CJ1W-ID212 | Omron | High-Speed DC Input Unit

CJ1W-ID212 | Omron | High-Speed DC Input Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CJ1W-ID212

  • Country of origin:Japan

  • Product Type: DC Input Unit

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The CJ1W-ID212 is a high-speed DC Input Unit designed for the Omron CJ-series PLC system. This unit provides 16 digital input points, engineered for applications requiring rapid signal acquisition. It operates at a nominal voltage of 24 VDC with a standard input current of 7 mA. The module is configured with 16 points per common, utilizing a removable terminal block for efficient wiring and maintenance. Occupying 1 word in the PLC process image, this unit is a space-effective solution for dense I/O requirements in automated machinery and production lines.

Features

  • 16 high-speed digital input points for fast signal processing
  • 24 VDC input voltage with 7 mA current draw
  • 16 points per common configuration
  • Removable terminal block for quick installation and replacement
  • Compact design allocating only 1 word of memory
  • Low current consumption (0.13 A at 5V)

Applications

  • High-speed production line monitoring
  • Fast-response sensor integration
  • Packaging and material handling automation
  • General-purpose digital signal interface for CJ-series PLC systems

Technical Specifications

Feature Specification
Manufacturer Omron
Part Number CJ1W-ID212
Device Type DC Input Unit
I/O Points 16 inputs (High speed)
Input Voltage 24 VDC
Input Current 7 mA
Commons 16 points, 1 common
External Connection Removable terminal block
Allocated Words 1 word
Current Consumption 0.13 A (at 5V)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Ensure the unit is securely seated on the CJ-series backplane. Lock the module using the sliders at the top and bottom to ensure a solid electrical connection.
  • Wiring: Use the removable terminal block for field wiring. Ensure wires are properly crimped or secured to prevent loose connections in high-vibration environments.
  • Commoning: Note that this unit uses 16 points per common. Ensure the common terminal is correctly wired to the 0V or 24V side of your power supply, depending on your PNP/NPN input sensor configuration.
  • Safety: Always disconnect power to the PLC system before installing or removing any I/O modules to prevent electrical arcs or damage to the backplane communication pins.

What is the primary advantage of the CJ1W-ID212 compared to standard input units?

The CJ1W-ID212 is specifically designated as a high-speed input unit, allowing for faster response times compared to standard DC input modules.

How many PLC memory words does this unit occupy?

The module occupies exactly 1 word in the process image of the PLC.

What type of connection is used for field wiring?

The unit features a removable terminal block, which allows for easy wiring and rapid module replacement without needing to disconnect individual wires.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Japan
Power source
DC Power

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...