1 of 1

CC-TAOX11 | Honeywell | Experion C300 Analog Output IOTA (16-Channel)

CC-TAOX11 | Honeywell | Experion C300 Analog Output IOTA (16-Channel)

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TAOX11

  • Country of origin:United States

  • Product Type: Analog Output IOTA

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The CC-TAOX11 is a high-density Analog Output Field Termination Assembly (IOTA) module designed for the Honeywell Experion C300 controller platform. This module serves as the physical interface for 16 independent channels, delivering a standardized 4-20 mA signal to field-side control elements such as valve positioners, variable speed drives, and actuators. Engineered for high-availability process environments, the CC-TAOX11 is widely deployed in oil and gas processing, large-scale power generation, and chemical manufacturing. Its primary function is to convert digital control commands from the C300 processor into precise analog currents, ensuring deterministic control of critical loops while maintaining low signal noise and high thermal stability.

Comprehensive Technical Parameter Matrix

The following table encapsulates the essential electrical and mechanical specifications for the CC-TAOX11 to support engineering design and cabinet layout planning.

Technical Parameter Specification Detail
Model Designation CC-TAOX11
Manufacturer Honeywell
Series Experion C300 / Series C
Output Type 4 to 20 mA (DC)
Channel Density 16 Channels
Output Ripple < 100 mV p-p (at power line frequency)
Load Resistance 250 Ohm (Standard Reference)
Coating Conformal Coating (Standard for Series C)
Terminal Type Compression or Screw Terminals
Redundancy Support Supports Redundant I/O Configurations
Mounting Series C I/O Termination Assembly
Shipping Weight 3.0 kg

Technical Performance & Application FAQ

Does the CC-TAOX11 support redundant configurations?Yes. As a Series C IOTA, the CC-TAOX11 is designed to support redundant I/O module pairs. In a redundant setup, if one Analog Output module fails, the second module maintains the 4-20 mA signal to the field without any bump in the process, ensuring continuous plant operation.

How does the 100 mV peak-to-peak ripple specification affect performance?The low ripple content (< 100 mV p-p) ensures that the control signal is "clean." This is particularly important for sensitive smart positioners or actuators that might misinterpret signal noise as a control command, which could otherwise lead to "hunting" or premature wear of mechanical components.

Is this module suitable for corrosive environments?Yes. The CC-TAOX11 typically features conformal coating as part of the Series C hardware standard. This provides superior protection against humidity, salt spray, and corrosive gases (such as H2S or SO2), making it ideal for offshore platforms and wastewater treatment facilities.


Engineering Deployment & Field Installation Guide

  • Termination and Wiring: When connecting field wiring to the 16 channels, ensure that high-quality twisted-pair shielded cable is used. The shield should be grounded at the IOTA end to minimize electromagnetic interference. The compression terminals are designed for ease of use, but ensure that no stray wire strands cause short circuits between adjacent channels.

  • Load Impedance Verification: The module is optimized for a 250 Ohm load. Before commissioning, verify the total loop resistance (including the field device and wire resistance). If the impedance is significantly outside the specified range, it may lead to current saturation or drive capability issues.

  • Redundancy Linkage: When installing for a redundant application, ensure the redundancy cable is properly seated between the primary and secondary I/O modules. The CC-TAOX11 IOTA provides the physical infrastructure to bridge these signals seamlessly.

Technical Superiority & System Resilience

The Honeywell CC-TAOX11 represents the gold standard in high-density analog control. By consolidating 16 channels into a single Series C footprint, it significantly reduces cabinet space requirements and simplifies field wiring architecture. As an Original and New component, it utilizes advanced diagnostic circuitry that can detect open circuits or shorted field loops, reporting these faults directly to the Experion HMI. This proactive diagnostic capability, combined with the module's robust electrical isolation and low power dissipation, makes the CC-TAOX11 a highly reliable asset for maintaining the peak efficiency of complex industrial control strategies.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...