Danfoss

Danfoss 060L313066 KPS80 Temperature Control

SKU 060L313066

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060L313066

  • Country of origin:United States

  • Product Type: Temperature Switch

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Danfoss 060L313066 is a KPS80 series temperature control unit engineered for robust monitoring and regulation in demanding industrial environments. This temperature switch features an adjustable differential and is equipped with a 5000 mm capillary tube, providing flexibility for remote sensing applications. Designed for high reliability, the unit utilizes an adsorption charge and includes an SPDT gold contact configuration, making it suitable for low-current control circuits as well as standard switching operations. The housing is protected with armoring and includes a metal cable gland with a Pg 13.5 screwed cable entry for secure electrical connection.

Features

  • Model: KPS80 Temperature Control
  • Sensing Range: 70 to 120 degC
  • Capillary Tube Length: 5000 mm
  • Contact Configuration: SPDT Gold
  • Enclosure Protection: Armoring included
  • Electrical Connection: Screwed cable entry (Pg 13.5)
  • Connection Type: M 18 x 1.5 for pocket or hose
  • Charge Type: Adsorption

Applications

  • Industrial boilers and heat exchangers
  • Marine cooling and heating systems
  • Process plant temperature monitoring
  • Hydraulic power units
  • Compressor temperature regulation

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model 060L313066
Temperature Range 70 to 120 degC
Ambient Temperature -40 to 70 degC
Capillary Tube Length 5000 mm
Differential Type Adjustable
Contact Rating (AC1) 10 A, 440 V
Contact Rating (AC3) 6 A, 440 V
Contact Rating (AC15) 4 A, 440 V
Contact Rating (DC13) 12 W, 220 V
Gold Contact Range 1 to 30 mA, 5 to 30 V
Weight 2.5 Kg

Installation Guidelines

  • Mounting: Ensure the sensing element is installed in a location representative of the process temperature. Secure the capillary tube to prevent mechanical damage or excessive vibration.
  • Connection: The M 18 x 1.5 connection is designed for use with a thermowell (pocket) or hose to ensure accurate temperature transfer and environmental sealing.
  • Cable Entry: Utilize the provided Pg 13.5 metal cable gland to maintain the integrity of the electrical connection against dust and moisture.
  • Calibration: Adjust the temperature setting and differential according to the specific requirements of the process loop.
  • Ambient Limits: Ensure the ambient temperature of the control housing remains within the -40 degC to 70 degC range. Note that the unit can withstand 80 degC for a maximum of 120 minutes.

FAQ

What is the primary application for the gold contacts in this unit?

The SPDT gold contacts are specifically designed for low-current applications, typically ranging from 1 mA to 30 mA at 5 V to 30 V, ensuring reliable switching in sensitive control circuits.

Can this unit withstand ambient temperatures above 70 degC?

The operating ambient temperature range is -40 degC to 70 degC. It can withstand a maximum of 80 degC for up to 120 minutes.

Does this model include a protection pocket?

The unit features an M 18 x 1.5 connection for a pocket or hose, but the pocket itself must be sourced according to specific installation requirements.

What is the function of the adsorption charge?

The adsorption charge is the sensing medium inside the capillary system that reacts to temperature changes to actuate the switch contact.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...