Delta Electronics

Delta VFD055E43A VFD-E Variable Frequency Drive

SKU VFD055E43A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics

  • Product No.: VFD055E43A

  • Country of origin:United States

  • Product Type: VFD-E Variable Frequency Drive

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The VFD055E43A (VFD 055E43A) is a high-performance, sensorless vector control AC drive belonging to Delta's versatile VFD-E series. Engineered for a 5.5 kW (7.5 HP) motor capacity, this standard version drive operates on a 460 V three-phase input, making it a staple in industrial power systems. In heavy-duty applications such as textile machinery, wastewater treatment pumps, and conveyor systems, the VFD055E43A provides superior torque control and precise speed regulation. Its modular design allows for flexible extension through optional fieldbus cards, while the integrated PLC functionality enables users to execute simple logic sequences, effectively reducing the need for external controllers and minimizing system footprint.

Technical Configuration

The VFD055E43A architecture is built around a "Micro" design philosophy that does not compromise on power. As a standard "A" version drive, it features a built-in EMI filter (for specific regions) and an integrated RFI switch for noise suppression. The drive utilizes advanced Fan Cooling to maintain optimal thermal performance during continuous operation. One of its most significant technical advantages is the side-by-side installation capability, facilitated by its high-efficiency heat dissipation system, which saves valuable cabinet space. The unit supports multiple communication protocols and features a modular I/O extension system, allowing for the addition of relay cards, encoder feedback, or analog expansion as required by the specific automation task.

Technical Specifications

Feature Specification
Model VFD055E43A
Brand Delta
Series VFD-E (Sensorless Vector Control)
Motor Capacity 5.5 kW / 7.5 HP
Input Voltage Three-Phase 460 VAC (380 V to 480 V)
Output Frequency 0.1 to 600 Hz
Control Mode V/f Control, Sensorless Vector Control (SVC)
Overload Capacity 150 percent of rated current for 60 seconds
Cooling Method Forced Air Cooling (Fan)
Integrated PLC 500 Steps
Protection Rating IP20
Weight 4.2 kg (6 kg shipping weight)
Dimensions Standard VFD-E Frame Size (approx. 130 mm x 250 mm x 170 mm)

Technical FAQs

Can the VFD055E43A handle high-starting torque applications?

Yes. With its Sensorless Vector Control (SVC) mode, the drive can provide significant starting torque (up to 150 percent at 1 Hz), making it suitable for loads that are difficult to start, such as loaded conveyors or mixers.

Does this drive require an external PLC for simple automation logic?

The VFD055E43A features a built-in PLC with a 500-step capacity. This allows users to program basic timing, interlocking, and sequence logic directly within the drive using Delta’s software, often eliminating the need for a small external PLC.

How is the "Standard Drive" version different from specialized versions?

The "A" suffix denotes the standard hardware configuration, which includes the basic I/O and standard interface. It is the most versatile model, suitable for the vast majority of industrial speed control applications without needing specialized firmware.


Engineering & Installation Guide

  • Side-by-Side Mounting: The VFD-E series supports high-density mounting. When installing multiple units, ensure the ambient temperature does not exceed 40 deg C for side-by-side configurations. If the temperature is higher, maintain at least a 50 mm gap between drives or provide supplemental cabinet cooling.

  • Harmonic Mitigation: For 460 V applications, especially in facilities with sensitive electronics, it is highly recommended to install an AC line reactor at the input of the VFD055E43A. This reduces harmonic distortion back to the mains and protects the drive's DC bus capacitors from voltage surges.

  • Grounding and EMI: Ensure the drive is grounded to a common star point. The motor cable should be shielded, and the shield should be grounded at both the drive and the motor end to minimize radio frequency interference (RFI) that could impact nearby sensor signals.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...