1 of 1

Bently Nevada 3500/15-04-00-00 3500 Series Power Supply Module

Bently Nevada 3500/15-04-00-00 3500 Series Power Supply Module

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/15-04-00-00

  • Country of origin:United States

  • Product Type: Machinery Protection Power Supplies

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Providing steady, regulated power directly to the backplane of the machinery protection system, the Bently Nevada 3500/15-04-00-00 is an essential half-height power module. It is engineered to accept a low-voltage DC input source and convert it to the precise voltage rails required by other modules within the 3500 rack. Designed for high-reliability continuous operations, this specific variant features a single-supply configuration configured for the top slot, enabling a cost-effective setup where redundant power paths are not mandatory. It integrates advanced line filtering and transient suppression to protect sensitive diagnostic and monitoring instrumentation from field power anomalies.

Features

  • Low-Voltage DC Input: Specifically configured for 20 to 30 Vdc input ranges, ideal for industrial battery banks and localized DC distribution systems.
  • Single Supply Configuration: Optioned with a top-slot active supply and a bottom-slot blank configuration (no supply) to minimize unnecessary hardware overhead.
  • Internal Diagnostics: Continuously monitors output voltages and system status, reporting errors directly to the Rack Interface Module (RIM).
  • Integrated Protection: Features robust overvoltage, overcurrent, and short-circuit protection on all output rails to safeguard downstream machinery protection modules.
  • Front Panel Status LEDs: Includes high-visibility indicators for "Supply OK" and "Not OK" status verification at a glance.

Applications

  • Turbomachinery vibration and position monitoring systems.
  • Continuous monitoring of critical rotating assets in oil and gas refineries.
  • Power generation plant steam and gas turbine diagnostic racks.
  • Heavy industrial processing plants requiring unified rack-based instrumentation.

Technical Specifications

Parameter Value
Manufacturer Bently Nevada (Baker Hughes)
Model Number 3500/15-04-00-00
Series 3500 Machinery Protection System
Top Slot Power Supply Type Low Voltage DC (20 to 30 Vdc)
Bottom Slot Power Supply Type No Supply (00)
Agency Approvals None (00 Option)
Input Voltage Range 20 to 30 Vdc
Form Factor Half-height module (Fits designated slot on the far left of 3500 racks)
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 5.00 kg

Connections and Interfaces

Terminal / Port Function / Circuit Assignment
DC Input (+) Positive Supply Connection (20 to 30 Vdc)
DC Input (-) Negative / Common Return Connection
Chassis GND Earth Ground / Shield termination point for high-frequency noise redirection

Empirical Engineering Insights

Alternative Models & Compatibility

This unit occupies the top half of the left-most power slot of a 3500 rack. Because this specific part number is a single, low-voltage DC module (option 04) with no secondary supply in the bottom slot (option 00), it cannot provide redundant operations. If redundant backup power is later mandated on-site, the bottom slot cannot be easily field-retrofitted with a mismatching module; you must upgrade the entire power entry module assembly to support dual power feeds of identical voltage specifications.

Application Pitfalls & Engineering Notes

When deploying the low-voltage DC option in hot environments, ensure that enclosure cabinets maintain active ventilation. Low-voltage high-current DC systems exhibit greater localized thermal dissipation at the connection terminals compared to their high-voltage AC counterparts. Additionally, the bottom slot must be covered with a proper half-height blanking panel to preserve designed chassis convection cooling paths and prevent electromagnetic interference (EMI) ingress.

Commissioning & Wiring Tips

To prevent common-mode noise issues on highly sensitive proximity probes and seismic channels, run isolated DC power lines directly from a regulated industrial battery source rather than using utility lines shared with variable frequency drives (VFDs) or heavy inductive contactors. Use a minimum of 2.5 mm2 (14 AWG) stranded copper wire for the DC input lines to limit voltage drop across longer runs, as drop below 20 Vdc at the rack power terminals will trigger an immediate under-voltage fault flag.

Installation Guidelines

CRITICAL WARNING:

Never insert or remove a power supply module or its rear input card while the incoming power source is live. Arching on the power supply connectors can damage internal solid-state components and compromise the system backplane integrity. Verify complete electrical isolation before proceeding with installation or replacement procedures.

1
Mounting the Power Input Module (PIM): Fasten the rear PIM card securely into the designated slot on the back of the 3500 rack before inserting the front power supply module.
2
Inserting the Front Module: Slide the main power supply module into the top left half-height slot along the guide rails until it seats firmly into the backplane connector. Tighten the two captive thumbscrews by hand.
3
Wiring and Shielding: Connect the 24 Vdc supply lines to the terminals on the rear PIM card. Ensure the Chassis Ground terminal is connected to the cabinet's single-point earth ground utilizing low-impedance copper strap.
4
Power Application & Testing: Switch on the main DC distribution breaker. Verify that the green "Supply OK" LED on the front panel of the module illuminates and remains solid, confirming nominal voltage rail distribution.

Can I mix low-voltage DC and high-voltage AC supplies in a redundant Bently Nevada 3500 rack configuration?

No. Redundant power configurations must use identical power supply modules and power input cards. Combining different voltage types inside the same rack is unsafe and will cause damage.

What does the '00' selection for the bottom slot signify in this part number?

The '00' option indicates 'No Supply.' This means the module is configured as a single, non-redundant power source located solely in the top slot of the rack.

What is the acceptable input voltage range for the 3500/15-04-00-00 module?

This module is configured for low-voltage DC input and operates within a range of 20 to 30 Vdc.

Is the 3500/15-04-00-00 power supply hot-swappable?

Only in redundant configurations. Since this part number is a single-supply configuration (00 bottom slot), removing it will immediately power down the rack and stop all active monitoring.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.