Danfoss

Danfoss 060G2101 AKS 33 Pressure Transmitter

SKU 060G2101

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2101

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 157g

  • Shipping port: Xiamen

  • Warranty: 12 months

The Danfoss 060G2101 is a high-precision AKS 33 Pressure Transmitter designed for use in refrigeration, air conditioning, and industrial process control applications. It provides a reliable 4–20 mA output signal based on measured pressure, offering excellent accuracy and long-term stability even in harsh, cold, or high-vibration environments.

Features

  • Wide Temperature Range: Operates reliably in ambient and medium temperatures from -40 to 85 degC.
  • Sealed Gauge Reference: Ensures consistent measurement regardless of atmospheric pressure variations.
  • Robust Construction: IP65 enclosure rating protects against dust and water spray.
  • Standardized Output: Compatible with standard industrial analog input controllers (4–20 mA).
  • High Overload Capacity: Withstands pressures up to 33 bar (479 psi).

Applications

  • Air conditioning systems
  • Refrigeration cabinets and cold storage
  • Heat pump systems
  • Industrial pressure monitoring
  • OEM process automation

Technical Specifications

Parameter Specification
Manufacturer Danfoss
Model AKS 33
Part Number 060G2101
Output Signal 4 to 20 mA (Current)
Pressure Reference Sealed gauge
Max. Overload Pressure 33 bar (479 psi)
Ambient Temp. Range -40 to 85 degC
Medium Temp. Range -40 to 85 degC
Compensated Temp. Range -30 to 40 degC
Electrical Connection Angular connector (EN 175301-803-A)
Enclosure Rating IP65
Net Weight 0.157 Kg
Shipping Weight 1 Kg

Installation Guidelines

  • Mounting: Install the AKS 33 in a location that minimizes vibration and protects it from direct exposure to corrosive substances. The transmitter can be mounted in any orientation.
  • Electrical Connection: Use the included EN 175301-803-A angular connector. Ensure the cable entry is sealed properly to maintain the IP65 ingress protection rating.
  • Wiring: Connect the 4–20 mA loop according to the specific controller requirements. Ensure that the polarity is correct (+ and -) as indicated on the terminal block inside the connector.
  • Maintenance: Do not attempt to open the hermetically sealed sensing element. Periodically inspect the electrical connector for moisture or corrosion, especially in high-humidity refrigeration environments.

FAQ

What is the primary pressure reference for the 060G2101?

The AKS 33 060G2101 uses a sealed gauge reference, which means it measures pressure relative to a sealed internal chamber, independent of ambient atmospheric pressure changes.

Can this transmitter be used in low-temperature refrigeration systems?

Yes, the transmitter is designed for medium temperatures as low as -40 degC, making it suitable for most refrigeration and HVAC applications.

What standard is the electrical connector compliant with?

The electrical connection complies with the EN 175301-803-A standard, commonly referred to as the DIN 43650-A connector.

What is the maximum overload pressure of this unit?

The maximum overload pressure is 33 bar (479 psi).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...