Danfoss

Danfoss 080G0294 MMIGRS2 CANBUS Control Panel

SKU 080G0294ÿ

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 080G0294ÿ

  • Country of origin:Denmark

  • Product Type: Control Panel

  • Payment: T/T, Western Union

  • Weight: 185g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 080G0294 (080G0294) is a high-performance Danfoss MMIGRS2 series remote display and control interface designed for the MCX programmable controller range. In complex industrial environments such as commercial HVAC systems, large-scale refrigeration plants, and district heating stations, this unit functions as the primary Human-Machine Interface (HMI). By providing real-time data visualization and parameter adjustment via a robust CANBUS communication link, the MMIGRS2 ensures that technicians can maintain peak system efficiency, significantly reducing diagnostic time and preventing unplanned downtime in mission-critical thermal management applications.

Technical Configuration

The 080G0294 architecture is centered around seamless integration with the Danfoss MCX ecosystem. Utilizing the CANBUS (CANopen) protocol, it allows for high-speed data exchange over long distances between the controller and the user interface.

  • Logic Integration: Built-in 2 Digital Inputs and 1 Digital Output allow the panel to act as a localized control node, capable of triggering alarms or receiving remote start/stop signals independent of the main controller's onboard I/O.

  • Visual Interface: The LCD display is optimized for industrial legibility, providing clear feedback on system variables, setpoints, and active alarms.

  • Universal Power Compatibility: The hardware supports both 24 VAC and 24 VDC power supplies, offering flexibility for various control cabinet power architectures (50/60 Hz).

  • Programmability: As a programmable controller accessory, its interface can be customized using Danfoss software tools to match specific application requirements.

Technical Specifications

Feature Specification
Model 080G0294
Brand Danfoss
Part Type Control Panel (MMIGRS2)
Communication Protocol CANBUS
Supply Voltage 24 VAC / 24 VDC
Digital Inputs (DI) 2 pc
Digital Outputs (DO) 1 pc
Frequency 50/60 Hz
Mounting Method Panel Mounting
Display Type LCD
Operating Temperature -20 to 55 deg C
Product Weight 0.185 kg
Shipping Weight 1.5 kg

Technical FAQs

Is the 080G0294 hot-swappable on an active CANBUS network?

While CANBUS is robust, it is recommended to power down the specific branch before connecting the MMIGRS2 to avoid voltage spikes or bus errors that could disrupt the communication of other nodes on the network.

How do I address the MMIGRS2 if multiple panels are on the same bus?

The unit's node ID must be uniquely configured within the MCX software environment. Ensure that the baud rate matches the master controller and that proper termination resistors are used if this is the end-of-line device.

What is the maximum cable distance for the CANBUS connection?

The distance depends on the baud rate; however, for standard industrial applications, distances up to 500 meters are achievable with high-quality shielded twisted-pair cabling, provided the signal integrity is maintained.


Engineering & Installation Guide

  • CANBUS Wiring Integrity: Always use shielded twisted-pair cable for the CANBUS connection. The shield should be grounded at a single point (typically at the main controller) to prevent ground loops while protecting the data signal from Electro-Magnetic Interference (EMI) generated by nearby VFDs or heavy contactors.

  • Panel Sealing: When performing panel mounting, ensure the gasket is seated correctly against the cutout. In environments with high humidity or airborne contaminants, an airtight seal is critical to prevent moisture ingress into the internal LCD electronics, which can lead to "ghosting" or logic failure.

  • Termination Resistors: If the 080G0294 is the last node in your physical network chain, a 120 Ohm termination resistor must be installed across the CAN-H and CAN-L terminals to prevent signal reflection and data corruption.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Denmark
Power source
AC-powered DC Power

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.