Danfoss

Danfoss 061B100866 Pressure Switch

SKU 061B100866ÿ

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 061B100866ÿ

  • Country of origin:United States

  • Product Type: Pressure Switch

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Danfoss 061B100866 (061B100866) is a precision-engineered pressure switch designed for rigorous monitoring and control of gaseous and liquid media in industrial systems. Built around a durable bellows pressure sensing element, this unit provides reliable actuation within a specific pressure range of -0.20 to 1.00 bar. It is a critical component for safeguarding pumps, compressors, and hydraulic circuits in sectors such as water treatment, HVAC, and chemical processing. Its compact design and high ingress protection rating ensure sustained performance, effectively mitigating the risk of system failures caused by pressure irregularities.

Technical Configuration

This pressure switch features a robust mechanical architecture suited for harsh industrial environments. The pressure connection utilizes the standardized G-type interface, ensuring compatibility with most common industrial manifolds and piping systems. The electrical integration is facilitated via a Pg 11 cable entry, allowing for secure, weather-tight connectivity. The internal bellows assembly is calibrated for high sensitivity, offering precise switching logic that remains stable despite fluctuating process conditions. The IP65 enclosure provides full protection against dust ingress and low-pressure water jets, making it suitable for both indoor and outdoor installations where moisture or airborne contaminants are prevalent.

Technical Specifications

Feature Specification
Model 061B100866
Brand Danfoss
Setting Range -0.20 - 1.00 bar
Sensing Element Bellows
Connection Type G
Electrical Connection Pg 11
Enclosure Rating IP65
Weight 1.5 kg

FAQs

What media is this pressure switch compatible with?

The bellows-based sensing element is designed for use with non-corrosive liquids and gases. Please consult the chemical compatibility chart if the medium contains aggressive substances.

Is the switching point adjustable in the field?

Yes, the 061B100866 allows for adjustment within its specified range to suit the requirements of your specific application.

Can this unit be installed in high-vibration areas?

The device is designed for industrial use, but in areas with extreme mechanical vibration, it is recommended to mount the unit on an isolated bracket or use flexible pressure hoses to prevent fatigue.

Why is an IP65 rating important for this application?

The IP65 rating confirms that the housing is dust-tight and protected against water jets, ensuring the electrical contacts remain free from oxidation and shorts in wet or dusty plant environments.

Installation and Operational Guidelines

  • System Integration: When installing, ensure the pressure connection is tightened to the manufacturer's specified torque to avoid leaks. Always use appropriate thread sealant compatible with the application medium to ensure a hermetic seal.
  • Electrical Setup: Utilize the Pg 11 cable gland correctly to maintain the IP65 seal. Ensure that the electrical cable is secured with a strain relief to prevent pulling force from being transferred directly to the internal switch terminals.
  • Preventive Maintenance: Periodically verify the set-point accuracy against a calibrated reference gauge. During maintenance, inspect the bellows housing for any signs of mechanical deformation or corrosion that could impede the travel of the pressure-sensing element.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...