Danfoss

Danfoss 034G0508 ETS Series Electric Expansion Valve

SKU 034G0508

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 034G0508

  • Country of origin:Denmark

  • Product Type: Electric Expansion Valve

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 034G0508 (034G0508) by Danfoss is a high-precision electric expansion valve designed for precise liquid injection in air conditioning and refrigeration systems. Engineered for industrial-scale thermal management, this bi-flow component is critical in large-scale data center cooling, commercial HVAC, and food processing plants. By leveraging an advanced stepper motor drive, the 034G0508 ensures optimal evaporator utilization and stable superheat control even under fluctuating load conditions. This precision directly translates to enhanced energy efficiency and a significant reduction in compressor downtime, making it a cornerstone for mission-critical cooling infrastructure where thermal stability is non-negotiable.

Technical Configuration

The 034G0508 belongs to the ETS Colibri or similar high-performance stepper motor valve series. It features a sophisticated drive mechanism that converts electrical pulses into precise linear motion, allowing for fine-tuned refrigerant flow control. The integrated IP67 enclosure rating ensures the internal motor and electronics are fully protected against dust and temporary immersion, which is vital for environments with heavy condensation. Its Bi-flow capability allows the valve to manage refrigerant flow in both directions, making it ideal for heat pump applications or systems requiring reversible cycles without additional check valves. The 2-meter factory-fitted cable provides a reliable electrical interface with minimal signal attenuation.

Technical Specifications

Attribute Specification
Model 034G0508
Brand Danfoss
Product Type Electric Expansion Valve (EEV)
Flow Direction Bi-flow
Cable Length 2 m (6.6 ft)
Enclosure Rating IP67
Shipping Weight 3.0 kg
Operating Temperature -40 to 65 deg C
Refrigerants R410A, R407C, R404A, R134a, R22, R1234ze
Max. Working Pressure 45.5 bar
Actuator Type Stepper Motor

Technical FAQs

How do I verify if the 034G0508 is compatible with my existing PLC or controller?

The valve requires a bipolar stepper motor driver. Ensure your controller can output the correct current (typically 100 mA RMS) and step rate (approx. 150 steps per second) required by Danfoss ETS series specifications.

What is the primary benefit of the Bi-flow design in this specific model?

The Bi-flow design allows the valve to maintain identical flow characteristics and high-precision control in both heating and cooling modes, eliminating the need for complex piping and external solenoid valves in reversible systems.

What are the signs of a failing 034G0508 expansion valve?

Common indicators include erratic superheat readings, "hunting" (rapid fluctuations in pressure), or the valve failing to close completely (migration of refrigerant during standstill). Ensure the driver is calibrated before replacing the hardware.


Engineering & Installation Guide

  • Brazing Protocol: During installation, the valve body must be protected against excessive heat. Use a wet cloth or heat-sink paste to wrap the valve body, ensuring the internal temperature does not exceed 100 deg C. Direct flame contact with the motor housing will cause permanent internal seal failure.

  • Mounting Orientation: For optimal oil return and to prevent liquid slugging within the valve mechanism, install the valve with the actuator pointing upwards (within 90 degrees of vertical). Avoid installing the valve upside down as this promotes the accumulation of debris in the motor compartment.

  • Wiring & Noise Suppression: Use shielded cables for the stepper motor connection if the distance to the controller exceeds 3 meters. Ensure the shield is grounded only at the controller end to prevent ground loops, which can cause "missed steps" in the motor and lead to inaccurate flow control.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Denmark
Power source
AC-powered

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...