Danfoss

Danfoss KPS79 060L312266 Pressure Switch and Thermostat

SKU KPS79 060L312266

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L312266

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

The KPS79 060L312266 is a robust Pressure switch and Thermostat KPS unit designed for demanding industrial temperature control applications. This device provides reliable thermal regulation within a specific adjustment range, suitable for integration into complex industrial systems requiring high durability and precise thermal sensing. It features a capillary tube length of 6 meters and is engineered to withstand high sensor temperatures, ensuring operational stability in harsh environments.

Features

  • Wide temperature adjustment range for versatile industrial control
  • Adjustable mechanical differential for customized switching sensitivity
  • High maximum sensor temperature tolerance for extreme conditions
  • Long 6 meter capillary tube for flexible remote sensing installations
  • Durable construction designed for high-vibration and demanding media environments

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Number 060L312266
Model KPS79
Product Type Pressure switch and Thermostat
Setting Range 50 – 100 degC
Mechanical Differential 4 – 16 degC
Max. Sensor Temperature 200 degC
Capillary Tube Length 6 m
Suitable Sensor Pocket Length 110 mm / 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the unit is installed in a location that minimizes exposure to excessive mechanical shock or vibration. Use appropriate mounting hardware to secure the switch housing.
  • Capillary Management: Route the 6 m capillary tube carefully to avoid sharp bends, kinking, or contact with sharp edges, which could cause leaks or measurement inaccuracies.
  • Sensor Pocket: Use an appropriate sensor pocket (110 mm or 160 mm) to protect the sensing element from direct contact with high-pressure or corrosive media.
  • Calibration: Adjust the setting range and mechanical differential according to the specific application requirements using the provided adjustment interfaces.
  • Environment: Ensure the ambient operating conditions comply with the rated limits of the KPS series to prevent long-term degradation of the internal components.

FAQ

What is the temperature setting range for the KPS79?

The setting range for this unit is 50 degC to 100 degC.

What is the length of the capillary tube?

The KPS79 unit is equipped with a 6 meter capillary tube.

What is the maximum sensor temperature tolerance?

The sensor can withstand temperatures up to 200 degC.

Is the mechanical differential adjustable?

Yes, the mechanical differential is adjustable between 4 degC and 16 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.