Danfoss

Danfoss KPS79 060L312266 Pressure Switch and Thermostat

SKU KPS79 060L312266

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L312266

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

The KPS79 060L312266 is a robust Pressure switch and Thermostat KPS unit designed for demanding industrial temperature control applications. This device provides reliable thermal regulation within a specific adjustment range, suitable for integration into complex industrial systems requiring high durability and precise thermal sensing. It features a capillary tube length of 6 meters and is engineered to withstand high sensor temperatures, ensuring operational stability in harsh environments.

Features

  • Wide temperature adjustment range for versatile industrial control
  • Adjustable mechanical differential for customized switching sensitivity
  • High maximum sensor temperature tolerance for extreme conditions
  • Long 6 meter capillary tube for flexible remote sensing installations
  • Durable construction designed for high-vibration and demanding media environments

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Number 060L312266
Model KPS79
Product Type Pressure switch and Thermostat
Setting Range 50 – 100 degC
Mechanical Differential 4 – 16 degC
Max. Sensor Temperature 200 degC
Capillary Tube Length 6 m
Suitable Sensor Pocket Length 110 mm / 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the unit is installed in a location that minimizes exposure to excessive mechanical shock or vibration. Use appropriate mounting hardware to secure the switch housing.
  • Capillary Management: Route the 6 m capillary tube carefully to avoid sharp bends, kinking, or contact with sharp edges, which could cause leaks or measurement inaccuracies.
  • Sensor Pocket: Use an appropriate sensor pocket (110 mm or 160 mm) to protect the sensing element from direct contact with high-pressure or corrosive media.
  • Calibration: Adjust the setting range and mechanical differential according to the specific application requirements using the provided adjustment interfaces.
  • Environment: Ensure the ambient operating conditions comply with the rated limits of the KPS series to prevent long-term degradation of the internal components.

FAQ

What is the temperature setting range for the KPS79?

The setting range for this unit is 50 degC to 100 degC.

What is the length of the capillary tube?

The KPS79 unit is equipped with a 6 meter capillary tube.

What is the maximum sensor temperature tolerance?

The sensor can withstand temperatures up to 200 degC.

Is the mechanical differential adjustable?

Yes, the mechanical differential is adjustable between 4 degC and 16 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...