for maintenance without disconnecting the field wiring. The KL4031 model has fixed, non-removable terminal blocks.

What are the output voltage range and signal resolution of the KS4031?

The KS4031 provides a single analog output channel with a signal range of -10 V to +10 V at a conversion resolution of 12 bits.

Does the KS4031 require an external auxiliary power connection?

No, the KS4031 is powered directly through the internal K-bus and does not utilize power contacts.

Is the analog output isolated from the control network?

Yes, the KS4031 features 500 V galvanic electrical isolation between the internal K-bus logic and the field-side analog output circuit.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...