BECKHOFF

CX5120-N031 BECKHOFF Intel Atom Embedded PC with Terminated RS485 Interface

SKU CX5120-N031

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX5120-N031

  • Country of origin:Germany

  • Product Type: Embedded PC with Intel Atom® processor

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The CX5120-N031 (CX5120N031) is a high-performance, fanless Embedded PC designed for DIN rail mounting, powered by an efficient Intel Atom® multi-core processor. This specific configuration is equipped with a factory-integrated RS485 interface via a 9-pin D-sub socket, specifically configured for use as an end point. In industrial B2B sectors such as building automation, renewable energy monitoring, and long-distance serial networking, the CX5120-N031 serves as a robust intelligent controller. It excels in bridging high-speed EtherCAT I/O with legacy serial bus systems, providing the computational overhead required for TwinCAT 3 PLC and Motion Control tasks while maintaining a rugged, maintenance-free hardware profile.

Technical Configuration (Deep Dive)

The CX5120-N031 is technically optimized for RS485 bus integrity. Unlike the -0002 variant, this "N031" model is pre-configured as an end point with termination on. This means the internal 120-ohm termination resistor is active, and the module is set to without echo (half-duplex). This configuration is critical for preventing signal reflections in serial RS485 networks, ensuring high-speed data reliability over long cable runs without the need for external resistors.

The unit leverages the advanced Intel Atom® architecture to deliver a superior performance-to-watt ratio. It supports automatic recognition of both E-bus (EtherCAT) and K-bus (Bus Terminals), allowing it to function as a universal head-station for any Beckhoff I/O segment. The fanless design ensures longevity in dusty or vibration-prone environments where active cooling would fail.

Technical Specifications

Attribute Specification Details
Model CX5120-N031
Brand BECKHOFF
Processor Intel Atom® (High-efficiency Multi-core)
Interface Type 1 x RS485
Connection Port 9-pin D-sub socket
RS485 Config End point, without echo, Termination ON
Expansion Bus Automatic E-bus / K-bus recognition
Cooling Fanless (Passive Convection)
Installation 35 mm DIN rail (EN 60715)
Operating Temp -25 to +60 Celsius
Weight Approx. 590 g
Protection Rating IP20
Power Supply 24 VDC (-15 % / +20 %)

Technical FAQs

What does "Termination ON" mean for my network design?

The CX5120-N031 has an internal 120-ohm resistor engaged across the RS485 data lines. This module must be placed at the physical beginning or the physical end of your RS485 daisy-chain to ensure impedance matching and prevent signal distortion.

Can I use this for Modbus RTU communication?

Absolutely. The RS485 interface is fully compatible with the Modbus RTU protocol. In TwinCAT, you can simply map the serial port to the Modbus RTU master or slave library to communicate with drives, meters, or third-party sensors.

Does this model support TwinCAT 3 Platform Level 40?

Yes. The CX5120 series typically operates at the Performance (40) platform level, providing ample power for multi-tasking PLC environments and complex communication handling.


Engineering & Installation Guide

  • Network Topology: Because this unit is configured with internal termination, avoid placing it in the middle of an RS485 bus. Doing so would load the bus incorrectly and likely cause communication errors. Always use shielded, twisted-pair cable for the D-sub connection.

  • Thermal Clearances: For fanless operation up to 60 Celsius, the unit must be mounted horizontally. Ensure a minimum of 30 mm of free space above and below the cooling fins to allow for natural heat dissipation.

  • Bus Integration: The CX5120 detects the connected I/O bus type during the boot phase. When switching from E-bus to K-bus terminals, ensure a complete power cycle of the system to allow the automatic bus recognition logic to reset.

Engineering Advantages

The CX5120-N031 represents a professional-grade solution for "Legacy-to-Industry 4.0" integration. By integrating a hardware-terminated RS485 port directly into a powerful Intel Atom® PC, it reduces the need for external gateways and specialized wiring. Its durability is proven by its compliance with EN 60068-2-6/27 for vibration and shock resistance, ensuring it remains operational in the most demanding industrial settings. The combination of high-speed local I/O expansion and ready-to-use serial networking makes it one of the most flexible Embedded PCs in the Beckhoff portfolio.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...