What Is SCADA? Supervisory Control Without Replacing the PLC
SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.



Designed for cost-effective, continuous asset protection, the Bently Nevada 2300/20-CN vibration monitor provides reliable status assessment for critical and general-purpose rotating machinery. This dual-channel monitoring system processes input signals from proximity probes, accelerometers, or velocity transducers to evaluate overall vibration levels, axial position, or rotational speed. Implementing the 2300/20-CN within a facility's predictive maintenance framework enables operators to identify mechanical faults, unbalance, and structural misalignments prior to catastrophic equipment failure. The module features integrated Ethernet capabilities for Modbus TCP/IP communication and supports seamless connection to Bently Nevada's System 1 software for detailed asset condition monitoring and diagnostics.
| Manufacturer | Bently Nevada |
| Part Number | 2300/20-CN |
| Series | 2300 Series Machinery Monitor |
| Input Channels | 2 Dynamic Channels, 1 Speed/Keyphasor Channel |
| Sensor Support | Proximity Transducers, Accelerometers, Velomitors |
| Power Requirements | 24 VDC nominal (18 to 36 VDC range) |
| Communication Protocol | Modbus TCP/IP via Ethernet |
| Analog Outputs | Two 4-20 mA proportional current loops |
| Relay Outputs | Configurable SPDT dry contacts (Alarm, Danger, System OK) |
| Configuration Interface | RJ45 Ethernet port for local/remote software utility |
| Operating Temperature | -20 to +65 degC |
| Storage Temperature | -40 to +85 degC |
| Relative Humidity | Up to 95% non-condensing |
| Terminal Group | Function Description |
|---|---|
| PWR | +24 VDC Input and Common Power Return |
| CH 1 / CH 2 | Dynamic Sensor Inputs (Signal, Common, and -24 VDC Transducer Power) |
| KPH / SPD | Speed Sensor / Keyphasor Signal and Power Connections |
| OUT 1 / OUT 2 | 4-20 mA Analog Output Terminals |
| RELAYS | Normally Open (NO), Normally Closed (NC), and Common (COM) Contacts |
| ETHERNET | RJ45 Interface for Modbus TCP/IP & Configuration Software Connection |