Delta Electronics

Delta AH10PFBS-5A PROFIBUS-DP Slave Network Module

SKU AH10PFBS-5A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics

  • Product No.: AH10PFBS-5A

  • Country of origin:United States

  • Product Type: Network Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Delta AH10PFBS-5A is a specialized network module designed for the AH500 series PLC systems, functioning as a high-performance PROFIBUS-DP slave module. This module enables seamless integration of the Delta PLC into a PROFIBUS-DP network, supporting both DPV0 and DPV1 communication standards to ensure compatibility with a wide range of industrial master controllers.

Engineered for efficiency and reliability, the AH10PFBS-5A offers a maximum transmission speed of up to 12 Mbps. It features a configurable I/O capacity of 100 words for both input and output data, providing sufficient throughput for complex process control tasks. The module is built with an integrated diagnostic function and a status LED indicator, allowing for quick system monitoring and simplified troubleshooting. Additionally, it supports hotswapping, ensuring that the module can be replaced or serviced without interrupting the operation of the main control system.

Features

  • Module Type: PROFIBUS-DP slave module
  • Communication Standards: Supports DPV0 and DPV1
  • Data Transmission: Max speed up to 12 Mbps
  • I/O Capacity: 100 words input / 100 words output
  • Maintenance: Supports hotswapping functionality
  • Diagnostics: Integrated diagnostic function and status LED indicators
  • Power Consumption: 1 W (Internal)

Applications

  • Distributed I/O systems in factory automation
  • Integration of PLC systems into existing PROFIBUS-based plant networks
  • High-speed industrial communication between master controllers and slave devices
  • Process monitoring and control in decentralized architectures

Technical Specifications

Feature Specification
Manufacturer Delta
Model AH10PFBS-5A
Product Type Network Module
Power Consumption (Internal) 1 W
Communication Interface PROFIBUS-DP Slave
Max Speed 12 Mbps
Input Capacity 100 words
Output Capacity 100 words
Shipping Weight 2 kg

Installation Guidelines

  • Module Insertion: Ensure the AH10PFBS-5A is properly seated in the PLC backplane slot. The hotswapping feature allows for installation while the system is powered, but always verify system requirements before proceeding.
  • Network Wiring: Use high-quality, shielded PROFIBUS cables to prevent signal degradation and electromagnetic interference at 12 Mbps speeds.
  • Termination: Ensure the PROFIBUS-DP network segment is correctly terminated at both ends to maintain signal integrity.
  • Diagnostics: Use the status LED indicators to verify communication activity. Refer to the PLC diagnostic tools to interpret fault codes if the status LED indicates an error.
  • Configuration: Configure the master controller to recognize the slave module I/O parameters (100 words input/output) within the PLC programming environment.

FAQ

Does the AH10PFBS-5A support DPV1 communication?

Yes, this module supports both DPV0 and DPV1 communication standards.

What is the maximum speed supported by this module?

The module supports a maximum transmission speed of 12 Mbps.

Is the AH10PFBS-5A hotswappable?

Yes, the module supports hotswapping, allowing for replacement without system downtime.

What is the I/O capacity of this slave module?

It is configurable for 100 words of input and 100 words of output data.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.