Danfoss

Danfoss 060G2101 AKS 33 Pressure Transmitter

SKU 060G2101

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2101

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 157g

  • Shipping port: Xiamen

  • Warranty: 12 months

The Danfoss 060G2101 is a high-precision AKS 33 Pressure Transmitter designed for use in refrigeration, air conditioning, and industrial process control applications. It provides a reliable 4–20 mA output signal based on measured pressure, offering excellent accuracy and long-term stability even in harsh, cold, or high-vibration environments.

Features

  • Wide Temperature Range: Operates reliably in ambient and medium temperatures from -40 to 85 degC.
  • Sealed Gauge Reference: Ensures consistent measurement regardless of atmospheric pressure variations.
  • Robust Construction: IP65 enclosure rating protects against dust and water spray.
  • Standardized Output: Compatible with standard industrial analog input controllers (4–20 mA).
  • High Overload Capacity: Withstands pressures up to 33 bar (479 psi).

Applications

  • Air conditioning systems
  • Refrigeration cabinets and cold storage
  • Heat pump systems
  • Industrial pressure monitoring
  • OEM process automation

Technical Specifications

Parameter Specification
Manufacturer Danfoss
Model AKS 33
Part Number 060G2101
Output Signal 4 to 20 mA (Current)
Pressure Reference Sealed gauge
Max. Overload Pressure 33 bar (479 psi)
Ambient Temp. Range -40 to 85 degC
Medium Temp. Range -40 to 85 degC
Compensated Temp. Range -30 to 40 degC
Electrical Connection Angular connector (EN 175301-803-A)
Enclosure Rating IP65
Net Weight 0.157 Kg
Shipping Weight 1 Kg

Installation Guidelines

  • Mounting: Install the AKS 33 in a location that minimizes vibration and protects it from direct exposure to corrosive substances. The transmitter can be mounted in any orientation.
  • Electrical Connection: Use the included EN 175301-803-A angular connector. Ensure the cable entry is sealed properly to maintain the IP65 ingress protection rating.
  • Wiring: Connect the 4–20 mA loop according to the specific controller requirements. Ensure that the polarity is correct (+ and -) as indicated on the terminal block inside the connector.
  • Maintenance: Do not attempt to open the hermetically sealed sensing element. Periodically inspect the electrical connector for moisture or corrosion, especially in high-humidity refrigeration environments.

FAQ

What is the primary pressure reference for the 060G2101?

The AKS 33 060G2101 uses a sealed gauge reference, which means it measures pressure relative to a sealed internal chamber, independent of ambient atmospheric pressure changes.

Can this transmitter be used in low-temperature refrigeration systems?

Yes, the transmitter is designed for medium temperatures as low as -40 degC, making it suitable for most refrigeration and HVAC applications.

What standard is the electrical connector compliant with?

The electrical connection complies with the EN 175301-803-A standard, commonly referred to as the DIN 43650-A connector.

What is the maximum overload pressure of this unit?

The maximum overload pressure is 33 bar (479 psi).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.